OLIMPIA SPLENDID Dolceclima Air Pro 14 Heat Pump Instruction Manual

June 12, 2024
OLIMPIA SPLENDID

OLIMPIA SPLENDID Dolceclima Air Pro 14 Heat Pump

OLIMPIA-SPLENDID-Dolceclima-Air-Pro-14-Heat-Pump

Product Information

The product is called Dolceclima Air Pro.
The product is available in multiple languages: Italian (IT), English (EN), French (FR), German (DE), Spanish (ES), Portuguese (PT), Dutch (NL), Greek (EL), Polish (PL), Romanian (RO), Swedish
(SV), Finnish (FI), Norwegian (NO), Hungarian (HU), Czech (CS), Ukrainian (UK), Danish (DA).
The product contains R290 gas, which is classified as A3 flammable.
The product should be stored in a well-ventilated area that corresponds to the room size.
There are various warnings and caution messages provided in the user manual, including the risk of fire.

Product Usage Instructions

  1. Ensure that the product is stored in a well-ventilated area that matches the room size.
  2. Take note of the warnings and caution messages provided in the user manual.
  3. Familiarize yourself with the symbols and pictograms used in the manual.
  4. Use the product as intended and follow the recommended usage instructions.
  5. Be aware of the potential risks associated with using the product.
  6. If applicable, consider optional features such as WiFi connectivity, humidity control, and display boards.
  7. Follow the instructions for connecting and using any optional components.
  8. Pay attention to the recommended distances and measurements provided in the manual.
  9. Refer to the provided diagrams and labels for proper installation and connection of the product.

ILLUSTRATIONS The illustrations are grouped on the initial pages of the manual

WARNINGS

GENERAL INFORMATION First of all, we would like to thank you for choosing our appliance.
0.2 – SYMBOLS The pictograms in the next chapter provide the necessary information for correct, safe use of the machine in a rapid, unmistakable way.
0.2.1 – Editorial pictograms
Indicates that this document must be read carefully before installing and/or using the appliance.
Indicates that this document must be read carefully before any maintenance and/ or cleaning operation. Indicates that there may be additional information in attached manuals. Indicates that information is available in the user manual or in the installation manual. Indicates that the assistance personnel must handle the appliance following the installation manual. Indicates that the appliance uses inflammable refrigerant. If the refrigerant escapes and is exposed to a source of external ignition, there is a fire risk. Signals to the personnel that the operation described could cause electrocution if not performed according to the safety rules. It informs the personnel concerned that if the operation is not carried out in compliance with the safety regulations, it presents the risk of suffering physical damage. It informs the personnel concerned that if the operation is not carried out in compliance with the safety regulations, it presents the risk of burns due to contact with components at very high temperatures.
Paragraphs marked with this symbol contain very important information and recommendations, particularly as regards safety. Failure to comply with them may result in: – danger of injury to the operators – loss of the warranty – refusal of liability by the manufacturer.
Refers to actions that absolutely must not be performed.
Indicates to the personnel concerned, that it is prohibited to cover the appliance, to prevent over-heating.
EN – 2

ENGLISH

0.3 – GENERAL WARNINGS
WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS MUST ALWAYS BE FOLLOWED IN ORDER TO REDUCE RISKS OF FIRE, ELECTRIC SHOCKS
AND INJURY, INCLUDING THE FOLLOWING:
To prevent possible damages to the compressor, each start is delayed by 3 minutes with respect to the last switching off.
1. This document is restricted in use to the terms of the law and may not be copied or transferred to third parties without the express authorization of the manufacturer, OLIMPIA SPLENDID. Our machines are subject to change and some parts may appear different from the ones shown here, without this affecting the text of the manual in any way.
2. Read this manual carefully before performing any operation (installation, maintenance, use) and follow the instructions contained in each chapter.
3. Keep the manual carefully for future reference.
4. After removing the packaging, check that the appliance is in perfect condition. The packaging materials must not be left within reach of children as they can be dangerous.
5. THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES TO PERSONS OR PROPERTY CAUSED BY FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL.
6. The manufacturer reserves the right to make any changes it deems advisable to its models, although the essential features described in this manual remain the same.
7. The maintenance of equipment for conditioning such as this one may result dangerous since inside this appliance a refrigerant gas under pressure and live electrical components are present. For this reason, possible maintenance interventions (with the exception of filters cleaning) must be performed exclusively by authorized and qualified personnel.
8. Failing to comply with the instructions contained in this manual, and using the unit with temperatures exceeding the permissible temperature range will invalidate the warranty.
9. Routine maintenance of the filters and general external cleaning can be done by the user as these operations are not difficult or dangerous.
10. During assembly and at each maintenance operation, it is necessary to respect the precautions indicated in this manual and on the labels located inside or on the appliance, as well as to take all the precautions suggested by common sense and by the Safety Regulations in force in the country of installation.
11. In case of replacement of parts, use only original OLIMPIA SPLENDID parts.
12. If the unit is unused for a long period, or no-one uses the climate- controlled room, it is recommended to disconnect the electric power supply in order to prevent accidents.
13. Do not use liquid or corrosive detergents to clean the unit, do not spray water or other liquids onto the unit, since they could damage the plastic components or even cause electric shocks.
14. Do not wet the indoor unit and the remote control. Short circuits or fires may occur.
15. In case of functioning anomalies (for example: abnormal noise, bad smell, smoke, abnormal increase in temperature, electrical dispersions, etc.), immediately switch off the appliance and disconnect the plug from the power socket.
EN – 3

DOLCECLIMA AIR PRO

ENGLISH

For repair work contact solely the technical service centres authorised by the manufacturer and ask for original spare parts to be used. Failure to do this can affect the safety of the appliance.
16. Do not let the air conditioner run for a long time when the humidity is very high and a door or a windows is left open. Moisture may condense and wet or damage furniture.
17. Do not disconnect the power plug during functioning. Fire or electrical shocks hazard.
18. Do not place heavy or hot objects on top of the appliance. 19. Before electrically connecting the appliance, make sure the plate data correspond
to those of the distribution network. The power socket must be equipped with a Ground System. The plate (20) is located on the sides of the appliance (Fig.2). 20. Install the appliance according to the manufacturer’s instructions. An incorrect installation can cause damage to people, animals or property for which the manufacturer accepts no responsibility. 21. If the appliance’s plug is incompatible with the socket, have the socket replaced with a suitable one by a qualified technician, who must ascertain that the section of the socket cables is compatible with the power absorbed by the appliance. We do not recommend using adaptors and/or extension cables. If they cannot be avoided, however, they must comply with current safety regulations and their ampacity (A) must not be below the maximum ampacity of the appliance. 22. This appliance is not intended to be run via an external timer or with a separate remote control system. 23. Always and only use the appliance in a vertical position. 24. Do not obstruct the air inlet and outlet grids in any manner. 25. Do not insert extraneous items in the air inlet and outlet grids as this will create the risk of electrical shocks, fire or damages to the appliance. 26. Do not use the appliance: – with wet or damp hands; – barefoot. 27. Do not pull the power cable or the appliance itself to remove the plug from the socket. 28. Do not use this product under direct sunlight or near a heat source such as a stove, heater or radiator (Fig.3).
29. Do not use the appliance near gas equipment (Fig.3). 30. Always place the appliance on a stable, plane and levelled surface. 31. Leave at least 30cm of free space on both sides and 20cm behind the appliance and
leave at least 30cm of free space above it (Fig.1). 32. Do not place the appliance near a power socket (Fig.4). 33. The socket must be easily accessible so that the plug can be removed easily in an
emergency. 34. Do not handle the plug with wet hands. 35. Do not excessively bend, twist, pull or damage the power cord. 36. Do not run the cord under carpeting, throw rugs or runners etc. Arrange cord away
from traffic areas so that it will not be tripped over. 37. Unplug the cord when unit is not in use for an extended period of time and/or when
no one is home. 38. Do not use the appliance in particularly moist environments (bathroom, kitchen,
etc.). 39. Do not use the appliance outdoors or on wet surfaces. Avoid dropping liquids on
the appliance. Do not use the appliance near sinks and taps. 40. Do not immerse the appliance in water or in other liquids.
EN – 4

ENGLISH

41. Clean the appliance with a damp cloth; do not use abrasive products or materials. See the appropriate paragraph for the filters cleaning.
42. The most common cause of overheating is dust or lint deposit in the appliance. Regularly remove these accumulations by disconnecting the appliance from the power socket and vacuuming the grids.
43. Do not use the appliance in environments subject to significant temperature changes as condensation could form inside the appliance itself.
44. Install the appliance at at least 2 meters from other electronic devices (TV, radio, computer, dvd player, etc.) in order to avoid disturbances (Fig.6).
45. Do not use the appliance if insecticide gas has just been sprayed in the room or in the presence of burning incenses, chemical vapours or oily residues.
46. Do not use the appliance if the filters are not positioned correctly. 47. Disassembly, repair or reconversion performed by an unauthorized person could
cause heavy damages and will cancel the manufacturer warranty. 48. Do not use the appliance in case of malfunctioning or faults, if the cord or plug are
damaged, or if it has been dropped or damaged in any manner. Turn the appliance off, disconnect the plug from the socket and let it be checked by professionally qualified personnel. 49. Neither disassemble nor modify the appliance. 50. Repairing the appliance by yourself is extremely dangerous. 51. If you no longer wish to use this appliance, it must be made inoperative by cutting the power supply cable after removing the plug from the power socket. Hazardous parts of the appliance must be rendered harmless, especially as there is a risk of children playing with it. 52. Do not use tools different from those recommended by the manufacturer for the defrosting process and for the appliance cleaning. 53. The appliance is equipped with a thermal protector which preserves the circuit board in case of over-temperature. If this safety device intervenes, disconnect the plug from the power socket and wait for the appliance to completely cool down (at least 20÷30 minutes) and then reconnect the plug to the power socket and restart the appliance. If the appliance doesn’t restart, disconnect the plug from the power socket and contact an Assistance Centre. 54. Transmission frequency: 2412-2472Mhz Maximum transmitted power: <20dBm
0.4 – PROPER USE · The air conditioner must be used exclusively to produce warm* or cold air or to dehumidify air (upon choice) with the only purpose to make the environment temperature comfortable. · This appliance is only intended for a domestic use or similar. · An improper use of the appliance with possible damages caused to people, things or animals releases OLIMPIA SPLENDID from any responsibility.
EN – 5
DOLCECLIMA AIR PRO

ENGLISH

0.5 – HAZARDOUS ZONES · The climate controllers must not be installed in environments with the presence of inflammable gases, explosive gases, in very humid environments (laundries, greenhouses, etc.), or in places with other machines that generate a strong heat source, in proximity of a sources of salt water or sulphurous water. · DO NOT use gas, gasoline or other inflammable liquids near to the climate controller. · Only use supplied components (see paragraph 1.1). The use of non-standard parts may cause water leaks, electric shocks, fires and injuries or damages to things.

This product must be used exclusively according to the specifications indicated in this manual. Use different to that specified, could cause serious injuries. THE MANUFACTURER IS NOT LIABLE FOR INJURY/DAMAGE TO PERSONS/OBJECTS DERIVING FROM FAILURE TO COMPLY WITH THE REGULATIONS CONTAINED IN THIS MANUAL.

  • Only for version with heat pump

0.6 – WARNINGS FOR R290 REFRIGERANT GAS
1. THE APPLIANCE CONTAINS R290 GAS (FLAMMABILITY CLASSIFICATION A3). 2. THE APPLIANCE SHALL BE STORED IN A WELL-VENTILATED AREA WHERE THE ROOM
SIZE CORRESPONDS TO THE ROOM AREA AS SPECIFIED FOR OPERATION. 3. THE APPLIANCE MUST BE INSTALLED, USED AND STORED IN A ROOM WITH A FLOOR
SURFACE HIGHER THAN THE ONE INDICATED IN THE CHART.

Quantity of R290 gas in Kg (see data label on the appliance)
Minimum size of the site for use and storage (m2 )

0,180 0,190 0,200 0,210 0,220 0,230 0,240 0,250 0,260

9

10 10 11

11 12 12 12 13

4. THIS APPLIANCE CONTAINS A QUANTITY OF REFRIGERANT GAS R290 EQUAL TO THE ONE INDICATED IN THE DATA LABEL LOCATED ON THE APPLIANCE.
5. THE APPLIANCE SHALL BE STORED IN A ROOM WITHOUT CONTINUOUSLY OPERATING IGNITION SOURCES (FOR EXAMPLE: OPEN FLAMES, AN OPERATING GAS APPLIANCE OR AN OPERATING ELECTRIC HEATER).
6. Do not pierce or burn. 7. Be aware that the refrigerants may not contain an odour. 8. R290 is a refrigerant gas in compliance with the European directives on environment. Do not
pierce any part of the refrigerant circuit. 9. Do not use means to accelerate the defrosting process or to clean, other than those recom-
mended by the manufacturer. 10. Do not use tools different from those recommended by the manufacturer when defrosting and
cleaning the appliance. 11. If the appliance is installed, used or stored in a non-ventilated area, the room must be de-
signed to prevent the accumulation of refrigerant leaks with the consequent fire or explosion hazard due to the refrigerant combustion caused by electrical heaters, stoves or others sources of ignition. 12. Compliance with national gas regulations shall be observed. 13. Keep ventilation openings clear of obstruction. 14. The appliance shall be stored so as to prevent mechanical damage from occurring.

EN – 6

ENGLISH

15. Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification. 16. Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
17. TRANSPORT OF EQUIPMENT CONTAINING FLAMMABLE REFRIGERANTS See transport regulations.
18. MARKING OF EQUIPMENT USING SIGNS See local regulations.
19. DISPOSAL OF EQUIPMENT USING FLAMMABLE REFRIGERANTS See national regulations.
20. STORAGE OF EQUIPMENT/APPLIANCES The storage of equipment should be in accordance with the manufacturer’s instructions.
21. STORAGE OF PACKED (UNSOLD) EQUIPMENT Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations. 22. INFORMATION ON SERVICING a) Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system. b) Work procedure Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed. c) General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material. d) Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe. e) Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available at hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area. f) No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed. g) Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work.
EN – 7
DOLCECLIMA AIR PRO

ENGLISH

A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. h) Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: The charge size is in accordance with the room size within which the refrigerant containing parts are installed; The ventilation machinery and outlets are operating adequately and are not obstructed; If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected; Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded. i) Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to th

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

OLIMPIA SPLENDID User Manuals

Related Manuals