ARCORA AR6101800B 4 Inch Centerset Double Handle Bathroom Faucet Instruction Manual

June 12, 2024
ARCORA

ARCORA AR6101800B 4 Inch Centerset Double Handle Bathroom Faucet

Product Information

The Two Handle Lavatory Centerset Faucet is a durable and efficient faucet designed for easy installation. It has a 1.2GPM (4.5L/min) water flow rate, which complies with California water efficiency regulations. The faucet is also compliant with California Proposition 65 and the Federal Safe Drinking Water Act. Its finish is extremely durable, but it should be cleaned with care to avoid damage from harsh abrasives or polish.

Product Usage Instructions

Before beginning the installation, it is important to read all the instructions, warnings, care, and maintenance information provided in the manual.

Cleaning and Care
To clean the faucet, simply wipe it gently with a damp cloth and blot dry with a soft towel. Avoid using harsh abrasives or polish that may damage the finish.

Maintenance

If the faucet exhibits very low flow, follow these steps:

  1. Remove and clean the aerator with your hand.
  2. Shut off the water supply valves.
  3. Replace the valve assembly.
  4. When reinstalling parts, make sure the bonnet nut is tightened securely with a wrench.

If the faucet leaks from under the handle, use a wrench to ensure the bonnet nut is tight. If the leak persists, shut off the water supply valves and replace the valve assembly. When reinstalling parts, make sure the bonnet nut is tightened securely with a wrench. If the faucet leaks from the spout outlet, shut off the water supply valves and replace the valve assembly. When reinstalling parts, make sure the bonnet nut is tightened securely with a wrench. Install the valve assembly correctly for proper handle rotation.

Installation:

Before installing the valves, clean the water pipe thoroughly to avoid dirt and deposits. Use silicone under the base if the deck is uneven.

  1. Attach the mounting nut to the hot and cold threaded mounting shanks and tighten the faucet to the basin.
  2. Attach the supply lines, making sure not to overtighten.
  3. Turn the water back on.

To connect the drain assembly:

  1. Remove the washer, black gasket, and nut from the assembly.
  2. Slide the washer up to the underside of the flange. Insert the flange and washer into the sink and secure with the black gasket, washer, and nut from underneath the sink.
  3. Put down and check the spring-loaded stopper.
  4. Connect the assembly to the drain.

To flush debris from the plumbing system:

  1. Remove the aerator by hand.
  2. Run hot and cold water for one minute.
  3. Replace the aerator.

Repeat the above steps for the other hose connection, ensuring that the hose with the hot label is connected to the hot supply valve and the other hose is connected to the cold supply valve. After connecting all hoses, turn on the hot and cold water supplies and flush water lines for one minute. Check all connections for leaks at arrows. Retighten if necessary, but do not overtighten.

TWO HANDLE LAVATORY CENTERSET FAUCETS

ARCORA-AR6101800B-4-Inch-Centerset-Double-Handle-Bathroom-Faucet-
fig-1

For easy installation of your faucet you will need:

  • To READ ALL the instructions completely before beginning.
  • To READ ALL warnings, care, and maintenance information.

Cleaning and Care

  • Care should be given to the cleaning of this product. Although its finish is extremely durable,
  • It can be damaged by harsh abrasives or polish. To clean, simply wipe gently with a damp cloth and blot dry with a soft towel.

With 1.2 gpm are compliant with California water effi ciency regulations, Complies with California Proposition 65 and with the Federal Safe Drinking Water Act.
In areas with extremely low water pressure causing the basin faucet water flow to be unsatisfactory , replace the 2.2 gpm aerator to improve the water flow in the basin faucet.

Maintenance

If faucet exhibits very low flow:

  • A. Remove and clean aerator (2) with hand,
  • B. Shut off water supply valves.
    Replace valve assembly (4).
    When reinstalling parts, make sure bonnet nut (5) is tightened securely with a wrench.

If faucet leaks from under handle:
Using a wrench, ensure bonnet nut

  • (5) is tight.
  • If leak persists:
  • Shut off water supply valves.Replace valve assembly (4). When reinstalling parts, make sure bonnet nut (5)is tightened securely with a wrench.

If faucet leaks from spout outlet:

  • Shut off water supply valves.
  • Replace valve assembly (4).
  • When reinstalling parts, make sure bonnet nut (5) is tightened securely with a wrench.
  • Install valve assembly (4) correctly for proper handle rotation.

ARCORA-AR6101800B-4-Inch-Centerset-Double-Handle-Bathroom-Faucet-
fig-3

OPERATION

  • Double levers style handles
  • Maximum handle(s) rotation angle is 90˚ to full on
  • Rotate hot side counter clockwise to open (clockwise to close)
  • Rotate cold side clockwise to open (counter clockwise to close)

Notes
Before installing the valves, clean the water pipe thoroughly to avoid dirt and deposits.

Instructions

  • Provided with necessary models.
    OPTION : Use silicone under the base if deck is uneven.ARCORA-
AR6101800B-4-Inch-Centerset-Double-Handle-Bathroom-Faucet-
fig-6

  • Attach the mounting nut to the hot and cold threaded mounting shanks and tighten faucet to basin.

  • Attach supply lines . Do not overtighten. Turn water back on.

  1. Remove the washer (2) , black gasket (4) and nut (5) from the assembly.

  2. Slide washer (2) up to underside of flange (3).
    Insert flange (3) and washer (2) into sink and secure with the black gasket (4) washer and nut (5) from underneath the sink.

  3. Put down and check the Spring loaded stopper (1).

  4. Connect assembly to drain.

To flush debris from the plumbing system:

  1. Remove the aerator by hand.
  2. Run hot and cold water for one minute.
  3. Replace the aerator.
  • Repeat for other hose connection making sure the hose with the hot label is connected to the hot supply valve and the other hose is connected to the cold supply valve.
  • FLUSH SYSTEM/CHECK FOR LEAKS. Turn on hot and cold water supplies and flush water lines for one minute. Check all connections at arrows for leaks.
  • Retighten if necessary, but do not overtighten.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ARCORA User Manuals

Related Manuals