Warning Icon
WARNING
! The Led Moving Bar (LMB) has a powerfull tilt motor. The torque reaction when the head is tilted suddenly can cause the base to move if the fixture is standing unsecured on a surface. Do not apply power to the LMB unless the baase is securely fastened to a surface or to rigging hardware.\


WARNING
! Use 2 clamps to rig the fixture. Do not hang the fixture from only one clamp. Lock each clamp with both 1/4-turn fasteners. Fasteners are locked only when turned a full 900 clockwise.

WARNING ! When clamping the fixture to a truss or other structure at any other angle than with the yoke hanging vertically downwards, use two clamps of half-coupler type. Do not use any type of clamp that does not completely encircle the structure when fastened.


WARNING
! Position or shade the bar so that the front lens will not be exposed to sunlight or any other strong light source from any angle – even for a few seconds. See Figure 1. The LMB lens can focused the sun’s rays, creating a potential fire hazard and causing damage.

IMPORTANT Icon
IMPORTANT
! Do not point strong light output from other fixtures at the LMB, as intense illumination can damaged the display
Instructions

INTRODUCTION

THANK YOU FOR PURCHASING StrobeFX 1000 IP65. FOR SAFETY REASONS AND TO ENSURE THE TROUBLE-FREE OPERATION, CAREFULLY READ THE INSTRUCTIONS.

SAFETY INFORMATION

  • Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruction booklet.
  • Unpack and check carefully there is no transportation damage before using the fixture.
  • Before operating, ensure that the voltage and frequency of power supply match the power requirements of the fixture. It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
  • Disconnect main power before servicing and maintenance.
  • Use safety chain when fixes this fixture. Don’t handle the fixture by taking its head only, but always by taking its base.
  • Maximum ambient temperature is: 40°C Don’t operate it where the temperature is higher than this.
  • In the event of serious operating problem, stop using the fixture immediately. Never try to repair the fixture by yourself.
  • Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
  • Do not connect the device to any dimmer pack.
  • Do not touch any wire during operation and there might be a hazard of electric shock.
  • To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture.
  • The housing must be replaced if they are visibly damaged.
  • Do not look directly at the light spot while the fixture is on.

PRODUCT INFORMATION

  • Light Source: 12 RGB sections (5050 o.5W RGB 3in1 560 pcs.), 12 Strobo sections 3535 5W 6500K, 144 pcs. Cool-White).
  • Power consumption: 1000W
  • Power supply voltage: 100-240V, 50/60Hz AC
  • TILT range: 185°
  • LED macro effect
  • Operating modes: DMX512, Manual, Auto, Sound-controlled, Master/Slave, RDM Sound active, Art-Net
  • DMX channel mode 14/23/68/5 net
  • IP Rating: IP65
  • Housing made: ABS
  •   Cooling: Active
  •   AC IN/OUT: PowerCon TRUE1
  • 3-Pin XLR DMX Input/Output
  • Ethercon Input/Output
  • Net Weight: 11.2 kg
    • Dimensions: H(32.6)xW(13.7)xD(50.2) cm

INSTALLATION

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable
INSTALLATION

that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it.

The fixture may be installed in any orientation, but if installed horizontally with a downward beam-angle, water can potentially pool in the fan wells. Under normal operation the moisture will evaporate. However, in locations with high rainfall, you may wish to fabricate a rain shield above the fixture, or modify the position and orientation of the fixture to minimize pooling.

Two quarter-turn brackets are supplied with the fixtre if it is to be  flown above the ground. Rig the fixture to a support truss or structure using the supplied brackets and suitable clamps.

Fasten a safety cable between the support structure and the attachment point on the fixture. The safety cable must be able to bear at least 10 times the weight of the fixture.
Installations Instructions
Installations Instructions

CONNECTION

The device is equipped with the following interfaces:

  1. DMX (in/out): XLR 3(5)-pin socket
  2. Power (in/out): powerCON TRUE1 socket

The connection is performed using cable with XLR-female -> XLR-Male plugs.

CAUTION! At the last fixture, the DMX signal has to be terminated with a terminator. Solder a 120Ω resistor between signal (-) and signal (+) into a XLR plug and plug it in the DMX output of the last fixture.
CONNECTION

Diagram of connection of devices by DMX cable.

DMX cable

IMPORTANT! The maximum number of devices connected in series via power cable is 3 pcs.

The connection is performed using power cable with powerCON TRUE1 connector (included). The device must be operated by qualified personnel.

CAUTION! In the case of cable damage do not attempt to repair. Replacement or repair can be made only on the manufacturer or by a person with appropriate permissions

Using lamp, the change rate of power voltage should be within ±10%, if the voltage is too high, it will shorten the light’s life; if it’s not enough, the lamp will be dark. Please restart it after turning off light for 20 minutes until full-cooling. Frequent switching will reduce the life span of lamps and bulbs; intermittent using will improve the life of bulbs and lamps.

Voltage Specification.

Input Voltage Amperage Frequency Total Power
100-240[V] AC 3.36[A] 50/60[Hz] 1000[W]

Control Menu
CONNECTION

Menu access password: UP – DOWN – UP – DOWN – ENTER

  • Press button UP or DOWN if you want to browse through the various
  • Setup Options.
  • Press button ENTER to save your settings or enter the next menu.
  • Press UP or DOWN to shift.
  • Press button Menu will return to the upper menu one by one.

Set DMX Address

  • Press MENU to unlock screen, then select the DMX Address and press ENTER
  • Showning Set DMX Address 001, Press the UP or DOWN key to incrase or decrease the DMX address value.
  • Press ENTER to save and Exit, Press Cancel does not save and Exit.

DMX CHART

DMX CHART

CHANNEL MODE FUNCTION DMX VALUE DETAILS
14 23 68
1 TILT 0-255 -92° – 92°
2 TILT Fine 0-255 Coarse tilt + 0- 1.2°
3 WHITE BEAM Dimmer 0-255 Intensity 0- 100%
4 WHIE BEAM Strobe duration 0-255 Flash duration 7-650 ms
5 WHITE BEAM Strobe rate 0-255 Flash rate 0.289- 16.67 Hz
CHANNEL MODE FUNCTION DMX VALUE DETAILS
14 23 68
6 WHITE BEAM Strobe selection 0-56-4243-8586-128129-171172-214215-255 No

strobe Strobe type 1Strobe type 2Strobe type 3Strobe type 4Strobe type 5Strobe type 6
7| CONTROL| 0-250251-255| ResetNo function
8| PLATE RGB Dimmer| 0-255| Intensity 0-100%
9| PLATE RGB Strobe duration| 0-255| Flash duration 7-650 ms
10| PLATE RGB Strobe rate| 0-255| Flash rate 0.289- 16.67 Hz
11| PLATE RGB Strobe selection| 0-56-4243-8586-128129-171172-214215-255| No strobe Strobe type 1Strobe type 2Strobe type 3Strobe type 4Strobe type 5Strobe type 6
12| PLATE Red| 0-255| PLATE red intensity 0-100%
13| PLATE Green| 0-255| PLATE green intensity 0-100%
14| PLATE Blue| 0-255| PLATE blue intensity 0-100%
| 15| FX CROSS| 0-255| Crossfade duration snap-slow
| 16| PLATE RGB Shape speed| 0-255| Slow-fast
| 17| PLATE RGB Shape selection| 01-56-1011-2021-3031-4041-5051-6061-7071-8081-9091-100101-110111-120121-130131-140141-150151-160161-170171-180181-190191-200201-210211-220221-230231-240241-250251-255| No shape Background color RGB fadeRGB chase Shape 1Shape 2Shape 3Shape 4Macro 1Macro 2Macro 3Macro 4Macro 5Macro 6Macro 7Macro 8Macro 9Macro 10Macro 11Macro 12Macro 13Macro 14Macro 15Macro 16Macro 17Macro 18Macro 19Macro 20
| 18| WHITE BEAM Shape speed| 0-255| Slow-fast
| 19| WHITE BEAM ShapeSelection| 0-255|
| 20| PLATE RGB Background Dimmer| 0-255| Background intensity 0-100%
| 21| | PLATE RGB BackgroundRed| 0-255| Background red intensity 0-100%
| 22| | PLATE RGB BackgroundGreen| 0-255| Background green intensity 0-100%
| 23| | PLATE RGB BackgroundBlue| 0-255| Background blue intensity 0-100%
| | 212223| PLATE PIXEL 1 Red PLATE PIXEL 1 Green PLATE PIXEL 1 Blue| 0-2550-2550-255| Control signle RGB PLATE PIXEL
| | 242526| PLATE PIXEL 2 Red PLATE PIXEL 2 Green PLATE PIXEL 2 Blue| 0-2550-2550-255
| | …| …|
| | 545556| PLATE PIXEL 12 Red PLATE PIXEL 12 Green PLATE PIXEL 12 Blue| 0-2550-2550-255
| | 57| WHITE BEAM 1| 0-255| Control single WHITE BEAM section

Menu access password : UP – DOWN – UP – DOWN – ENTER

1st LEVEL 2nd LEVEL 1rd LEVEL 1th LEVEL
DMX Address XXX (1-499) enter
Net IP IP Address IP (0-255) Enter
IP (0-255) Enter
IP (0-255) Enter
IP (0-255) Enter
Sub tmask 255.0.0.0 Enter
255.255.0.0 Enter
255.255.255.0 Enter
Set Universe Strobe Universe 0-32766 Enter
Aura Universe 0-32766 Enter
DMX channel mode 23 CH (DMX) enter
14 CH (DMX) enter
68 CH (DMX) enter
OFFline statu Hold enter
Manual enter
Auto enter
OFF enter
On enter
1rd LEVEL 1th LEVEL
0-255
Strobe 0-255
Macro 1 0-255
Macro S1 0-255
Macro 2 0-255
Macro S2 0-255
Macro Color 0-255
Char1 0-255
Char2 0-255
Char3 0-255
Char 4
Char 5
Char Color
BackColor Red
BackColor Green
BackColor Blue
White 1
White 2
White 3
White 4
White 5
White 6
White 7
White 8
1rd LEVEL 1th LEVEL
Speed RGB
Show W
Speed W
Char Color
Char 1
Char 2
Char 3
Char 4
Char 5
Chinese
English
Display Direct Normal
reverse
Backlight ON
30s
Yes
Yes
Channel
Ver
Time
Temperature

DRAWINGS

Dimensions in [mm]

Dimensions
Dimensions
Dimensions

FLASH-BUTRYM Sp.j.
Skarbimierzyce 18 · 72-002 Dołuje · POLAND
WWW.FLASH-BUTRYM.PL

FLASH Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FLASH User Manuals

Related Manuals