Berker KNX-RF Switch Actuator Surface Instructions

June 4, 2024
Berker

Berker KNX-RF Switch Actuator Surface

Operation instructions

Caution

  • This device must be installed only by a qualified electrician according to the installation standards in force in the country.

The devices are waterproof radio receivers, switching respectively 1 or 2 electric loads in ON/OFF mode. The devices can be controlled remotely via radio transmitters (e.g. flush-mounted devices, radio push-buttons, hand-held transmitters).

Caption

  1. Button and R configuration LED
  2. 3 Button and LED feature T of outputs S1 and S2 (1gang version: S1)
  3. Connector block.

Features

  • Forced mode operation available
    • 1 or 2 independent channels are controlled by a KNX radio.
    • 1 or 2 volt-free contacts μ 10A, 230 Vv AC-1 Operation :
    • Availability of outputs manual control by function buttons 2 and 3.
    • Display of outputs’ states on LEDs 2 and 3 (red light ON = closed relay). The specific features of each product depend on configuration and set-up.

Configuration
The devices may be configured in 3 different ways :

  •  quick links : configuration without tool, directly on the device via buttons R and T
    (see configuration instructions quick links)

  • this TX: configuration using connection device from Hager

  •  ETS3/ETS4 via KNX-RF/TP gateway: database and description of software application available from the Manufacturer.

The Product configuration factory reset mode. is required to change

Repeater feature
It increases the system radio range thanks to the re-transmission of messages received by the product. It is inactive by default and can be enabled/ disabled by pressing once > 2 s R button on product power-on. cfg LED flashing on power-on signals that the repeater feature is active.

Factory Reset
Maintain R button down until LED cfg flickers 10 s, then release. cfg LED turns OFF to signal reset to factory settings end. This operation removes the entire product configuration in any configuration mode.  After power switch-on or reset to factory settings, wait for 15 s before to do a new configuration.

Correct Disposal of This product (Waste Electrical & Electronic Equipment).

(Applicable in the European Union and other European countries with separate collection systems). This marking shown on the product or its literature indicates that it should not be disposed of with other household wasted at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please sepa-rate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local go-vernment office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes of disposal.

Berker-KNX-RF-Switch-Actuator-Surface-fig-2

Load types

Technical characteristics