85105100 Berker Net Instruction Manual

June 12, 2024
Berker

85105100 Berker Net

85105100-Berker-Net-PRO

Product Information

  • Product Name: 6LE003070C
  • Manufacturer: Berker GmbH & Co. KG
  • Order Number: 8510 51 00
  • Website: www.berker.com
  • Address: Zum Gunterstal 66440 Blieskastel/Germany
  • Phone: +49 6842 945 0
  • Fax: +49 6842 945 4625
  • Email: [email protected]
  • Date: 09/2022

The device is a radio receiver switching the load connected to the socket in a ON/OFF mode. The device can be controlled remotely via radio transmitters (e.g. flush-mounted devices, radio push-buttons, hand-held transmitters).

Caption

85105100-Berker-Net-4

  1. Button and configuration LED.
  2. Button and LED feature of output.

Operation

  • Availability of manual control using button
  • Display of output state on LED fct (red light ON = relay closed).
  • The specific features of each product depend on configuration and set-up.

Mains break
After mains break, the socket will always remain in Off state.

Configuration

The device may be configured in 3 different ways:

  • quicklink : Configuration without tool, directly on the device via buttons and (see configuration instructions quick links )
  • tebis TX: Configuration using connection device from Hager
  • ETS3/ETS4 via KNX-RF/TP gateway: Database and description of software application available from the Manufacturer.

In order to change the configuration mode, a reset to factory settings is required.

Repeater feature

It increases the system radio range thanks to the re-transmission of messages received by the product. This function is inactive by default and can be enabled/disabled by pressing once > 2 s button on product power-on. cfg LED flashing on power-on signals that the repeater feature is active.

Reset to factory settings85105100-Berker-Net-5
Maintain button down until LED cfg flickers > 10 s, then release. cfg LED turns OFF to signal reset to factory settings end. This operation removes the entire product configuration in any configuration mode. After power switch-on or reset to factory settings, wait for 15 s before to do a new configuration.

Correct Disposal of This product

(Waste Electrical & Electronic Equipment).
(Applicable in the European Union and other European countries with separate collection systems).
This marking shown on the product or its literature indicates that it hould not be disposed with other household wasted at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes of disposal

Hereby, hager Controls, declares that this nested radio socket is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/UE. The CE declaration can be consulted on the site : www.hager.com

Load types

85105100-Berker-Net-6

Technical characteristics

85105100-Berker-Net-7

Berker GmbH & Co. KG – Zum Gunterstal – 66440 Blieskastel/Germany –
Tel.: +49 6842 945 0
Fax: +49 6842 945 4625
E-Mail: [email protected]
www.berker.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Berker User Manuals

Related Manuals