Saxby IM 103174 ShieldSlim CCT LED Fixed Downlight Instruction Manual
- June 13, 2024
- saxby
Table of Contents
Saxby IM 103174 ShieldSlim CCT LED Fixed Downlight
Product Information
The ShieldSLIM 4CCT light fitting is a high-quality product designed for safe and satisfactory operation. It is suitable for use in various settings, including bathrooms. The product features a 7W LED module (SMD) with a color temperature of 2700/3000/4000/6000K. It is energy-efficient, with an energy efficiency class of E. The light source in this product is non-replaceable, but the control gear can be replaced by a professional if needed. It conforms to all relevant UKCA Directive and EC Directive requirements, ensuring its compliance with safety standards. The power supply is double insulated, eliminating the need for an Earth-circuit connection. The light fitting is fire-rated for up to 90 minutes, providing extra safety measures. It has an IP65 rating, making it suitable for use in damp environments. The product is also dimmable, allowing you to adjust the lighting according to your preference. For care and safety, it is recommended to clean the light fitting with a soft dry cloth, avoiding solvents or abrasive cleaners that may damage the finish. Always switch off the power supply before cleaning. Please note that waste electrical products should not be disposed of with household waste. Check with your Local Authority or local store for recycling advice.
Product Usage Instructions
- Before starting the installation, make sure to read and understand the instructions provided.
- Ensure that the mains supply cable has a minimum cross-section area of 1.0mm2.
- Plan the desired layout of the light fittings, considering the distances between the transformer and each fitting.
- Avoid positioning cables and junction boxes in areas where they may be at risk of damage.
- Use suitable conduit or plastic trunking to protect the cables.
- Mount the unit a minimum distance of 50mm from a joist.
- Ensure a minimum distance of 0.5m between units.
- Place the product out of arm’s reach.
- If installing in a bathroom, refer to the provided diagram to determine the suitable zones for installation.
- If installing in a room zone 1 containing a bath or shower, use a 30mA RCD in accordance with IEE regulations.
- Before installation, remove any existing fittings and carefully note the position of each set of wires.
- Make sure the ceiling surface is flat and smooth for proper fitting.
- Ensure that all screws and cable entry points are sealed to maintain the IP rating of the product.
For further information, please refer to the instruction manual provided with the product or visit https://www.lighting-info.co.uk/103174.
Important: Always follow safety guidelines and regulations when working with electrical installations. If unsure, consult a professional electrician for assistance.
Wiring
Unclip the cover from the quick fit connection block at the end of the driver. Having correctly identified the wiring form your existing light fitting, pull the mains wire through the hole and connect to the connection block inside the quick fit connection case in the following way.
Check that…
You have correctly identified the wires. The connections are tight. No loose
strands have been left out of the connection block.
Technical data
- Supply Voltage: 220-240 V~, 50 Hz
- Bulb Type: 7W LED module (SMD) CCT, 2700/3000/4000/6000K This product contains a light source of energy efficiency class E.
Non-replaceable light source
Replaceable control gear by a professional
Conformity with all relevant UKCA Directive requirements.
Conformity with all relevant EC Directive requirements.
The power supply is Double Insulated and does not require connection to an
Earth circuit.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your Local Authority or
local store for recycling advice.
This product is suitable for dimming.
This product fire rated to 90 minutes.
This product is rated at IP65.
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is double insulated and does not require connection to an
earth circuit.
Please read these instructions carefully before commencing any work This unit must be fitted by a competent and qualified electrician. Install in accordance with the IEE Wiring regulations and current Building Regulations. Check the pack and make sure you have all the parts listed. This system operates at Safety Extra Low Voltage, via the supplied LED driver, Never connect the light fittings directly to the mains without using the supplied LED driver. Always disconnect the LED driver from the mains when installing or maintaining this system. To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified electrician. This light fitting should be connected to a fused circuit. If replacing an existing fitting, make a careful note of the connections. This product complies with Building Regulations Part B and is suitable for use in 90 minutes fire rated ceiling. This product is suitable for covering with insulation 270mm. This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped. Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.
Layout
- Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between the transformer and each light fitting.
- Avoid locating any cables in positions that would cause a hazard. Position cables and junction boxes (not supplied) away from areas where they may be at risk from being cut, trapped or damaged.
- The mains supply cable must have a minimum cross section area of 1.0mm2.
- Cables must be protected using suitable conduit or plastic trunking.
- The unit must be located a minimum distance of 50mm from a joist.
- The distance between units must be 0.5m minimum. 2.25m Zone 1 0.6m Outside zones
- This product must be mounted out of arms reach.
- This product is suitable for use zone 2 and outside zones in a bathroom. Please see diagram. 0.6m
- If this unit is being fitted in a room zone 1 containing a bath or shower, a 30mA RCD must be used – in accordance with
- IEE regulations.
Installation
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires. The ceiling surface must be flat and smooth to ensure a good fit. Note that the switch is turned off before installation. Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
The colour is changeable between 2700/3000/4000/6000K using the CCT Switch
under the bezel before installation.
Note: Befeore you change the colour, please turn off the power switch for
safety.
- Cut a mounting hole 68mm diameter in the ceiling taking care not to foul any pipes, mains cables or joists beneath the surface (Ref. Fig.1). It is always recommended to cut the hole slightly smaller than the size specified, and then file the hole until the recessed unit fits snugly. Ensure a minimum ceiling void depth of 48mm is available.
- Open the terminal block cover, Connect the mains supply cable into the terminals (Ref. Fig. 2).
- Push the spring clips upwards and fit into the ceiling hole, then push the unit up until firmly in position, ensuring that no cables are trapped. (Ref. Fig. 4).
- Ensure that the product is sitting properly in the hole.
- Switch on. Your light is now ready for use.
Optional Colour Bezels
There are four optional colour bezels – 90377 (Satin Nickel), 90378 (Chrome),
92513 (Matt black) and 78418 (Antique brass). Rotate the fixed bezel one
quarter turn anticlockwise and pull it away from the luminaire. Select a new
bezel and rotate it one quarter turn clockwise back onto the front of the
luminaire. Do not remove the rubber seal from the rear of the luminaire outer
rim. Ensure that it is secure and correctly positioned to maintain the IP65
rating.
Care and Safety
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish. For your safety, always switch off the power supply before cleaning. For further information, please visit https://www.lighting-info.co.uk/103174
V5 10/05/2023
UK Manufacturer: BH17 7BY
EU Manufacturer: Brilliant AG,
Brilliantstrasse 1, D-27442 Gnarrenburg