SECURITY BRANDS Ridge RTE Request-to-Exit Station User Guide
- June 12, 2024
- SECURITY BRANDS
Table of Contents
QUICK START GUIDE Model14-RTE433
NEED HELP
Call 972-474-6390
Email
techsupport@securitybrandsinc.com
We are available Mon–Fri / 8am–5pm Central
START HERE
-
Carefully unpack box.
-
Make sure you have all items shown here.(Screwdriver not shown)
What’s what?
Important components labeled
RTE Unit Front Panel(Front)
RTE Unit Front Panel(Back)
Internal wiring not shown for clarity.
Transceiver
Shown with cover removed.
Internal wiring not shown for clarity.
-
Unlock and remove Front Panel of RTE Unit; then using included Carriage Bolts and Hex Nuts, attach unit to pedestal as shown.
-
Using Tek screws, zip ties, or other means of securing, attach Transceiver to inside wall or another surface inside gate operator.
CAUTION!
The Transceiver is not weatherproof and must be mounted inside a weatherproof
enclosure. Internal components can be damaged if exposed to the elements.
Failure to comply will VOID WARRANTY.
WARNING!
AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH!
ALWAYS CHECK that the GATE PATH IS CLEAR BEFORE OPERATING!
REVERSING or other SAFETY DEVICES SHOULDALWAYS BE USED!
- a Connect Transceiver
Gate Operator Timer-to-Close OFF
Consult gate operator or door opener manual for exact connections.
Terminals vary widely across manufacturers and models.
**5bConnect Transceiver
Gate Operator Timer-to-Close ON
Consult gate operator or door opener manual for exact connections. Terminals
vary widely across manufacturers and models.
CAUTION!**
A closing gate can cause injury to persons or damage to property.
ALWAYS USE SAFETY DEVICES!
- a Remove Transceiver cover; then hold down Programming Button on circuit board for 3 seconds and let go.
6b Remove RTE Unit Front Panel.
6c Hold down both Pairing Buttons until Status LED flashes. Let go of Button 2, and continue holding Button 1 only until Status LED flashes again.
6d Relay on Transceiver should click and Programming LED should go out.
Pairing is now complete.
CHECK THAT THE GATE PATH IS CLEAR BEFORE COMPLETING THIS STEP AS IT TRIGGERS
THE RELAY!
- Press Exit Button on RTE Unit and confirm gate/door opens.
(If nothing happens, repeat Step 6. If gate/door is held open, see Troubleshooting section on Page 4.)
CHECK THAT THE GATE PATH IS CLEAR BEFORE COMPLETING
THIS STEP AS IT TRIGGERS THE RELAY!
INSTALLATION COMPLETE!
Your system is ready to use.
A The RTE Unit can be disabled and re-enabled at any time by taking the Key Switch Keys and using the Key Switch located below the Exit Button.
B Transceiver Reset Procedure
This procedure is used to unpair all devices from the Transceiver.
Step 1 – Remove screws and remove Transceiver cover.
Step 2 – Press and hold Programming Button until Programming LED starts to
flash.
Button must be held for about 30 seconds. Once flashing stops, all devices have
been unpaired from Transceiver and reset is complete.
Step 3 – Replace Transceiver cover and secure screws.
Troubleshooting
RTE U nit is holding gate/door open
IMPORTANT: GATE/DOOR MUST BE CLOSED BEFORE COMPLETING THIS PROCEDURE!
Step 1 – Press Exit Button on RTE Unit to close gate/door if it is not already
closed.
Step 2 – Hold down both Pairing Buttons and pay attention to Status LED.
Step 3 – When Status LED flashes twice, continue holding BOTH buttons.
Step 4 – When LED flashes twice again, continue holding Button 1 ONLY until
Status LED flashes multiple times.
Now the RTE unit should only hold the gate/door open momentarily.
© 2022 Security Brands, Inc. All rights reserved.
QSG-14RTE433-EN Rev. E (9/2022)