Product Information

  • Product Name: Decken- und Wandleuchte (Ceiling and wall luminaire)
  • Model Number: 24 027
  • IP Rating: IP 65

The Decken- und Wandleuchte is an unshielded ceiling and wall luminaire with a high protection class (IP 65). It is suitable for a variety of interior and exterior lighting applications.

Product Usage Instructions

  1. Safety:

The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should perform the installation and commissioning. The manufacturer is not liable for any damage caused by improper use or installation. If any modifications are made to the luminaire, the person responsible for these modifications will be considered the manufacturer.

  1. Overvoltage Protection:

The electronic components in the luminaire are protected against overvoltage in accordance with DIN EN 61547. For additional protection against transients, it is recommended to use separateovervoltage protection components. These components can be found on the manufacturer’s website at www.bega.com.

  1. Lamp Specifications:

The luminaire is compatible with the following lamp modules:

  • Module K3:
    • Module Designation: LED-0832/830
    • Colour Temperature: 3000 K
    • Colour Rendering Index (CRI): > 80
    • Module Luminous Flux: 4935 lm
    • Luminaire Luminous Flux: 3317 lm
    • Luminaire Luminous Efficiency: 107.7 lm/W
  • Module K4:
    • Module Designation: LED-0832/840
    • Colour Temperature: 4000 K
    • Colour Rendering Index (CRI): > 80
    • Module Luminous Flux: 5010 lm
    • Luminaire Luminous Flux: 3367 lm
    • Luminaire Luminous Efficiency: 109.3 lm/W
  • Installation:

During installation or relamping, avoid touching the light output opening of the LED directly.

Follow these steps for installation:

  1. Lead the mains supply cable through the cable entry of the luminaire base.
  2. Fix the luminaire base onto the mounting surface using the enclosed or any other suitable fixing material.
  3. Make the earth conductor connection and the electrical connection.
  4. If using digital control, use the connecting terminal DA, DA. If this terminal is not used, the luminaire will operate at full light output.
  5. To ensure maximum service life of the electrical components, place the enclosed desiccant pouch in the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label before closing the luminaire.

Instructions for use

Application Lichtbausteinb Circle
Unshielded ceiling and wall luminaire with high protection class for a variety of interior and exterior lighting applications.

Product description

  • Luminaire made of aluminium alloy and stainless steel
  • BEGA Unidure® coating technology
  • Opal glass satin matt
  • Silicone gasket
  • 2 mounting holes ø 5.5 mm
  • Distance apart 283 mm
  • 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@ Connecting terminal 2.5@  with plug connection
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK05
  • Protection against mechanical
  • impacts < 0.7 joule
  • – Safety mark
  • – Conformity mark
  • Weight: 3.8 kg
  • This product contains light sources of energy efficiency classes CBEGA-24-027-Ceiling-And-Wall-Luminaire-fig-1

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp
Module-connected wattage: 27.6 W
Luminaire connected wattage: 30.8 W
Rated temperature: ta = 25 °C
Ambient temperature: ta max = 45 °C

24 027 K3
Module designation: LED-0832/830
Colour temperature: 3000 K
Colour rendering index: CRI > 80
Module luminous flux: CRI > 80
Luminaire luminous flux : 3317 lm
Luminaire luminous efficiency: 107,7 lm / W

24 027 K4
Module designation: LED-0832/840
Colour temperature: 4000 K
Colour rendering index : CRI > 80
Module luminous flux: 5010 lm
Luminaire luminous flux :3367 lm
Luminaire luminous efficiency: 109,3 lm / W

Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Lead the mains supply cable through the cable entry of the luminaire base.Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface. Make the earth conductor connection and the electrical connection. For digital control please use the connecting terminal DA, DA. In case this terminal is not used the luminaire will be operated at full light output. In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire. Push plug into coupler as far as it will go. Make sure that gasket is positioned correctly. Place the opal glass with LED unit onto the luminaire base in such a way that both yellow arrow markers align to each other and screw the glass clockwise into the base up to the stop.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. Inspect and, if necessary, replace the luminaire gaskets. Defective glass must be replaced. Close the luminaire.

Spares

  • LED power supply unit: DEV-0270/700i
  • LED module 3000 K: LED-0832/830
  • LED module 4000 K: LED-0832/840
  • Spare glass: 75 004 035
  • Gasket: 83 001 636

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com