TECHNICAL DATA

MODEL VT-DL0508
WATTS 5W-8W (Changeable)
BEAM ANGLE 60°
CRI >80(>86 at 3000K & 4000K)
DF >0.93 at 8W (>0.86 at 5W)
COLOR 2700K-6000K
IP RATING IP65(Bezel), IP20(Body)
CUT OUT SIZE Ø65mm
OPERATION TEMPERATURE -20 to +45°C
BODY TYPE Aluminium + Iron
DIMENSION Ø90x45x65mm
INPUT POWER AC:200~240, 50Hz
WATTS COLOR
--- ---
5W 2700K
3000K 520LM
4000K 540LM
6000K 530LM
8W 2700K
3000K 765LM
4000K 830LM
6000K 800LM
  • QUICK CONNECTOR
    Connector

  • 30–60–90 MIN Fire Rated

  • Dimmable

  • Warranty

INTRODUCTION & WARRANTY

Thank you for selecting and buying V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any another query, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at the best. The warranty is valid for 3 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. The products are suitable for 10-12 Hours Daily operation. Usage of product for 24 Hours a day would void the warranty. This product is warranted for manufacturing defects only.

NOTE: Item is Insulation coverable
Symbol

Non-replaceable control gear

Non-replaceable light source

WARNING!

  1. Please make sure to turn off the power before starting the installation.
  2. The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced.
  3. Installation must be performed by a qualified person.
  4. If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
  5. Proper grounding should be ensured throughout the installation.
  6. For Indoor Purpose Only

 This marking indicates that this product should not be disposed of with other household wastes.

 Caution, risk of electric shock.

INSTALLATION INSTRUCTION

Installation Instruction
Installation Instruction
Installation Instruction

  1.  Switch off the power before starting the installation.
  2. Cut a hole as per the cutout 70mm (Ref to Fig1)
  3. Make the electrical connections to the terminal block. (Ref to Fig2)
  4. Holding the spring clips on the side of the fitting, insert the fitting into the hole and allow the spring to pull the fitting into the ceiling. (Ref to Fig3)
  5. Switch on the power and test if the light is working properly.