The ZTCV 850-0 is a deluxe video table-top accessory designed for use with bus
telephones with colour monitor BTCV 850-… as well as BTSV 850-03 for
conversion from a wall to a tabletop unit. It features a slip-proof console
with 2 rubber feet but without telecom socket UAE 8(8).
Mounting, installation and servicing work on electrical devices may only be
performed by a suitably qualified electrician. Additionally, please note that
modern furniture is coated with an enormous variety of different lacquer and
plastic finishes. Constituents of these materials can result in softening of
the plastic feet in table-top devices and so impair the surface of the
furniture. Please appreciate that the manufacturer is unable to accept any
liability.
It is important to avoid direct contact with the circuit board as
electrostatic charging can result in destruction of the device. The product
should only be used in dry indoor atmospheres.
Product Usage Instructions
- Connect the cores to the terminals in accordance with the circuit diagram.
- Do not remove the inserted terminating resistor at the terminals TaM and TbM.
- It is not possible to loop through the video signal in the in-house telephone with table-top units.
- Hook the housing into the base plate from above and close by exerting a slight pressure.
- To remove the housing, push the locking mechanism upwards through the hole in the table foot using a flat blade screwdriver. The circuit board and receiver remain on the upper part of the housing.
Application
Table-top accessory for bus telephones with colour monitor BTCV 850-… as well as BTSV 850-03 for conversion from a wall to a table-top unit. Slip-proof console with 2 rubber feet but without telecom socket UAE 8(8).
Electrical voltage
Mounting, installation and servicing work on electrical devices may only be
performed by a suitably qualified electrician.
Modern furniture is coated with an enormous variety of different lacquer and
plastic finishes. Constituents of these materials can result in softening of
the plastic feet in table-top devices and so impair the surface of the
furniture. Please appreciate that the manufacturer is unable to accept any
liability.
Electrostatic charging
As a result of electrostatic charging, direct contact with the circuit board
can result in destruction of the device. Direct contact with the circuit board
must therefore be avoided.
Note For use only in dry indoor atmospheres.
Scope of supply
ZTCV 850-… comprising:
- Slip-proof table foot with pre-assembled cable strain relief device
- 4 round push-on sleeves
- 4 countersunk head screws 2,5×6
- Spacer plate for height compensation in case of individually configured devices
- 8-pole connecting cables, 3 m long with Western plug
- This product information
Mounting
-
Open the device from the back by pressing in the locking lever.
-
Unscrew the pre-assembled cable strain relief device in the table foot.
-
Insert the two connecting cables with the stripped cores into the table foot from the back. Observe a cable length after the cable strain relief device of 120 mm. Screw the cable with cable strain relief device in the table foot using the two screws.
-
a. Place the telephone base plate on the table foot. Insert the cores through the large opening in the base plate.
b. In the case of a telephone with a front and rear panel, the spacer plate must be inserted between the table foot and the base plate in order to compensate for the distance. -
Break off the pre-moulded push-on sleeves from the plastic cross. Fasten the base plate using the 4 round press push on sleeves and the countersunk head screws.
Installation
-
Connect the cores to the terminals in accordance with the circuit diagram. Do not remove the inserted terminating resistor at the terminals TaM and TbM. It is not possible to loop through the video signal in the in-house telephone with table-top units.
If the Telecom junction box has a shielding terminal, this is not occupied.- If switching and control functions are executed, the contacts of the Telecom junction box may have to be configured for any occurring currents. (see Telecom junction box data sheet)
- Unassigned cores must be insulated and stored in the installation chamber on the base plate or table foot.
-
Hook the housing into the base plate from above and close by exerting a slight pressure.
-
To remove the housing, push the locking mechanism upwards through the hole in the table foot using a flat-blade screwdriver. The circuit board and receiver remain on the upper part of the housing.
Specifications
- Connecting cable: 8-core 3 m long
- Ambient temperature: +5 °C to +40 °C
S. Siedle & Söhne
Telefon- und Telegrafenwerke OHG
Postfach 1155
78113 Furtwangen
Bregstraße 1
78120 Furtwangen
Telefon +49 7723 63-0
Telefax +49 7723 63-300
www.siedle.de
info@siedle.de
© 2005/12.21
Printed in Germany
Best.-Nr. 200034731-02
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>