Safety instructions
Electrical equipment must only be installed and assembled by a qualified
electrician in accordance with the relevant installation standards,
directives, determinations and safety and accident prevention directives of
the country.
Failure to comply with these instructions may result in damage to the device,
fire or other hazards.
Hazard due to electric shock. Disconnect before working on the device. Take
into account all circuit breakers that feed dangerous voltages to the device.
Hazard due to electric shock. The device is not suited for safe disconnection
of the mains supply.
Hazard due to electric shock. Do not operate device without the application
module.
If several drives should be connected in parallel to one output, it is
mandatory to observe the manufacturer‘s data; use a cut-off relay where
required. Drives can be destroyed.
Use blind drives with mechanical or electrical final position switches only.
Check final position switches for correct adjustment. Observe manufacturer‘s
data. The device can be damaged.
Use blind push-buttons only for extension unit operation. The use of blind
push-buttons can cause malfunctions.
Hazard of injury. Use the device to control blind, shutter or awning drives
only. Do not switch any other loads.
Observe the motor manufacturer‘s data regarding change-over time and max.
switch-on time (ED).
Do not lay control lines in parallel to the motor lines (danger of coupling).
These instructions are an integral component of the product, and must be
retained by the end user.
Design of the device
- Shutter insert
- Frame
- Application module e.g. from a push-button for blinds
- Screw for dismantling protection (not R.1/R.3)
- Blind button design cover
- Connecting terminals
Function
Correct use
- Switching electrically operated blinds, shutters, awnings and similar hangings.
- Circuiting of extension units push-buttons for blinds, blind inserts, key push-buttons for blind possible
- Only suitable for use in indoor areas, no drip or spray water.
- Installation in wall box according to DIN 49073.
- Operate with suitable application module (see „Accessories“)
Product characteristics
- 2 mechanically and electrically mutually locked relay contacts.
Operation
These instructions describe the installation of the shutter insert. The
operation and function of the application modules are described in the
instructions of the respective cover.
The function of the extension unit is only possible when there is an
application module attached to the master unit.
Information for electricians
Assembly and electrical circuiting
Danger!
Touching live parts can result in an electric shock.
An electric shock can be lethal.
Disconnect the connecting cables before working on the device and cover all
live parts in the area!
Circuiting and mounting of shutter insert
A MCB max. 10 A is installed as device protection.
- Circuit shutter insert according to circuiting diagram (Figure 2).
- Install shutter insert in wall box (recommended: deep box). The connection terminals must be at the bottom.
- Attach the frame and application module (see instructions for application module).
Individual control with push-button for shutter extension unit
- Individual control with push-button for blind extension unit according to circuiting diagram.
Individual control with key push-button for shutter extension unit
- Connect individual control with key push-button for shutter extension unit according to circuiting diagram.
Control by sensors
Sensors such as wind/precipitation sensors are used e.g. to protect awnings
from damage. If a threshold is exceeded on the sensors, blinds/awnings etc are
retracted.
When using sensors, the operating mode might have to be changed to protection
mode (see Cover instructions).
(7) Sensor (e.g. wind/precipitation)
- Connect sensor (7) according to connection diagram (Figure X).
Master and group control
-
Circuit master and group control according to circuiting diagram (figure 5).
Master control under application of various RCCBs -
Circuit master control under application of various RCCBs according to circuiting diagram (figure 6).
Appendix
Technical data
Rated voltage | AC 230 V, + 10 % /- 15 % |
---|---|
Mains frequency | 50/60 Hz |
MCB | max. 10 A |
Switching current (cos φ 0.6) | 3:00 AM |
Change-over time to the opposite running direction | 0.6 sec. |
Standby power consumption | < 0.1 W |
Relative humidity | 0 … 65 % (no condensation) |
Ambient temperature | -5°C … +45°C |
Storage/transport temperature | -20°C … +60°C |
Extension unit cable length | max. 50 m |
Load cable length | max. 100 m |
Number of extension units | unlimited |
Connecting terminal | 1 x 2.5 mm² or 2 x 1.5 mm² |
Mounting orientation | connecting terminals downwards |
Housing installation depth | 22 mm |
Claw guidance installation depth | 32 mm |
Accessories
Push-button for blinds | 8524 11 xx |
---|---|
Blind time switch | 8574 11 xx |
Radio push-button for blinds quicklink | 8524 51 xx |
Radio blind time switch quicklink | 8574 51 xx |
Warranty
We reserve the right to make technical and formal changes to the product in
the interest of technical progress.
Our products are under guarantee within the scope of the statutory provisions.
If you have a warranty claim, please contact the point of sale or ship the
device postage free with a description of the fault to the appropriate
regional representative.
Berker GmbH & Co. KG
Zum Gunterstal
66440 Blieskastel/Germany
Tel.: + 49 6842 945 0
Fax: + 49 6842 945 4625
E-Mail: info@berker.de
www.berker.com
04/2021
6LE003246B
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>