IMPORTANT SAFETY INSTRUCTION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/ abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
WARNING
RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
- Do not exceed maximum wattage marked on luminaire label.
- Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION
RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF FIRE
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
- Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
- Only use fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
- Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
Please see product specific installation instructions for additional warnings
or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For
a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
Our Brands
- Indoor/Outdoor
- Lithonia Lighting
- Carandini
- Holophane
- RELOC
- Light Concepts
- Indoor Lighting
- Gotham
- Mark Architectural
- Lighting Peerless
- Renaissance Lighting
- Winona Lighting
- Outdoor Lighting
- American Electric Lighting
- Antique Street Lamps
- Hydrel
- Tersen
- Controls
- DARK TO LIGHT
- LC&D
- ROAM
- Sensor Switch
- Synergy
- Daylighting
- Synergy
Installation Instructions
SECTION A
-
CAUTION: APPLY A CONTINUOUS BEAD OF WEATHER–PROOF CAULKING BETWEEN MOUNTING BASE PLATE AND WALL TO ENSURE WEATHER–TIGHT INTEGRITY OF ELECTRICAL COMPONENTS.
-
Secure base plate to wall with (4) 1/4” diameter fasteners (by others) using the (4) holes located on the outer corners of the base plate oriented as shown with the embossed part number on the top.
Check the base plate to confirm that it is level and plumb in all directions. -
Prepare the cover plate by verifying the factory installed gasket is in place on the backside of the cover plate.
-
Note for the next steps the curved portion of the cover plate should point upwards when mounted to the wall.
Note: The next pages are luminaire specific.
Choose the SECTION B installation steps corresponding to the luminaire being
installed (also reference the luminaire installation instruction sheet).
SECTION B-RAD1
- Make certain that all power is disconnected prior to installing the fixture.
- For wall mounting, slide the square pole adaptor onto the threaded rod first. Insert threaded rod of luminaire arm into top hole of WBA cover plate and through the unthreaded top hole of backing plate. Align the center unthreaded hole of the backing plate with the WBA cover plate’s center hole. See Figure 1B.
- Using 9/16” wrench tighten nut onto threaded rod to 20-25 ft-lb.
- Using T20 driver, loosen single screw holding wiring access cover and set aside for reinstallation. See Figure 2B.
- Using the supplied 3/8” bolt, slide it into the arm, through the bottom hole on the square pole adaptor, cover plate and into lower threaded hole of backing plate. Using 9/16” wrench to 20-25 ft-lb. See Figure 3B.
- Pull wires through the center hole of the arm, square pole adaptor, cover plate, and backing plate.
- By aligning hooks within the cutouts in the front of the arm, replace the wire access cover (from step 4) and tighten the screw using T20 driver to 15-20 in-lb. See Figure 4B.
- Proceed to section C.
SECTION B-RSX/VCPG/KAX
- Open up the luminaire carton and locate the threaded steel bar, and the 2″ long, 3/8” diameter lock bolts (2). Stop Important: Installing a RSX, KAX or VCPG series luminaire, you will discard the 1-1/2” long bolts that came with the wall mounting assembly and use the 2” long luminaire bolts.
- On the underneath side of the luminaire arm, remove the wire access cover plate and set aside for reinstallation. (Figure 1B)
- Insert the 3/8” lock bolts through the back wall of the luminaire arm, through the cover plate, and then thread into the threaded steel bar, simultaneously pulling the wires through the center hole (Figure 2B). The luminaire is supplied with a clearance slot in the back to allow wires to be pulled into the WBA cover plate. Tighten the two bolts with a 9/16” hex socket to 20-30 ft-lbs.
- Make sure that wires are not pinched and tuck excess wire up into the luminaire mounting area. Reinstall the wire access cover plate from step 2, and tighten the two captive screws with the 9/64 Allen wrench to 18-20 in-lbs.
- Proceed to section C.
SECTION B- AS2, AST2, MR2, MRT2, CSX, DSX G1
- Prepare the cover plate by attaching the Aeris mounting block to the cover plate using (2) 3/8″ diameter by 1-1/4″ bolts with lockwashers by inserting the bolts and washers into the mounting block through the cover plate and thread into the threaded steel bar stock. Use a 9/16″ socket or wrench and tighten securely (Figure 1B).
- Open doorframe by loosening the (2) captive doorframe screws using 3/16″ allen wrench.
- Unhook safety-restraining cable. Loosen the 10-24 screw at the neck end of the doorframe 1/2 turn.
- Remove door by sliding the hinge latch up and away from hinge, close door slightly and lift door assembly off. Set aside for reinstallation.
- Pull the wires from the luminaire through the mounting block on the cover plate and through the center hole of the threaded steel bar. Place luminaire onto the mounting block, being sure the wires are not being pinched. Tighten the locking hex head bolt inside the arm with a 9/16″ socket to 20-30 ft. lbs. torque.
- Re-install the door assembly by placing hinge of doorframe on fixed hinge rod of luminaire. Slide hinge latch on the doorframe over hinge rod. Tighten 10-24 hinge latch screw. Reinstall safety-restraining cable (from step 3).
- Proceed to section C
SECTION B- AS1, AST1, MR1, MRT1
- Prepare the cover plate by attaching the Aeris mounting block to the cover plate using (2) 3/8″ diameter by 1-1/4″ bolts with lockwashers by inserting the bolts and washers into the mounting block through the cover plate and thread into the threaded steel bar stock. Use a 9/16″ socket or wrench and tighten securely (Figure 1B).
- Open doorframe by loosening the (2) captive doorframe screws using 3/16″ allen wrench.
- Unhook safety-restraining cable. Loosen the 10-24 screw at the neck end of the doorframe 1/2 turn.
- Remove door by sliding the hinge latch up and away from hinge, close door slightly and lift door assembly off. Set aside for reinstallation.
- Pull the wires from the luminaire through the mounting block on the cover plate and through the center hole of the threaded steel bar. Place luminaire onto the mounting block, being sure the wires are not being pinched. Tighten the locking hex head bolt inside the arm with a 9/16″ socket to 20-30 ft. lbs. torque.
- Re-install the door assembly by placing hinge of doorframe on fixed hinge rod of luminaire. Slide hinge latch on the doorframe over hinge rod. Tighten 10-24 hinge latch screw. Reinstall safety-restraining cable (from step 3).
- Proceed to section C.
SECTION B-KAD
- Pre-assemble the cover plate, mounting bar, threaded rods, gaskets and mounting arm together. (Figure 1B)
- Open the door of the luminaire and insert the pre-assemble components through the back wall of the luminaire housing, with thread rods into the luminaire housing, pulling the wires all the way through the center hole in the threaded steel bar.
- Tighten the two acorn nuts and lockwashers with a 9/16” hex socket to 20-30 ft-lbs (overtightening can damage components and void warranties).
- Close the door of the luminaire and tighten closing screws.
- Proceed to section C.
SECTION C
CAUTION THE NEXT STEPS WILL REQUIRE ASSISTANCE
- Make all wiring connections via the supplied wire leads in accordance with NEC and local codes.
- Place the entire luminaire/cover plate assembly onto the base plate and have someone tighten the top (2) 3/8” x 1-1/4” stainless steel recessed hex set screws until 3/8” to 1/4” of the screw threads are still visible. (Figure 1C)
- Now tighten the bottom (2) 3/8” x 1-1/4” stainless steel recessed hex set screws until 3/8” to 1/4” of the screw threads are still visible.
- Now alternating between the top two and bottom two set screws, gently tighten until snug (approximately one thread will remain showing on each screw).
Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012
Phone: 1-800-705-7378
www.lithonia.com
© 2011 Acuity Brands Lighting, Inc. All rights reserved. Rev 5/14