Chacon 34151 Methane Gas Detector User Manual
- June 12, 2024
- CHACON
Table of Contents
- Chacon 34151 Methane Gas Detector
- WHAT’S IN THE BOX
- Introduction
- Overview of the product
- Indication of product operation
- Advice – installation locations
- Troubleshooting
- Maintenance advice
- Preventive actions for heating, hot water and in the kitchen
- Technical specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Chacon 34151 Methane Gas Detector
WHAT’S IN THE BOX
Introduction
Thank you for using this product.
- Please read all instructions carefully before using the product.
- Do not attempt to disassemble or repair the product yourself, otherwise, the product will be out of warranty.
- This alarm has been designed and tested to detect gas leaks in a residential environment. It implements the EN 50194-1:2009 standard.
- This gas leak detector is designed to detect methane (CH4), biogas, and natural gas. It cannot be used to detect smoke, carbon monoxide or carbon dioxide.
Overview of the product
- Status indicator
- Lifetime indication
- Test /Alarm OFF button
- Loudspeaker
- Gas leak detection sensors
- Power cable
- Mounting plate
Product Installation
This detector is suitable for indoor use only. This device is recommended near your cooker, water heater, and near any gas-fired source. It should be installed 1m~4m from the gas appliance and maximum 30 centimeters from the ceiling.
Tip: It is advisable to check that the device is working properly before installing the detector on its mounting plate. Make sure that the location is close to a power source (socket).
- Ceiling
- Methane Gas Detector
- Kitchen ventilator
- Gas stove
- Ground
- Ball valve
- Gas meter
- Inlet ball valve
- Gas
Indication of product operation
Connecting the device to the power source
When you plug in the detector, the status indicator LED flashes green. Then it automatically goes into warm-up mode for 3 minutes. During this time, the unit cannot detect gas leaks. After 3 minutes, the green LED will light up to let you know that it is operational and ready for use.
The status indicator turns red
When the gas concentration value in the air reaches the set alarm point, the
detector enters the alarm mode. An audible alarm of 85dB will sound and the
status indicator will flash red. Open the windows immediately and turn off the
gas valve. Do not turn on or plug in any electrical appliances. If the alarm
does not stop, please leave your home, and call for help. If necessary, ask
your electrical and gas inspection expert to come and check your installation.
Note: In the alarm state, when the gas concentration is below the safe value, the detector automatically disarms the alarm.
Failure warning
If the LED on the status indicator is yellow and lights up continuously and
beeps, it means that the detector is defective and cannot detect properly,
please contact the distributor for repair.
Tip: We advise you to check the device daily. To do so, please press the central button once, the detector will enter the alarm simulation mode and will emit an audible and luminous alarm signal, the red LED will flash and beep, then it will return to the normal detection state.
End of life warning
If the lifetime indicator flashes 3 times continuously and at the same time
beeps 3 times, the lifetime of the sensor has expired. Please contact your
dealer if your warranty is still valid or get a new sensor.
Device status summary
Mode | LED indicator | Lifetime indicator | Alarm |
---|---|---|---|
Preheat mode | Flashing green LED | / | / |
Normal mode | Continuous green LED | / | / |
Test mode | Red LED flashing | / | Beeps 4x |
--- | --- | --- | --- |
Fault mode | Continuous yellow LED | / | Continuous beep |
Alarm mode | Flashing red led | / | Beeps 4x repeating |
End of product life | / | Flash | Beeps 3x repeatedly |
Advice – installation locations
We recommend that you install the gas leak detector near your cooker, water heater and near all gas sources. Methane (or town gas), biogas or natural gas is lighter than air and therefore rises, so place your device of about 30 cm from the ceiling. To avoid damage to the product and to prevent false alarms, do not install the unit in the following locations:
- Air inlet/outlet areas, exhaust fans, doors/windows with strong air circulation.
- Areas with moisture and water drops, e.g. in your bathroom.
- Areas directly above a source of heat or steam.
Note: If the room must be painted or renovated, please install the detector after the renova-tion or painting work.
Troubleshooting
Note: For any faults that cannot be resolved by yourself, do not dismantle the detector, please contact the distributor for advice.
Faulty | Possible reason(s) | Action(s) to be taken |
---|---|---|
The green light of the power source is not on | Power source cable not connec- | |
ted properly | Check and connect the cable to the power source correctly | |
Power source indicator damaged or circuit failure | Contact the distributor |
for repair
No audible and visual alarm during self-test| Circuit failure| Contact the
distributor for repair
---|---|---
No response to detected gas| Still preheating| Wait for the warm-up to finish
Maintenance advice
The product must be kept clean when in use, otherwise its performance will be affected and may even damage the alarm. It should be cleaned and tested at least once a month.
- Please clean dust or oil contamination on the surface of the detector regularly with a soft, dry brush or cloth. After cleaning, reinstall the detector on its base plate and perform a function check.
- After long storage or transportation, please turn on the detector and wait 24 hours or more for optimum performance.
- This product cannot be used or stored in an environment containing corrosive gases (such as chlorine)
- The presence of large amounts of cigarette smoke, alcohol, or volatile organic compounds such as petrol, perfume or paints in the room may trigger the detector’s alarm.
- The detector must be connected to a stable power source.
Note: In a normal operating environment, the solid-state sensor can operate for 5 years.
Preventive actions for heating, hot water and in the kitchen
- Have your flues and chimneys swept once a year, which is the minimum requirement, or twice for extra precaution.
- Have your installation checked regularly, for example as part of a maintenance contract. It is also compulsory to have your boiler serviced every year.
- Clean the ventilation grilles regularly and never place a piece of furniture, a towel, or any other object in front of a ventilation opening so as not to obstruct the escape of gases.
- Ventilate your home regularly.
- Turn off the natural gas tap every time you leave for the weekend or on holiday.
- Clean the burners of your gas cooker regularly: a blue flame is a guarantee of safety.
- If your cooker is connected via a flexible tube, replace it with a flexible tube with mechanically screwed ends, which is very difficult to tear off; if you already have a flexible tube, check its validity date.
CAUTION: If you detect a leak, ventilate immediately, turn off the natural gas supply, and avoid actions that could cause a spark (e.g. touching switches or circuit breakers, turning on the light, making a phone call from a landline or mobile phone, etc.) If the leak is ignited, there is no longer any risk of explosion: if possible, close the appliance’s supply valve or the natural gas supply, wet the nearby surfaces, evacuate the building, and call for help.
Technical specifications
Gas detected | methane (CH4), biogas and natural gas |
---|---|
Size (LWH) | 112mm86mm33.5mm |
Operating voltage | AC 100V~220V/50Hz~60Hz |
Power consumption | ≤4W |
Operating environment | Temperature: 0°C~55°C |
Relative humidity: <95% (non-condensing) | |
Ambient pressure: 86kPa~106kPa | |
Storage temperature | -25°C~55°C |
Response time | ≤30s |
Sensor type | semi-conductor |
Sensor lifetime | 5 years |
Alarm value | 7%LEL±3%LEL |
Alarm mode | Sound + light |
Alarm sound level | ≥85dB |
Installation | Wall mounted |
Standard | EN 50194-1:2009 |
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>