WARNINGS

1. The appliance contains R32 gas (A2L flammability classification). 2. Comply with current regulations (e.g. the national gas standard). 3. Take care as R32 refrigerant is odourless. Pay attention to the fact that appliances with inflammable
refrigerant gas cannot be installed in small rooms. The dimensions accepted for the room depend on the height of installation of the appliance with respect to the floor and the total amount of refrigerant gas. For details, refer to the relative table in the manual. 4. This appliance can be used by children aged from 8 years and above and person with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. (be applicable for the European Countries). 5. If the power cable is damaged, it must be replaced by the manufacturer or by its technical support service or by similarly qualified personnel, to prevent any risk to the user. 9. To prevent the risk of an electric shock it is mandatory to switch off the main switch before performing the electrical connections or any maintenance operation to the appliances. 7. During installation, comply with the minimum clearances shown in figure 8. Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. 9. The appliance shall be stored in a room without continuously operating ignition sources for example: open flames, an operating gas appliance or an operating electric heater. Do not pierce or burn. 10. DO NOT reuse previously used joints

DISPOSAL

This symbol on the product or its packaging indicates that the appliance cannot be treated as normal domestic trash, but must be handed in at a collection point for recycling electric and electronic appliances. Your contribution to the correct disposal of this product protects the environment and the health of your fellow men. Health and the environment are endangered by incorrect disposal. Further information about the recycling of this product can be obtained from your local town hall, your refuse collection service, or in the store at which you bought the product. This regulation is valid only in EU member states.

ILLUSTRATIONS The illustrations are grouped on the initial pages of the manual

0 – WARNINGS
0.1 – GENERAL INFORMATION First of all, we would like to thank you for choosing our appliance.
0.2 – SYMBOLS The pictograms in the next chapter provide the necessary information for correct, safe use of the machine in a rapid, unmistakable way.
0.2.1 – Editorial pictograms
Indicates that this document must be read carefully before installing and/or using the appliance.
Indicates that this document must be read carefully before any maintenance and/ or cleaning operation. Indicates that there may be additional information in attached manuals. Indicates that information is available in the user manual or in the installation manual. Indicates that the assistance personnel must handle the appliance following the installation manual. Indicates that the appliance uses inflammable refrigerant. If the refrigerant escapes and is exposed to a source of external ignition, there is a fire risk. Signals to the personnel that the operation described could cause electrocution if not performed according to the safety rules. It informs the personnel concerned that if the operation is not carried out in compliance with the safety regulations, it presents the risk of suffering physical damage. It informs the personnel concerned that if the operation is not carried out in compliance with the safety regulations, it presents the risk of burns due to contact with components at very high temperatures.
Paragraphs marked with this symbol contain very important information and recommendations, particularly as regards safety. Failure to comply with them may result in: – danger of injury to the operators – loss of the warranty – refusal of liability by the manufacturer.
Refers to actions that absolutely must not be performed.
Indicates to the personnel concerned, that it is prohibited to cover the appliance, to prevent over-heating.
EN – 2

ENGLISH

0.3 – GENERAL WARNINGS
WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS MUST ALWAYS BE FOLLOWED IN ORDER TO REDUCE RISKS OF FIRE, ELECTRIC SHOCKS
AND INJURY, INCLUDING THE FOLLOWING:
To prevent possible damages to the compressor, each start is delayed by 3 minutes with respect to the last switching off.
1. This document is restricted in use to the terms of the law and may not be copied or transferred to third parties without the express authorization of the manufacturer, OLIMPIA SPLENDID. Our machines are subject to change and some parts may appear different from the ones shown here, without this affecting the text of the manual in any way.
2. Read this manual carefully before performing any operation (installation, maintenance, use) and follow the instructions contained in each chapter.
3. Make all personnel involved in transport and installation of the machine aware of these instructions.
4. THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES TO PERSONS OR PROPERTY CAUSED BY FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL.
5. The manufacturer reserves the right to make any changes it deems advisable to its models, although the essential features described in this manual remain the same.
6. The installation and maintenance of air-conditioners like this one may be hazardous as they contain a cooling gas under pressure as well as powered parts. Therefore, the installation, first startup and subsequent maintenance should be carried out exclusively by authorized, qualified personnel.
7. Failing to comply with the instructions contained in this manual, and using the unit with temperatures exceeding the permissible temperature range will invalidate the warranty.
8. Routine maintenance of the filters and general external cleaning can be done by the user as these operations are not difficult or dangerous.
9. During installation and maintenance, respect the precautions indicated in the manual, and on the labels applied inside the units, as well as all the precautions suggested by good sense and by the safety regulations in effect in your country.
10. Perform installation and maintenance using equipment that is suitable for inflammable gas.
11. Always wear gloves and protective goggles when performing any operations on the refrigerating side of the units.
12. Air conditioners must not be installed in places containing inflammable gasses, explosive gasses, or in very humid environments (laundries, greenhouses, etc.), or in places where there are machines that generate very great heat.
13. In case of replacement of parts, use only original OLIMPIA SPLENDID parts.
14. IMPORTANT! To prevent any risk of electrocution, always disconnect the main circuit breaker before making electric connections or performing any maintenance on the units.
EN – 3
ALYAS E INVERTER

ENGLISH

15. Lightening, cars in the vicinity and mobile phones can cause malfunctioning. Disconnect the unit electrically for a few seconds and then re-start the air conditioner.
16. On rainy days, it is recommended to connect the electric power supply in order to prevent damage caused by lightening.
17. If the unit is unused for a long period, or no-one uses the climate- controlled room, it is recommended to disconnect the electric power supply in order to prevent accidents.
18. Do not use liquid or corrosive detergents to clean the unit, do not spray water or other liquids onto the unit, since they could damage the plastic components or even cause electric shocks.
19. Do not wet the indoor unit and the remote control. Short circuits or fires may occur.
20. In the event of operating anomalies (e.g. strange noise, bad odour, smoke, abnormal temperature rise, electric dispersions, etc.) disconnect the electric power supply immediately. Contact the local dealer.
21. Do not let the air conditioner run for a long time when the humidity is very high and a door or a windows is left open. Moisture may condense and wet or damage furniture.
22. Do not plug or unplug the power supply plug during operation. Fire and electric shocks risk.
23. Do not touch (operation) the product with wet hands. Fire and electric shocks risk.
24. Do not place a heater or other appliance near the power cable. Fire and electric shocks risk.
25. Make sure water does not enter the electrical parts. It could cause fires, product failure or electric shocks.
26. Do not open the air inlet grid during appliance operation. Risk of injury, electric shock or damage to the product.
27. Do not block the air inlet or outlet; the product could be damaged.
28. Do not insert hands or other object through air inlet or outlet while the product is operated. The presence of sharp and moving parts could cause injury.
29. Do not drink the water drained from the product. It is not sanitary could cause serious health issues.
30. When there are gas leaks from other units, ventilate the room well before activating the air conditioner.
31. Do not disassemble or modify unit. 32. Ventilate the room well when used together with a stove, etc. 33. Do not use for special purposes. 34. The persons that work or intervene on a cooling circuit, must be in possession
of suitable certification, issued by an accredited assessment body. This must attest skill in safely handling refrigerants in compliance with assessment specification acknowledged by sector associations.
EN – 4

ENGLISH

35. Do not emit R32 gas into the atmosphere; R32 is a fluorinated greenhouse gas with a Global Warming Potential (GWP) = 675.
36. The appliances described in this manual are in compliance with the applicable European Directives and successive amendments.
37. The appliance contains A2L inflammable gas. For the correct method of installation, see paragraph “2.1”.
0.4 – NOTES REGARDING FLUORINATED GASES · This climate control appliance contains fluorinated gas. For specific information regarding the type and quantity of gas, refer to the data plate affixed to the unit. · The installation, assistance, maintenance and repair of the appliance, must be performed by a qualified certified technician. · Product removal and re- cycling operations must be performed by a qualified certified technician. · If the system has a leak-detection device installed, the checks for leaks must be performed at least every 12 months. · When the unit is checked for leaks, keeping a record of all inspections is highly recommended.
0.5 – PROPER USE · The air-conditioner should be used for the exclusive purpose of producing hot or cool air (on demand) for the sole purpose of obtaining a comfortable temperature in the room. · Improper use of the machine (outside and inside units) causing damage to persons, property or animals relieve OLIMPIA SPLENDID of any liability.
0.6 – HAZARDOUS ZONES · The climate controllers must not be installed in environments with the presence of inflammable gases, explosive gases, in very humid environments (laundries, greenhouses, etc.), or in places with other machines that generate a strong heat source, in proximity of a sources of salt water or sulphurous water. · DO NOT use gas, gasoline or other inflammable liquids near to the climate controller. · The climate controller does not have a fan for the introduction of fresh outdoor air into the room; ventilate by opening doors and windows. · Always install circuit breaker and a dedicated power circuit.
This product must be used exclusively according to the specifications indicated in this manual. Use different to that specified, could cause serious injuries. THE MANUFACTURER IS NOT LIABLE FOR INJURY/DAMAGE TO PERSONS/OBJECTS DERIVING FROM FAILURE TO COMPLY WITH THE REGULATIONS CONTAINED IN THIS MANUAL.
EN – 5
ALYAS E INVERTER

ENGLISH

1 – DESCRIPTION OF THE APPLIANCE
1.1 – LIST OF THE COMPONENTS SUPPLIED
The units making up the climate control system are packaged individually in cardboard boxes. Individual unit packages can be transported by hand by two members of personnel, or loaded onto a transport trolley; up to max. three packages stacked for indoor units and individually for outdoor units.
The parts indicated below are included in the supply. The other items necessary for installation must be purchased.

1. Outdoor unit
2. Indoor unit 3. Plate fixing screw 4. Plugs 5. Condensate drain fitting (quantity 1) 6. Gasket (quantity 1)

A

1

7. Indoor unit fixing plate 8. Remote control 9. Battery for remote control
quantity 2 – AAA type x 1.5V 10. Instruction booklet

1.2 – MATERIAL NECESSARY NOT SUPPLIED
For correct installation of the appliance, components that have not been supplied must be used. a. Connection pipes unit (water side) b. Connection pipes unit (gas side) c. Magnetic ring

1.3 – STORAGE
Store the cartons in a closed environment protected against atmospheric agents and raised off the floor by planks or a pallet.
TO NOT TURN THE CARTON UPSIDE DOWN.

EN – 6

ENGLISH

1.4 – RECEIPT AND UNPACKING
The packaging is made up from suitable material and performed by expert personnel. The units are delivered complete and in perfect condition. However, for he quality control of the transport services, follow the warnings below: a. On receipt of the packages, check whether the packaging is damaged. If this is the case, withdraw the
goods with reserve, producing photographic proof and any apparent damage. b. Unpack, checking the presence of the individual components with the packing lists. c. Control that all components have not undergone damage during transport. If this is the case, inform the
carrier by registered letter with acknowledgement of receipt within 3 days of receiving the goods, presenting photographic documentation. d. Pay attention when unpacking and installing the equipment. Sharp parts can cause injury. Pay particular attention to the edges of the structure and the fins of the condenser and evaporator. e. Send the same information by fax also to OLIMPIA SPLENDID.
No information concerning damage undergone can be taken into consideration after 3 days from delivery.
For any controversy the court of jurisdiction will be BRESCIA.
Keep the packaging for at least the duration of the warranty period, for any shipments to the after-sales centre for repairs. Dispose of packaging in compliance with the regulations in force regarding waste disposal.
2 – INSTALLATION
2.1 – INSTRUCTIONS FOR INSTALLATION
To obtain the best results and optimum performance, follow the instructions for correct installation provided in this manual.
The appliance contains A2L inflammable gas.
The appliance must be installed, activated and kept in an environment with area exceeding 4 m2. The appliance must not be installed in a non-ventilated area, whenever the surface is less than 4 m2.
Failure to apply the regulations indicated, which can cause unit malfunctioning, relieve OLIMPIA SPLENDID from any form of warranty and any damage/injury caused to persons, animals or objects.
The electrical system must comply with the regulations and rating data in the technical sheet, with good grounding.
Do not install, remove, or reinstall the unit by yourself (customer). There is risk of fire, electric shock, explosion, or injury.
For installation, always contact the dealer or an Authorized service center. There is risk of fire, electric shock, explosion, or injury.
Be sure the installation area does not deteriorate with age. If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
Install the unit securely in a place which can bear the weight of the unit.
EN – 7
ALYAS E INVERTER

ENGLISH

Do not install the unit in a place where a flammable gas leaks.
2.2 – CHECKS TO PERFORM BEFORE INSTALLATION a. Checks at the area Before starting to work on the systems containing inflammable refrigerants, safety checks are necessary to reduce the risk of ignition to a minimum. To repair a refrigeration system, the following precautions must be complied with before working on the system.
b. Work procedure The job must be performed according to a controlled procedure in a way to reduce the risk of the presence of inflammable gas or vapour to a minimum during the performance of the job.
c. General work area All maintenance personnel and those working in the local area, must be trained regarding the job performed. Do not work in tight spaces. The area around the work area must be isolated. Guarantee that the conditions inside the area are safe by verifying the inflammable material.
d. Check the presence of refrigerant The area which must be controlled with a specific coolant detector before, during and after carrying out the work so as to ensure that the technician is informed about the presence of potentially flammable atmosphere. Check the leak detector equipment used is suitable for use with inflammable refrigerants, i.e. does not cause sparks, is suitably sealed or intrinsically safe.
e. Presence of extinguishers Whenever work must be performed on the refrigeration system at high temperatures or on relative components, a suitable fire-prevention system must be prepared. Position CO2 or dry powder extinguishers in proximity of the loading area.
f. No source of ignition No-one working in the refrigeration systems and exposed to contact with the piping that contains or contained inflammable refrigerant, must use sources of ignition in order to prevent the risk of fire or explosion. Every possible source of ignition, among which cigarette smoke, must be kept at a due distance from the place of installation, repair, removal or disposal, where there is a risk of the refrigerant liquid leaking into the surrounding space. Before performing the job, the area surrounding the appliance must be controlled in order to ascertain that there are no inflammable substances or risks of ignition present. NO SMOKING signs must be displayed.
g. Ventilated area Make sure that the area is open or suitably ventilated before interacting with the system or performing any operation at high temperatures. Ensure constant ventilation during the operations period. Ventilation must safely disperse all refrigerant released and, if possible, expel it outside into the atmosphere.
h. Refrigeration system checks If modified, the electric components must be suitable for the purpose and compliant with the correct specifications. Always follow the manufacturer’s guide lines relative to maintenance and technical after-sales
EN – 8

ENGLISH

assistance. If in doubt, consult the manufacturer’s technical after-sales service. The plants that use inflammable refrigerants must be subjected to the following verifications: · the dimension of the load must be compliant with the chamber in which the components
containing the refrigerant are installed; · the plants and ventilation outlets must operate adequately and not be obstructed; · if an indirect refrigeration circuit is in use, check the presence of refrigerant in the secondary
circuit; the marking on the systems must be visible and legible; · illegible markings and signs must be corrected; · the pipe or refrigeration components must be installed in a position where it is improbable
that they are exposed to substances that could corrode the components containing the refrigerant, unless the components are manufactured with intrinsically corrosion resistant materials or are appropriately protected from corrosive agents.
i. Check the electric devices The repair and maintenanc