SIP INDUSTRIAL 05639 30 Inch Drum Fan Instruction Manual

June 12, 2024
SIP INDUSTRIAL

SIP INDUSTRIAL 05639 30 Inch Drum Fan

SIP-INDUSTRIAL-05639 30-Inch-Drum-Fan-PRODUCT

Prouct Information

  • Product Name: 30 Drum Fans
  • Manufacturer: SIP Industrial Products Limited
  • Address: Gelders Hall Road, Shepshed, Loughborough, Leicestershire LE12 9NH, United Kingdom
  • SIP Code: 05639, 05640

Contact Information:

Product Usage Instructions

Step 1: Please read and fully understand the instructions in the provided manual before operating the drum fan. Keep the manual safe for future reference.

SAFETY INSTRUCTIONS

Important: Please read the following instructions carefully, failure to do so could lead to serious personal injury and / or damage to the drum fan.

Danger / Caution: Indicates risk of personal injury and/or the possibility of damage.

Warning: Risk of electrical injury or damage!

Note: Supplementary Information

  • When using your fan, basic safety precautions should always be followed to reduce the risk of fire, electric shock, personal injury and / or damage to the fan.
  • Read all of these instructions before operating the fan and save this user manual for future reference.
  • The fan should not be modified or used for any application other than that for which it was designed; It was de-signed to safely and quietly move air in large volumes.
  • If you are unsure of its relative applications do not hesitate to contact us and we will be more than happy to ad-vise you.
  • Before operating the fan always check no parts are broken, that all screws are completely tight and that no parts are missing.
  • Always operate the fan safely and correctly.
  • KNOW YOUR FAN: Read and understand the owner’s manual and labels affixed to the fan. Learn its applications and limitations, as well as the potential hazards specific to it.
  • DO NOT USE THE FAN IN DANGEROUS ENVIRONMENTS: Do not use your fan in damp or wet locations, or expose it to rain. Always provide adequate space around the drum fan.
  • STAY ALERT: Always watch what you are doing and use common sense when placing and operating the fan. DISCONNECT THE FAN FROM THE MAINS SUPPLY: When not in use.
  • NEVER LEAVE THE FAN UNATTENDED: During operation.
  • DO NOT ABUSE THE MAINS LEAD: Never pull the mains lead to remove the plug from the mains socket, or to move the fan from place to place. Keep the mains lead away from heat, oil and sharp edges. If the mains , lead is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid unwanted hazards.
  • HAVE YOUR FAN REPAIRED BY A QUALIFIED PERSON: The fan is in accordance with the relevant safety require-ments. Repairs should only be carried out by qualified persons using original spare parts, otherwise this may re-sult in considerable danger to the user and void the warranty.
  • USE RECOMMENDED PARTS ONLY: Unapproved and untested parts may be dangerous and will invalidate the warranty.
  • DANGER! Check that the fan is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
  • WARNING! Only operate on a level and stable surface.
  • WARNING! Do not allow untrained persons to operate the fan and do not operate the fan without all co-vers etc. correctly fitted.
  • WARNING! RISK OF ELECTRIC SHOCK. Do not expose the fan to water spray, rain, dripping water or mois-ture of any kind.
  • Do not leave the fan unattended when in use. Switch the fan off and unplug from the mains supply before leaving the work area.
  • Do not allow children or animals near the drum fan, particularly when in use.
  • Ensure that the drum fan is correctly turned off when not in use and store in a safe, dry area, out of reach of children.
  • Keep all combustible materials away from this drum fan.
  • Never stand on the fan.
  • DO NOT dismantle or tamper with the fan, this may be dangerous and will invalidate the warranty.

WARNING: Risk of Electric Shock!

  • Use only the electrical power (voltage and frequency) specified on the model plate of the drum fan. If in doubt contact the manufacturer.
  • Use only a three-prong, grounded (earthed) outlet.
  • Do not touch, or operate the fan when your hands are wet.
  • Those who are not qualified electricians / engineers should not disassemble, repair or rebuild the fan.
  • DO NOT unplug the fan by pulling the mains lead. Unplug by holding the plug.
  • DO NOT use the fan when there is damage to the mains lead or plug.
  • DO NOT use the fan close to the fires.
  • To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
  • DO NOT use the fan outdoors.
  • Always check all guards to make sure they are secure before starting the fan.
  • Never insert fingers or any other object/s through the grill guard when the fan is in operation.
  • Never leave the fan unattended and ensure that children and pets are kept a safe distance from the fan.
  • Turn the fan off and disconnect it from the mains supply when moving from one location to another.
  • Turn the fan off and disconnect it from the mains supply when carrying out any repairs, maintenance or cleaning.
  • Do not use petrol or other corrosive liquids for cleaning as they may damage the fan or outer casing / grill.
  • Do not operate the fan near an open window, such as on a window sill; rain or moisture may create an electrical hazard.
  • Never modify the fan in any way.
  • Never operate the fan without all guards in place.
  • Before each use; always check that the moving parts move freely and do not catch or bind.
  • Stop operation immediately if abnormalities are noticed.
  • Always clear the surface around where the fan is to be used to avoid unwanted dust or debris being pulled through the fan.
  • If a problem with the drum fan is experienced, or if the mains lead or plug become damaged, contact your dis-tributor for repair.
  • If the drum fan is used in a place of work all rules and laws etc. relating to the use of portable electrical applianc-es should be followed.
  • Understand the operating environment; Before each use the operator should assess, understand and where pos-sible reduce the specific risks and dangers associated with the operating environment. Bystanders should also be made aware of any risks associated with the operating environment.
  • CAUTION: The warnings and cautions mentioned in this user manual can not cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be applied.
Electrical Connection

WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the fol-lowing:

  • You must check all electrical products, before use, to ensure that they are safe.
  • You must inspect power cables, plugs, sockets and any other connectors for wear or damage.
  • You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices; A residual current circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recom-mend that a residual current device (RCD) is used. It is particularly important to use an RCD with portable prod-ucts that are plugged into a supply.

Connecting to the power supply:

  • These SIP drum fans are fitted with either a standard 230v ~ 13 amp or 110v ~ 16 amp type plug. Before using the drum fan, inspect the mains lead and plug to ensure that neither are damaged. If any damage is visible have the drum fan inspected / repaired by a suitably qualified person. If it is necessary to replace the plug a heavy du-ty impact resistant plug would be preferable.
  • The wires for the plug are coloured in the following way:
    • Yellow / green Earth
    • Blue Neutral
    • Brown Live

As the colours of the wires may not correspond with the markings in your plug, proceed as follows: The wire which is coloured blue, must be connected to the terminal marked with N or coloured black. The wire which is coloured brown, must be connect-ed to the terminal, which is marked L or coloured red. The wire which is col-oured yellow / green should be connected to the terminal which is coloured the same or marked .
Always secure the wires in the plug terminal carefully and tightly. Secure the cable in the cord grip carefully.

Warning : Never connect live or neutral wires to the earth terminal of the plug. Only fit an ap-proved plug with the correct rated fuse. If in doubt consult a qualified electrician.
Note : Always make sure the mains supply is of the correct voltage and the correct fuse protec-tion is used. In the event of replacing the fuse always replace the fuse with the same value as the original.
Note : If an extension lead is required in order to reach the mains supply; ensure that this too is rated for the correct voltage and fuse rating.
Note : The cross section of the extension lead should be checked so that itis of sufficient size so as to reduce the chances of voltage drops.

Step 2: Connecting to the power supply:

  1. Inspect the mains lead and plug of the drum fan to ensure they are not damaged. If any damage is visible, have the drum fan inspected or repaired by a qualified person.
  2. If it is necessary to replace the plug, use a heavy-duty impact-resistant plug. The wires for the plug are colored as follows:
    • Live wire: [insert color]
    • Neutral wire: [insert color]
    • Earth wire: [insert color]
  3. Never connect live or neutral wires to the earth terminal of the plug. Only fit an approved plug with the correct rated fuse. If in doubt, consult a qualified electrician.
  4. Ensure the mains supply is of the correct voltage and use the  correct fuse protection. When replacing the fuse, always use a fuse with the same value as the original.
  5. If an extension lead is required, make sure it is rated for the correct voltage and fuse rating.
  6. Check the cross-section of the extension lead to ensure it is of sufficient size to reduce the chances of voltage drops.

Technical Specification

Item No.| Supply| No. of Speed Settings| Power Consumption (W) – Low| Power Consumption (W) – High| Input Current (A) – Low| Input Current (A) – High| Speed – Low| Speed – High| Noise Level (Max)| Protection| Net Weight
---|---|---|---|---|---|---|---|---|---|---|---
05639| 220-240V~ 50Hz| 2| 109W| 123W| 0.48A| 0.53A| 30| 9306 m3/hour| 10218 m3/hour| 850 rpm| 950 rpm| 70.7 dB(A)| IP20| 18.48 Kg
Item No.| 05639| 05640
---|---|---
Supply| 220-240V~ 50Hz| 110V~ 50Hz
No. of Speed Settings| 2| 2
Power Consumption (W) – Low| 109W| 111W
Power Consumption (W) – High| 123W| 123W
Input Current (A) – Low| 0.48A| 1.04A
Input Current (A) – High| 0.53A| 1.15A
Fan Ø| 30”| 30”
Air Flow – Low| 9306 m3/hour| 9284 m3/hour
Air Flow – High| 10218 m3/hour| 9777 m3/hour
Speed – Low| 850 rpm| 850 rpm
Speed – High| 950 rpm| 950 rpm
Noise Level (Max)| 70.7 dB(A)| 70.3 dB(A)
Protection| IP20| IP20
Net Weight| 18.48 Kg| 20.03 Kg

Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

SAFETY SYMBOLS USED THROUGHOUT THIS MANUAL

Danger / Caution: Indicates risk of personal injury and/or the possibility of damage.

Warning: Risk of electrical injury or damage!

Note: Supplementary Information.

SAFETY INSTRUCTIONS

Important: Please read the following instructions carefully, failure to do so could lead to serious personal injury and / or damage to the drum fan.

  • When using your fan, basic safety precautions should always be followed to reduce the risk of fire, electric shock, personal injury and / or damage to the fan.
  • Read all of these instructions before operating the fan and save this user manual for future reference.
  • The fan should not be modified or used for any application other than that for which it was designed; It was de-signed to safely and quietly move air in large volumes.
  • If you are unsure of its relative applications do not hesitate to contact us and we will be more than happy to ad-vise you.
  • Before operating the fan always check no parts are broken, that all screws are completely tight and that no parts are missing.
  • Always operate the fan safely and correctly.
  • KNOW YOUR FAN: Read and understand the owner’s manual and labels affixed to the fan. Learn its applications and limitations, as well as the potential hazards specific to it.
  • DO NOT USE THE FAN IN DANGEROUS ENVIRONMENTS: Do not use your fan in damp or wet locations, or expose it to rain. Always provide adequate space around the drum fan.
  • STAY ALERT: Always watch what you are doing and use common sense when placing and operating the fan. DISCONNECT THE FAN FROM THE MAINS SUPPLY: When not in use.
  • NEVER LEAVE THE FAN UNATTENDED: During operation.
  • DO NOT ABUSE THE MAINS LEAD: Never pull the mains lead to remove the plug from the mains socket, or to move the fan from place to place. Keep the mains lead away from heat, oil and sharp edges. If the mains , lead is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid unwanted hazards.
  • HAVE YOUR FAN REPAIRED BY A QUALIFIED PERSON: The fan is in accordance with the relevant safety require-ments. Repairs should only be carried out by qualified persons using original spare parts, otherwise this may re-sult in considerable danger to the user and void the warranty.
  • USE RECOMMENDED PARTS ONLY: Unapproved and untested parts may be dangerous and will invalidate the warranty.
  • DANGER! Check that the fan is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
  • WARNING! Only operate on a level and stable surface.
  • WARNING! Do not allow untrained persons to operate the fan and do not operate the fan without all co-vers etc. correctly fitted.
  • WARNING! RISK OF ELECTRIC SHOCK. Do not expose the fan to water spray, rain, dripping water or mois-ture of any kind.
  • Do not leave the fan unattended when in use. Switch the fan off and unplug from the mains supply before leaving the work area.
  • Do not allow children or animals near the drum fan, particularly when in use.
  • Ensure that the drum fan is correctly turned off when not in use and store in a safe, dry area, out of reach of children.
  • Keep all combustible materials away from this drum fan.
  • Never stand on the fan.
  • DO NOT dismantle or tamper with the fan, this may be dangerous and will invalidate the warranty.

WARNING: Risk of Electric Shock!

  • Use only the electrical power (voltage and frequency) specified on the model plate of the drum fan. If in doubt contact the manufacturer.
  • Use only a three-prong, grounded (earthed) outlet.
  • Do not touch, or operate the fan when your hands are wet.
  • Those who are not qualified electricians / engineers should not disassemble, repair or rebuild the fan.
  • DO NOT unplug the fan by pulling the mains lead. Unplug by holding the plug.
  • DO NOT use the fan when there is damage to the mains lead or plug.
  • DO NOT use the fan close to the fires.
  • To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
  • DO NOT use the fan outdoors.
  • Always check all guards to make sure they are secure before starting the fan.
  • Never insert fingers or any other object/s through the grill guard when the fan is in operation.
  • Never leave the fan unattended and ensure that children and pets are kept a safe distance from the fan.
  • Turn the fan off and disconnect it from the mains supply when moving from one location to another.
  • Turn the fan off and disconnect it from the mains supply when carrying out any repairs, maintenance or cleaning.
  • Do not use petrol or other corrosive liquids for cleaning as they may damage the fan or outer casing / grill.
  • Do not operate the fan near an open window, such as on a window sill; rain or moisture may create an electrical hazard.
  • Never modify the fan in any way.
  • Never operate the fan without all guards in place.
  • Before each use; always check that the moving parts move freely and do not catch or bind.
  • Stop operation immediately if abnormalities are noticed.
  • Always clear the surface around where the fan is to be used to avoid unwanted dust or debris being pulled through the fan.
  • If a problem with the drum fan is experienced, or if the mains lead or plug become damaged, contact your dis-tributor for repair.
  • If the drum fan is used in a place of work all rules and laws etc. relating to the use of portable electrical applianc-es should be followed.
  • Understand the operating environment; Before each use the operator should assess, understand and where pos-sible reduce the specific risks and dangers associated with the operating environment. Bystanders should also be made aware of any risks associated with the operating environment.
  • CAUTION: The warnings and cautions mentioned in this user manual can not cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be applied.

WARRANTY

These SIP drum fans are covered by a 12 month parts and labour warranty covering failure due to manufacturers defects. This does not cover failure due to misuse or operating the fan outside the scope of this manual – any claims deemed to be outside the scope of the warranty may be subject to charges Including, but not limited to parts, labour and carriage costs. Consumables items such as fuses are not covered by the warranty.
In the unlikely event of warranty claims, contact your distributor as soon as possible.

Note: Proof of purchase will be required before any warranty can be honoured.

CONTENTS & ACCESSORIES

  • 1x Drum Fan.
  • 1x Instruction Manual.

Note: If any of the above are missing or damaged, contact your distributor immediately.

GETTING TO KNOW YOUR DRUM FAN – 05639

SIP-INDUSTRIAL-05639-30 Inch-Drum-Fan \(5\)

Item Description Item Description
1 Speed Control Knob 5 Frame
2 Motor 6 Foot
3 Handle 7 Wheels
4 Drum Body 8 Fan Blade

GETTING TO KNOW YOUR DRUM FAN – 05640

SIP-INDUSTRIAL-05639-30 Inch-Drum-Fan \(6\)

Item Description Item Description
1 Speed Control Knob 5 Foot
2 Motor 6 Wheels
3 Drum Body 7 Fan Blade
4 Frame 8 Power Cord

OPERATING INSTRUCTIONS

SIP-INDUSTRIAL-05639-30 Inch-Drum-Fan \(7\)

Note: Always allow at least 1 metre clearance around the fan, failure to adhere to this will stop the cooling air flowing through the drum fan, this could damage the motor and void your war-ranty.

The drum fan has 2 different speed settings:

  • 0 — Stop
  • 1 — Low
  • 2 — High
  • Turn the switch to the desired position1 or 2 to start the fan.
  • Turn the switch to “0” to stop the fan running.

Note: Never Run this fan whilst it`s raining, or in any damp or wet locations, and never place it on the window sill.

WIRING DIAGRAM – 05639 SIP-INDUSTRIAL-05639-30 Inch-Drum-Fan
\(9\)

WIRING DIAGRAM – 05640 SIP-INDUSTRIAL-05639-30 Inch-Drum-Fan
\(10\)

EXPLODED DRAWING / PARTS LIST – 05639

SIP-INDUSTRIAL-05639-30 Inch-Drum-Fan \(11\)

Item Description Item Description
1 Front Guard 8 Switch Box
2 Blade Component 9 Switch Knob
3 Handle 10 Capacitor
4 Drum 11 Power Cord
5 Rear Guard 12 Triangle Knob
6 Motor 13 Bracket
7 Switch 14 Wheels

EXPLODED DRAWING / PARTS LIST – 05640

SIP-INDUSTRIAL-05639-30 Inch-Drum-Fan \(12\)

Item Description Item Description
1 Front Guard 8 Switch Knob
2 Blade Component 9 Capacitor
3 Drum 10 Power Cord
4 Rear Guard 11 Plum Knob
5 Motor 12 Bracket
6 Switch 13 Wheels
7 Switch Box

DECLARATION OF CONFORMITY (UKCA)

We SIP (Industrial Products) Ltd Gelders Hall Road Shepshed Loughborough Leicestershire LE12 9NH England As the manufacturer within England, Scotland and Wales, we de- clare that the 30” Drum Fans – SIP Part No. 05639 & 05640 Conforms to the requirements of the following regulation(s), as indicated.

  • Electrical Equipment (Safety) Regulations 2016
  • Electromagnetic Compatibility Regulations 2016
  • The Restriction of the Use of Certain Hazardous Substances in Electrical and Elec-tronic Equipment Regulations 2012

And the following harmonised standard(s)

  • BS EN55014-1:2017+A11:2020
  • BS EN61000-3-2:2019
  • BS EN61000-3-3:2013+A1:2019
  • BS EN60335-1:2012+A11:2014+A13:2017+A1:2019+A14:2019+A2:2019 BS EN60335-2-80:2003+A1:2004+A2:2009
  • BS EN62233:2008

Signed:

Mr P. Ippaso – Managing Director – SIP (Industrial Products) Ltd Date: 26/11/2022.

DECLARATION OF CONFORMITY (CE)

Declaration of Conformity
We SIP Machinery Europe Ltd Quayside Business Park Dundalk County Louth As the manufacturer’s authorised representative within the EC de-clare that the 30” Drum Fans – SIP Part No. 05639 & 05640 Conforms to the requirements of the following directive(s), as indicated.

  • 2014/35/EU Low Voltage Directive
  • 2014/30/EU EMC Directive
  • 2015/863/EU &2011/65/EURoHS Directive

And the following harmonised standard(s)

  • EN55014-1:2017+A11:2020

  • EN61000-3-2:2019

  • EN61000-3-3:2013+A1:2019
    EN60335-1:2012+A11:2014+A13:2017+A1:2019+A14:2019+A2:2019

  • EN60335-2-80:2003+A1:2004+A2:2009

  • EN62233:2008

Signed:

Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate recycling bin.
Never dispose of electrical equipment or batteries in with your domestic waste. If your supplier offers a disposal facility please use it or alternatively use a recognised recycling agent. This will allow the recycling of raw materials and help protect the environment.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SIP INDUSTRIAL User Manuals

Related Manuals