goobay 59513 Local Air Conditioner User Manual

June 12, 2024
goobay

GOOBAY-LOGO

goobay 59513 Local Air Conditioner

goobay-59513-Local-Air-Conditioner-PRODUCT

Product Information

  • Product Name: Local Air Conditioner
  • Model Number: 59513
  • Power: 9000 BTU/2600 Watt
  • Features: The local air conditioner is equipped with a lithium button cell battery for the remote control. It comes with various safety features and has a maximum cooling capacity of 2.6 kW.

Technical Specifications:

  • Article Number: 59513
  • Model Number: FDP26-1080R5
  • Nominal Voltage / Frequency: 220-240 V / 50 Hz
  • Power Consumption: 950 W / 4.3 A
  • Sound Pressure Level: 54 dB(A)
  • Sound Power Level: 65 dB(A)
  • Weight: 507 g
  • Color: Gray

Product Usage Instructions

Safety Instructions

  • Make sure the power is disconnected before cleaning or servicing the air conditioner.
  • Use appropriate protective measures to prevent accidental use of the air conditioner when it is unplugged.
  • The remote control uses a replaceable lithium button cell battery. Handle it with care.

Description and Function

The local air conditioner is designed to cool a specific area and has a cooling capacity of 9000 BTU/2600 Watt.

Installation

  • Attach the hose adapter to one end of the exhaust hose by turning it counterclockwise.
  • Install the exhaust hose according to the provided instructions.
  • Use the window kit to seal the window opening and prevent hot air from entering the room.
  • Use the window cover to cover the remaining window opening.

Operation

  • Press the power button (ON/OFF) to turn on or off the air conditioner.
  • Use the function buttons and status indicators to control and monitor the air conditioner’s settings and operation.
  • The sleep mode, timer function, and automatic mode can be activated using the respective buttons.

Note: Please refer to the complete user manual for detailed instructions on installation, operation, and maintenance of the local air conditioner.

Safety instructions

Information regarding the user manual

The user manual is part of the product and contains important information for correct use.

Read the user manual completely and carefully before the userThe user manual must be available for uncertainties and passing the product. Keep this user manual.

Warning levels

The following signal words are used in this user manual to indicate dangers when operating the air conditioner. Be sure to observe and follow all warnings to avoid risks!

  • DANGER: Warnings against hazards that will result directly in serious injuries or death in case of non-observance.
  • WARNING:  Warnings against hazards that may result in serious injuries or death in case of non-observance.
  • CAUTION: Warnings against hazards that may result in injuries in case of non-observance.
  • NOTICE: Warnings against hazards that may result in material damage in case of non-observance.

Notes regarding the combustible refrigerant propane
****The air conditioner contains propane (R290) as a refrigerant.
Propane is a colorless, odorless gas with minimal global warming potential that complies with European environmental regulations on refrigerants. Improper handling or unforeseen events can lead to accidents or damage that cause gas to leak from the air conditioner.
The danger of an incident with severe consequences occurring is very minimal with an air conditioner of this size.
Propane in combination with air is highly combustible and can lead to an explosion.

  • Only operate and store the air conditioner in rooms with an area of 10 m² to avoid the danger of a concentration of flammable gas building up in the air. If the cooling circuit is leaking, the escaping propane can ignite.
  • If gas flows out of the air conditioner, call the fire brigade immediately! In this case, do not pull the mains plug and do not switch on or off any other electrical devices.
  • Do not damage the cooling circuit or any of its components. The gas is pressurized and can explode if heated.
  • Only install and operate the unit in accordance with national regulations.
  • Observe national gas regulations.
  • Do not use any medium to accelerate the thawing process.
  • The refrigerant levels outlined in the technical specifications (chapter 2.4) must not be exceeded. Propane that is on fire cannot be extinguished with water.
  • Extinguish burning propane with a fire extinguisher containing alcohol-resistant foam, carbon dioxide (CO2) or extinguishing powder. Propane is colorless, odorless, and heavier than air. Leaking gas is very difficult to detect. Propane is mildly toxic. Inhaling high concentrations of propane can lead to poisoning.
  • Avoid the vicinity of leaking propane.
  • Immediately seek fresh air if you have inhaled propane. Propane removes a large amount of heat from its immediate vicinity as it leaks out from the air conditioner. Propane has the potential to burn the skin.
  • If you come into direct contact with propane, thoroughly rinse the area of contact with cold to lukewarm water.
  • If you receive burns or experience nausea due to propane, seek immediate medical attention.

Risk of electric shock

The product may cause an electric shock if it comes into contact with water.

  • Do not use the product with wet hands.
  • Do not use the product in the immediate vicinity of water, for example, in bathtubs, sinks or swimming pools.
  • Do not expose the product to direct streams of water.

Rain splashing on the product may cause an electric shock.

  • Do not place the product near an open window. Voltage-free only with pulled plug.

  • In case of emergency, after use, and during a thunderstorm, pull the mains plug out of the socket directly at the plug housing.

  • Do not pull the mains plug when propane is leaking from the air conditioner.

  • Do not open the housing.

  • Do not modify products and accessories.

  • Do not short-circuit connectors and circuits

  • Do not insert any objects or fingers into ventilation slots or connection sockets The unit must not be operated with a defective mains cable!

  • Check regularly that the appliance cable is still intact.

  • Only use the unit with the mains cable unwound.

  • Do not use the product if the cable is damaged.

  • Always hold the plug and not the cable when removing it from a socket.

  • Do not kink or stretch the main cable.

  • Use the product only with earthed sockets.

  • Compare the technical data of the product, mains, and peripheral devices.

  • These must be identical.

  • A defective device may not be put into operation but must be disconnected from mains and protected against further use.

  • Use product, product parts, and accessories only in perfect condition.

  • In case of questions, defects, mechanical damage, trouble, and other problems, non-recoverable For the documentation, contact your dealer or manufacturer.

  • Do not repair defective products yourself, but contact the dealer or the manufacturer.
    Risk of poisoning

  • Do not drink the condensate.
    Tripping hazard

  • Mind placing cables in a way that they do not form obstacles and cannot be damaged.
    Operation and storage conditions

  • NEVER leave the product unattended while in operation.

  • Do not cover the product.

  • Keep all ventilation slots free.

  • Make sure that the air inlet and air outlet are clear.

  • Make sure that the inlet side is free of dirt.

  • Do not operate the product in dusty environments or in areas with inadequate ventilation.

  • Do not operate the fan in the vicinity of explosive and/or flammable gases.

  • Do not operate the product in an explosive environment.

  • Do not place or operate the product near open flames, cooking appliances, or devices that generate heat such as radiators or stoves.

  • Keep the unit at least 1 meter away from televisions or radios to avoid electromagnetic interference- ce.

  • Place the product on a stable, level, dry and dust-free surface so that it cannot tip over during operation and the surface cannot be damaged by vibrations.

  • Place the unit on a flat surface with a slope of less than 5°.

  • Make sure that the product stands securely. The unit must not stand on the main cable to prevent it from tipping over during operation.

  • Avoid stresses such as heat and cold, moisture and direct sunlight, microwaves, vibrations, and mechanical pressure.

  • Switch off the unit and disconnect it from the mains when it is not in use, when cleaning it or when it malfunctions.

  • Store the product in a cool and dry place.

  • Do not sit on the product.

  • Do not place any objects on the product.

  • Observe the minimum distances to walls and objects when installing.

  • Only transport the unit if the condensate container is empty.

  • Allow the air conditioner to stand for at least 12 hours after each transport to allow the refrigerant to collect in the compressor.

Target group information

Service work such as maintenance, care, and troubleshooting may only be carried out in accordance with the manufacturer‘s instructions.

  • Observe the information in chap. 12 „Maintenance and care“.
  • Observe the information in chap. 14 „Faults and malfunctions“.

The entire refrigerant circuit is a hermetically sealed system that does not require maintenance and may only be repaired by companies that specialize in refrigerant and air conditioning technology. Maintenance work that requires opening the housing may only be performed by companies that specialize in refrigerant and air conditioning technology. The unit may only be repaired or serviced by an authorized specialist. Any person that works on a refrigerant circuit must be able to provide proof of a certificate of competency issued by an accredited authority. Not recommended for children and people with physical and/or mentally limited capabilities.

  • Secure the product against accidental use.
  • Secure packaging, small parts, and insulation against accidental use.

Battery hazards

The remote control is equipped with a lithium button cell. It can be replaced.

  • Keep batteries out of the reach of children. If swallowed, there is a risk of severe internal burns or even death. Seek immediate medical attention if you believe someone may have swallowed or otherwise ingested the battery.
  • Never use batteries when they are dented, leaked, or damaged.
  • Remove leaked, deformed, or corroded batteries from the product and dispose of them with appropriate protectives. If a battery has leaked, avoid contact with skin, eyes, and mucous membranes. If necessary, rinse affected areas with water and seek medical attention immediately.
  • Do not deform, burn or disassemble batteries and never puncture them with a sharp object. Extreme heat can lead to explosion and/or leakage of corrosive liquid. Mechanical damage can cause gaseous substances to escape, which can be highly irritating, flammable, or toxic.
  • Do not short-circuit batteries or immerse them in liquids. There is a risk of explosion, fire, heat, smoke, and/or gas development.
  • If the battery is accidentally dropped into water, remove it immediately Place the battery in a safe, open area and stay away until it is completely dry Do not reuse the dried battery, but dispose of it as indicated in chapter 15.2.

Description and function

Product

The product is a single duct air conditioner (local air conditioner) used for cooling, circulating, and dehumidifying room air. The air conditioner is mobile and can be conveniently transported and used in different rooms. The air conditioner can be controlled via a control panel or remote control and has a timer function.

Scope of delivery

  • Local air conditioner (9000 BTU/2600 Watt)
  • Exhaust hose
  • Hose adapter
  • Window insert
  • Adapter for window insert
  • Fixing screw
  • Fixing nut
  • Washer
  • Window cover
  • Velcro tape
  • Remote control
  • 1x lithium button cell (CR2025)
  • User manual

Operating elements and parts

goobay 59513 Local Mobile Air Conditioner - Operating elements and
parts

  1. Air outlet with cover
  2. Signal receiver
  3. Wheels
  4. Control panel
  5. Transport handle
  6. Mains cable with winder
  7. Air inlet with air filter
  8. An upper outlet for condensate with plug
  9. Air outlet for exhaust air
  10. A lower outlet for condensate with plug
  11. Remote control
  12. Battery compartment
  13. Window cover
  14. Velcro tape
  15. Hose adapter
  16. Exhaust hose
  17. Adapter for window insert
  18. Window insert
  19. Fixing nut
  20. Washer
  21. Fixing screw

Specifications

Article number 59513

Air conditioner
Model number| FDP26-1080R5
Cooling capacity| 2.6 kW / 9000 BTU
Rated voltage / frequency| 220-240 V ∼ / 50 Hz
Cooling input power| 950 W / 4.3 A
Pressure (outlet side)| 2.5 MPa
Pressure (inlet side)| 1.2 MPa
Sound pressure level L PA| 54 dB(A)
Sound power level LWA| 65 dB(A)
Protection class|
Protection level| IPO
Fuse| 250 V -N–, 3.15 A, Tor F
The rated capacity for cooling (P, med for cooling)| 2.6 kW
Rated power input for cooling (PEER) EE R)|  1.0 kW
Rated energy efficiency ratio (EER, $)| 3.
Power consumption in standby mode (Ps8)| 0.4 W
Electricity consumption of single duct
appliances for cooling (Qw)| 1.0 kWh/h
Global warming potential (GWP)| 3 kg CO2 eq.
Energy efficiency class| A
Dehumidification capacity| 1.1 I/h
Air flow volume| 350 m3/h
Area of use/room size| 10 – 20 m2
Cable length (incl. plug)| 1.8 m
Dimensions| 41.6 x 33 x 67.1 cm
Weight| 24 kg
Operating temperature| 15 °C -43 °C
Max. room humidity| 80%
Min. distance to walls and objects| 60 cm
Refrigerant
Type| Propane (R290)
Fill level| 185 g
Exhaust hose
Dimensions (0 x Length)| 15.5 x 31.5 – 200 cm
Weight I Colour| 520 g I white
Window insert
Dimensions| Length: 62 – 115 cm
Width: 11 cm
Height: 2 cm
Weight I Colour| 507 g I grey
Window cover
Dimensions| 400 x 38,5 cm
Weight I Colour| 155 g I white
Width | Length| 2.6 cm | 8 m
---|---
Weight | Colour| 90 g | white
Remote control
Type| Infrared
Input voltage| 3.0 V  **
Dimensions | Weight| 40 x 86 x 7 | 11 g
Range| 5 m
Battery
Type| Lithium button cell (CR2025)
Nominal voltage, Capacity| 3.0 V **
, 150 mAh
Weight| 3 g

Intended use

This product is intended exclusively for private use and its intended purpose. This product is not intended for commercial use. We do not permit using the device in other ways like described in chapter „Description and Function“ or in the „Safety Instructions“. Use the product only in dry interior rooms. Not attending to these regulations and safety instructions might cause fatal accidents, injuries, and damages to persons and property.
IPX0: This product is not protected against water.

Unpacking the device

NOTICE:  Material damage

Be careful when unpacking so as not to damage the air conditioner and the cooling circuit!

  1.  Open the carton.
  2. Remove the accessories and the air conditioner and set them down carefully.
  3. Check that the scope of delivery is complete and undamaged.
  4. Unwind the main cable completely and make sure that it is not damaged. Contact the dealer or manufacturer if you notice any damage or missing accessories.
  5. Compare the technical data of the product, power supply, and peripheral devices. These must be identical.

Transport

NOTICE:  Material damage

The air conditioner may be damaged if transported incorrectly.

  • Do not tilt the air conditioner more than 35°.
  • Only roll the air conditioner on flat surfaces.
  • Keep the original packaging for transport.
  • Place the air conditioner with special care so as not to damage the housing.

The air conditioner has wheels (3) and can be rolled over small distances if the surface is level. On uneven surfaces, on stairs, or over long distances, the air conditioner must be carried by at least 2 people.

Note: that there may be additional transport regulations for units with flammable refrigerant.

Before each transport

  • Switch off the air conditioner and pull the main cable out of the socket at the plug.
  • Empty the condensate container. During transport
  • Grip the air conditioner only by the transport handles (5).
  • Put on non-slip, sturdy gloves.
  • Do not pull on the main cable to move the air conditioner.
  • When transporting with a vehicle: position the air conditioner so that it cannot slide or fall over.

After each transport

  • Place the air conditioner in an upright position.
  • Allow the air conditioner to stand for at least 12 hours before operating it so that the refrigerant can collect in the compressor. Otherwise, the compressor may be damaged!

Assembly

If you want to use the air conditioner in the operating modes of cooling, dehumidification, and automatic, the exhaust hose (16) must be fitted in order for the exhaust air to be discharged from the room. No exhaust air is produced in the operating mode ventilation. Proceed as follows to fit the exhaust air hose to the air conditioner:

goobay 59513 Local Mobile Air Conditioner - Assembly1| 1. Pull the exhaust hose (16) apart at both ends Pay particular attention that the fins at the beginning and end of
the exhaust hose are fully unfolded.
---|---
| 2. Attach the hose adapter (15) to one end of the exhaust hose. To do this, turn the hose adapter about 3 to 4 times counterclockwise onto the exhaust hose.
The connection should be as airtight as possible.
| 3. Attach the adapter for the window insert (17) to the other end of
the exhaust hose. To do this, turn the adapter for the window insert about 3 to 4 times counterclockwise onto the exhaust air hose.
The connection should be as airtight as possible.
goobay 59513 Local Mobile Air Conditioner - Assembly4| 4. Attach the hose adapter to the air outlet for exhaust air (9) by pushing the hose adapter into the frame from
above.
The air conditioner is now assembled.

Set up and installation

Choosing the installation site

DANGER: Fire hazard
The air conditioner contains propane (R290) as a refrigerant. Propane in combination with air is highly combustible and can lead to an explosion.

  • Only operate and store the air conditioner in rooms with an area of 10 m² to avoid the danger of a concentration of flammable gas building up in the air.
  • Do not operate the air conditioner in rooms where there are sources of ignition (e.g. naked flames, electric heaters, gas appliances that are switched on). Choose the installation site for the air conditioner carefully. Consider the following aspects:
  • The room in which the air conditioner is installed and used should not exceed 20 m².
  •  There is a possibility of water dripping from the air conditioner (e.g. if an outlet for condensate is not properly closed).
  • A minimum distance of 60 cm from walls and objects must be maintained on all sides.
  •  Position the air conditioner at least 1 m away from televisions or radios to avoid electromagnetic interference.
  •  Do not use the unit with an extension cord or over an adapter.
  • Connect the mains cable with the mains plug directly to an earthed socket.
  • If you use the air conditioner in the operating modes of cooling, dehumidification, or automatic, it must be possible to route the exhaust hose so that the exhaust air can flow to the outside. Also observe the information in chapter 1 „Safety instructions“!

Laying the exhaust hose

The exhaust hose (16) is used to discharge the waste heat and humidity to the outside. There are various ways to install the exhaust hose. For example, it can be clamped in a door or window.
The end of the exhaust hose must then be secured so that it cannot slip.
If you route the exhaust air hose through a window, you should install the supplied window insert (18) or window cover (13) for efficient operation (see Chap. 7.3 or 7.4).
The hose should be laid as straight as possible or with an incline.
There should be no kinks in the exhaust hose. Kinks prevent the exhaust air from being discharged properly. Ejected air and condensate can accumulate and lead to malfunctions.
The exhaust hose should be as short as possible. The shorter the exhaust hose, the lower the energy consumption.
The supplied exhaust hose is matched to the unit. Do not replace or extend it with other hoses. Using the window insert
The window insert (18) is intended for use with sliding windows. The window insert seals open spaces and keep warm air and rain outside.

Assembling the window insert
The window insert (18) consists of two parts that slide against each other. One part has an opening for the exhaust air (left part) and the other part has a guide groove in the middle (right part). This allows you to freely adjust the width. The desired width is then fixed with the fixing nut (19), washer (20), and fixing screw (21).

  1.  Slide the two parts of the window insert apart.
  2. Slide the washer onto the fixing screw.
  3. Insert the fixing screw with the washer through the hole in the left part of the window insert. The fixing screw and the window insert should both lie horizontally in line.
  4.  Slide the two parts of the window insert onto each other. Slide the fixing screw with the washer into the guide groove in the right part of the window insert.
  5.  Set the desired width.
  6. Screw the fixing nut onto the fixing screw. The window insert is now assembled and looks something like this:

Installing the window insert

The window insert (18) can be used with both vertically and horizontally closing windows.

  1. Open the window.

  2. Insert the window insert into the window frame.

  3. Adjust the width of the window inserts a second time if necessary.goobay 59513 Local Mobile Air Conditioner - Installing the window insert CAUTION!  Risk of crushing!
    Fingers and limbs can be crushed.
    Do not hold fingers or limbs between the window, frame, or window insert.

  4.  Slide the window closed so that the window insert is wedged between the window and the frame. The window insert is now installed. There should be as little free space as possible on the sides of the window insert.

Clamp the end of the exhaust air hose with the window insert adapter (17) into the window insert. The exhaust air from the air conditioner is now discharged to the outside and the warm air is kept outside.

Using the window cover

The window cover (13) is intended for use with casement windows. It seals open spaces and keeps warm air and rain outside. The window cover can be used universally for casement windows with a circumference of up to 400 cm. The velcro tape (14) is needed to install the window cover.

Installing the window cover

  1.  Open the window.
  2.  Lay the velcro tape along the window frame and along the opened window. The velcro tape is self-adhesive and can be cut to size as required.
  3.  Attach the window cover to the window frame and to the open window using velcro tape. The straight side of the window cover (A) is attached to the window frame. The curved side of the window cover (B) is attached to the open window.
  4.  Move the zip to the place where the exhaust hose is to be positioned. The window cover is now installed.

Passing the exhaust hose through the window cover

  1.  Guide the exhaust hose (16) through the opening in the window cover.
  2. Secure the exhaust hose by closing the two zips. You can additionally use cable ties to reinforce the fastening (not included in the scope of delivery). The exhaust air from the air conditioner is now discharged to the outside and the warm air is kept outside.goobay 59513 Local Mobile Air Conditioner - window cover

Commissioning

NOTICE: Material damage

There is refrigerant in the air conditioner. When the air conditioner is moved, the refrigerant is dispersed. If the air conditioner is switched on in this condition, it may cause damage or loss of cooling capacity.

  • Allow the air conditioner to stand for at least 12 hours before operating it to allow the refrigerant to collect in the compressor.
  • Do not move the air conditioner during operation.
  1.  Plug the mains cable (6) into a free and easily accessible socket. Make sure that the cable is laid in such a way that it does not obstruct anyone and is not damaged.A signal tone sounds.
  2. Open the cover of the air outlet (1).
  3.  Make sure that the air inlets and outlets are clear.
  4.  Make sure that no objects (e.g. curtains) can be sucked in by the air inlets or obstruct the airflow.
  5. Make sure that the air filter (7) is correctly inserted and free of impurities. The air conditioner can now be switched on and used.

Function buttons and status indicators

The function buttons and status indicators are located on the control panel (4) of the air conditioner. The following illustration and table explain the function buttons and status indicators.

goobay 59513 Local Mobile Air Conditioner - Function buttons and status
indicators

Letter Designation Description
a Status indicator
SLEEP The status indicator lights up green when the SLEEP mode is active
b Status indicator
TIMER The status indicator flashes yellow while a timer is being set. The

status indicator lights up yellow when a timer is active.
c| Status display| The status display shows the temperature, timer duration, and error codes.
d| Status indicator for
strong fan| The status indicator lights up yellow when the strong fan is active.
e| Status indicator for
light fan| The status indicator lights up green when the light fan is active.
---|---|---
f| Status indicator
Ventilation| The status indicator lights up yellow when the ventilation operating mode is active (see chapter 11.1).
g| Status indicator
Dehumidification| The status indicator lights up green when the dehumidification operating mode is active (see chapter 11.1).
h| Status indicator
Cooling| The status indicator lights up green when the cooling operating mode is active (see chapter 11.1).
i| Status indicator
Automatic| The status indicator lights up green when the automatic operating mode is active (see chapter 11.1).
j| Status indicator
ON/OFF| The status indicator lights up red when the air conditioner is switched on.
k| | Press the button to switch the air conditioner on or off (see chapter 11.2).
l| Status indicator
LOCK| The status indicator lights up green when the child lock is active.
m| Button SLEEP| Press the button to activate or deactivate the SLEEP mode. SLEEP mode can only be activated in cooling mode.
In SLEEP mode, the light fan is set automatically. The set room temperature is increased by 1 °C after one hour, increased by
2 °C after 2 hours and the air conditioner switches itself off after 6 hours.
n| Button TIMER| Press the key to set the timer function (see chapter 11.6).
o| Button DOWN| Press the button to decrease the selected value (temperature, timer).
p| Button UP| Press the button to increase the selected value (temperature, timer).
q| Button SPEED| Press the button to set the fan level (see chapter 11.5).
r| Button MODE| Press the button to set the operating mode (see chapter 11.3).
s| Button LOCK| Press the button for about 5 seconds to activate or deactivate the child lock (see chapter 11.7).

Remote control

Activating the remote control

Pull the contact protector out of the battery compartment (12). The remote control is now activated.

Explanation of the buttons

Alternatively, you can also control the air conditioner via the remote control. The buttons on the remote control are explained below.

       goobay 59513 Local Mobile Air Conditioner - Explanation of the
buttons| Symbol| Designation| Description
---|---|---|---
| Button ON/OFF| Press the button to switch the air conditioner on or off.
| Button UP| Press the button to increase the selected value (temperature, timer).
| Button DOWN| Press the button to decrease the selected value (temperature, timer).
| Button TIMER| Press the key to set the timer function.
| Button MODE| Press the button to set the operating mode.
| Button SPEED| Press the button to set the fan level.
| Button SLEEP| Press the button to activate or deactivate the SLEEP mode.

Changing the battery

If necessary, replace the empty battery with a new one of the same type (See chapter 2.4)

  • Open the battery compartment (12) by pushing the small lever to the side and then pulling out the battery compartment.
  • Remove the empty battery.
  • Place the new battery in the battery compartment with the positive pole facing upwards.
  • Close the battery compartment again.
  •  Dispose of the empty battery properly. See also chapter 15.2.

Operation

Operating modes

The air conditioner can be used in four operating modes. The operating modes ventilation, dehumidification, cooling, and automatic are available. The air conditioner has internal memory. The temperature and fan speed settings in the operating modes are retained when you switch the air conditioner off and on again.

Ventilation
In ventilation mode, the room air is circulated. You can set the fan speed. No cooling or dehumidification takes place. In this operating mode, the room temperature is not affected.

Dehumidification
In dehumidification mode, the relative humidity is reduced. The air conditioner automatically runs through different cycles. In this operating mode, air should not be able to escape from the room (e.g. through an open window). The low fan speed is active and cannot be changed. In this operating mode, the room temperature is not affected.

Cooling
In the cooling operating mode, heat is extracted from the room air and the cooled air is fed back into the room. Part of the air, the extracted heat, and any condensate are discharged outside via the exhaust hose. In this operating mode, air should be able to flow in from an adjacent room, for example through a door gap. The fan speed and the desired room temperature can be set. In addition, the SLEEP mode can be activated.

Automatic

In the automatic operating mode, the air conditioner automatically switches between the ventilation and cooling operating modes to maintain a temperature of 24 °C.

  • At a room temperature ≥ 24 °C, the air conditioner switches to cooling mode.
  • At a room temperature < 24 °C, the air conditioner switches to ventilation mode.

Switching the air conditioner on and off

  1. Press the ON/OFF button (k) to switch on the air conditioner. The status display (c) shows the room temperature and the air conditioner is in automatic mode.
  2.  Press the ON/OFF button (k) again to switch off the air conditioner.

Selecting an operating mode

  • Press the MODE button (r) to change the operating mode. The operating modes are cycled through in this order:

Setting the temperature

the temperature(set temperature) can be set in a range from 15 °C to 31 °C in steps of 1 °C. The air conditioner does not have a heating function. If the set temperature is higher than the room temperature, the air conditioner will not work. The temperature can only be set in cooling mode.

  1. Press the UP button (p) to increase the value by 1 °C.
  2.  Press the DOWN button (o) to decrease the value by 1 °C. The set temperature flashes in the status display (c). After 5 seconds, the status display shows the current room temperature again.

Setting the fan speed

Two fan speeds are available: light fan and a strong fan.

  •  Press the SPEED button to change the fan speed. The fan speeds are cycled through in this order:

Setting the timer function

The air conditioner has a timer function. The timer function can be set at intervals from one hour to 24 hours.

  1. Press the TIMER button (n) to activate the timer function. The value for the timer flashes in the status display (c). The TIMER status indicator flashes yellow.
  2. Press the UP button (p) to increase the value by 1 hour.
  3. Press the DOWN button (o) to decrease the value by 1 hour.
  4. When you have set the desired duration for the timer, wait about 5 seconds. The status display switches to the current room temperature and the set timer is active. The TIMER status indicator lights up yellow.
  5. Press the TIMER button (n) again to deactivate the timer function.

Activating and deactivating the child lock

The air conditioner has a child lock. When the child lock is active, the function of all buttons on the control panel and the remote control is locked.

  1. Press the LOCK button (s) for about 5 seconds to activate the child lock. A signal tone sounds. The LOCK status indicator (1) lights up green.
  2. Press the LOCK button (s) again for about 5 seconds to deactivate the child lock.

Maintenance and care

DANGER:  Risk of electric shock

  • Always disconnect the mains plug before cleaning.
  • Do not use the product with wet hands.
  • Make sure that no water or moisture gets inside the unit!
  • Never insert a wet or damp air filter into the air conditioner!
  • Do not expose the product to direct water jets.

NOTICE:  Material damage

  • Make sure that no water comes into contact with electrical components!
  • Only use a dry and soft cloth for cleaning.
  •  In case of heavy soiling, the cleaning cloth can be slightly moistened with water.
  • Do not use detergents or chemicals.
  •  Be careful when cleaning to avoid scratches.

maintenance intervals

Maintenance task| before each
use| if necessary| at least every
2 weeks| at least
annually
---|---|---|---|---
Checking air inlets and outlets for dirt and clean if necessary.| x| x| |
Cleaning the housing| | x| | x
Visual inspection of the inside of the unit for dirt| | x
x| |
Cleaning the air filter| | x| x|
Examining the air conditioner for damage
x| | | |
Emptying the condensate container| | x| |

Visual inspection of the inside of the unit for dirt

Look into all openings of the air conditioner. If necessary, use a torch to improve visibility. You can also remove the air filter (7) to better see the inside of the unit. If you see a thick layer of dust, have the air conditioner professionally cleaned by a specialist refrigeration and air conditioning company.

Cleaning the air filter

The air filter (7) must be cleaned regularly. Otherwise, malfunctions or reduced performance of the unit may occur. How often the air filter must be cleaned depends on the ambient conditions. If the air conditioner is used regularly, you need to clean the air filter approximately every 2 weeks or after about 100 hours of operation. In particularly dusty environments, the air filter should be cleaned more often. Follow these steps to clean the air filter:

  1. Switch off the air conditioner and unplug the main cable from the socket at the plug.

  2. Grasp the handle on the right side of the air filter.

  3.  Pull the air filter towards you until it comes off.

  4. Clean the air filter with a dry, soft cloth or vacuum it carefully with a hoover.
    If the air filter is very dirty, you can also use lukewarm water and a gentle detergent to clean it.
    Allow the air filter to dry completely.
    Never insert a damp or wet air filter into the air conditioner!

  5.  Make sure that the air filter is neither worn nor damaged.

  6.  Reinstall the air filter.
    You may have to press a little harder until you hear it click into place.

Emptying the condensate container

WARNING: Risk of poisoning

The condensate is not of drinking water quality and can cause poisoning if consumed.

  • Do not drink the condensate!
    NOTICE!  Material damage!
    Water flowing out of the air conditioner can damage floors and furniture.

  • Empty the condensate container in a suitable place (e.g. over a drain).

  • Make sure that the outlets for condensate are properly closed.
    Condensate is produced in the operating modes of cooling and dehumidification. A large part of the condensate is discharged to the outside via the exhaust air.
    The remaining condensate collects in a container inside the unit. If the error code „E4“ appears in the status display (c), the condensate container must be emptied.

Proceed as follows to empty the condensate container:

  1.  Switch off the air conditioner and disconnect the main cable from the socket at the plug.

  2.  Transport the air conditioner to a suitable place and take a collection container. The collection container should be able to hold approx. 1.1 l.

  3.  Hold the collection container under the upper condensate outlet (8).

  4.  Open the upper condensate outlet and allow the condensate to drain into the collection container.

  5.  Close the upper condensate outlet with the plug.

  6. Empty the collection container.

  7. Hold the collection container under the lower condensate outlet (10).
    Alternatively, you can position the air conditioner above a floor drain.

  8.  Open the lower condensate outlet and allow the condensate to drain into the collection container or into a floor drain.

  9.  Close the lower condensate outlet with the plug. The condensate container is now empty. The error code in the status display is no longer shown.

Storage

DANGER: Fire hazard!

The air conditioner contains propane (R290) as a refrigerant. Propane in combination with air is highly combustible and can lead to an explosion.

  •  Only operate and store the air conditioner in rooms with an area of 10 m² to avoid the danger of a concentration of flammable gas building up in the air.
  • Do not operate the air conditioner in rooms where there are sources of ignition (e.g. naked flames, electric heaters, gas appliances that are switched on).

CAUTION: Irritation of the respiratory tract
Moisture in the air conditioner can lead to deposits and mold.

If you do not use the air conditioner for the next seven days, store it according to the following instructions. Perform the following operations before storing the air conditioner

  1.  Empty the condensation tank (see chapter 12.4).
  2.  Clean the air filter (see chapter 12.3).
  3.  Leave the air conditioner running in ventilation mode for 5 to 6 hours in a dry room to allow the inside of the air conditioner to dry.
  4. Remove the batteries from the remote control.
  5.  Store the air conditioner in a suitable place. In particular, observe the instructions in the section „Operation and storage conditions“ in chapter 1.

Faults and malfunctions

Safety device

The air conditioner is equipped with a safety device designed to protect the compressor. In case of frequent switching on and off or sudden disconnection from the mains, delays of up to 3 minutes may occur. This function is intentional and does not represent a malfunction. The safety device also becomes active if the air conditioner is used outside the permissible operating temperature (see chapter 2.4).

Troubleshooting

In the following, some errors are listed that you can fix yourself. If you cannot find the error in the following table or if the suggested solutions do not work, contact the dealer or manufacturer or contact an authorized specialist company for refrigeration and air-conditioning technology.

Error Cause Solution
The air conditioner cannot be switched on. The safety device has been
triggered. → Wait 3 minutes and then try to switch on the air conditioner

again.
The mains plug is not plugged in.| →Plug the mains plug into a wall socket.
The batteries of the remote control are empty.| →Insert new batteries into the remote control.
The built-in fuse has blown.| →Contact the dealer or manufacturer or contact an authorized specialist.
The air conditioner operates only for a short time.| The set temperature is higher than or equal to the room temperature.| → Set a lower temperature.
The air outlet is blocked.| → Remove the blockage from the air outlet.
The air conditioner operates in cooling mode, but the room temperature does not drop.| Warm air from outside is co- ming in through an open door or window.| → Close the door or window. If the exhaust hose is routed through the door or window, it must remain open.
Another appliance in the room is generating waste heat.| → Switch off the heat-generating appliance.
The air filter is dirty.| → Clean the air filter.
The air inlet or outlet is blocked.| → Remove the blockage.
The set temperature is higher than the room temperature.| →. Set a lower temperature.
The air conditioner starts to freeze and goes into defrost mode.| → Wait for the defrosting process. Then you can continue to use the air conditioner as usual.
The exhaust air hose is not routed correctly or is blocked.| →Follow the instructions in chapter 7.2.
The room is larger than 20 m2.| →.Use the air conditioner in rooms with a maximum size of 20 m2.
Water is dripping from the air conditioner.| The air conditioner has been moved without emptying the condensate container.| →Empty the condensate container before moving the air conditioner.
The air conditioner is placed on an uneven surface.| → Move the air conditioner to a more suitable location (see chapter 7.1).
The upper or lower condensate outlet is not properly closed.| →Close the outlet with the plug.
The air conditioner suddenly switches off or stops working.| The set timer has expired.| → Switch the air conditioner on again.
---|---|---
The set temperature has been reached.| → Set a lower temperature or wait for the next cooling cycle.
The condensate container is full and the error code “E4” appears in the status display.| → Empty the condensate container (see chapter 12.4).
The air conditioner makes unusual noises or vibrates strongly.| The air conditioner is installed in an unsuitable location.| → Move the air conditioner to a more suitable location (see chapter 7.1).
The air conditioner. makes bubbling noises.| Refrigerant is flowing through the cooling circuit.| → This does not represent a malfunction but is a normal operating noise.
The air conditioner has an unpleasant smell.| Deposits or mold have formed in the air conditioner.| → Have the air conditioner professionally cleaned by an authorized specialist company for refrigeration and air conditioning.

14.3 Error codes
The following error codes may appear in the status display (c):

Error cod Cause Solution
E4 The condensate container is full.  → Empty the condensate container (see

chapter 12.4).
If this error code occurs very frequently, contact the dealer or manufacturer or contact an authorized specialist company for refrigeration and air conditioning.
E2| The sensor for determining the room temperature is disturbed or defective.|  → Contact the dealer or manufacturer or contact an authorized specialist company for refrigerati- on and air-conditioning technology.
E3| The sensor for monitoring the evaporator is disturbed or defective.
E5| The sensor for monitoring the
compressor is disturbed or defective.

Disposal instructions

Product

According to the European WEEE directive, electrical and electronic equipment must not be disposed of with consumers’ waste. Its components must be recycled or disposed of apart from each other. Otherwise contaminative and hazardous substances can damage health and pollute the environment.
As a consumer, you are committed by law to dispose of electrical and electronic devices to the producer, the dealer, or public collecting points at the end of the device’s lifetime for free. Particulars are regulated in national rights. The symbol on the product, in the user manual, or at the packaging alludes to these terms. With this kind of waste separation, application, and waste disposal of used devices you achieve an important share to environmental protection.

WEEE No: 82898622

Batteries

(Rechargeable) batteries must not be disposed of with household waste. Their components have to be supplied separately to recycling or disposal because toxic and dangerous ingredients can harm the environment if not disposed of sustainably. As a consumer, you are obliged to return them at the end of their service lives to the manufacturer, the sales outlet, or established for this purpose, public collection points for free. Details regulate the respective country‘s law.The symbol on the product, the instruction manual, and/or the packaging draws attention to those provisions. With this kind of material separation, recovery, and disposal of waste (rechargeable) batteries you make an important contribution to protecting our environment.

Packaging
Packaging can be disposed of free of charge at suitable collection points – paper belongs in
paper bins, plastics belong in yellow sacks and glass belongs in used glass bins.
DE4535302615620

EU Declaration of Conformity

****With the CE sign, Goobay®, a registered trademark of Wentronic GmbH, ensures that the product is conformed to the basic European standards and directives.

Symbols used

The following safety signs and symbols are used on the appliance and in the operating instructions.

Warning; Flammable material ISO 7010 – W021 ****

To indicate that the operating instructions should be considered when operating the device| ISO 7000 – 1641|
To indicate that the operator’s manual or card should be read before continuing the operation| ISO 7000 – 0790|
To indicate that the technical manual shall be consulted| ISO 7000 – 1659|
The „GS” test symbol stands for „Tested Safety”. Ready-to-use products and work equipment are marked with the GS mark to comply with the requirements of the German Product Safety Act (ProdSG).| _|
Alternating current| IEC 60417- 5032|
Direct current| IEC 60417- 5031|

Recycling| ISO 7001 – PI PF 066|
Protective earth; protective ground (Class I equipment)| IEC 60417- 5019|

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals