General Specification

  • Compatible Drives: ODE-2, ODE-3, ODP-2, ODL-2, ODV-3, CV
  • Signal Interface: Standard 8-way RJ45 connector
  • Supply Input: 24V + / – 10%, DC, 30mA
  • RS485 Signal: Industry standard 2-wire +5V differential
  • Environmental: Operational: -10 … 50°C
  • Storage: -40°C … 60°C
  • Relative Humidity: < 95% (non condensing)
  • Protection Rating: IP55
  • Max Cable Length: 25m / 82.5ft shielded twisted pair

Mechanical Installation

Dimensions

FIG 1 Dimensions.JPG

Through Panel Mount

The panel on to which the Optipad is to be mounted should be cut out in accordance with the diagram below.

Electrical Installation

Cable Requirements

FIG 3 Cable Requirements.JPG

CAUTION! Incorrect cable connection may damage the drive. Extra care should be taken when using third party cable.

Allowed System Configurations

FIG 4 Allowed System Configurations.JPG

Different drive models can be used on the same Optipad network provided a unique communications address is assigned to each.
NOTE Cannot be used with Master – Slave or Cascade Control

Keypad and Display Layout

The illustration below explains the main features of the Optipad. Please note that some features and display messages are specific to certain variants of the Optidrive family.

FIG 5 Keypad and Display Layout.JPG

Easy Startup

To setup the Optidrive communication address
By default, the Optipad will try to communicate with the drive that has Address 1 in the network after powering up for the first time.
The Optipad will display “Scanning for Drive 01.” after power up, which indicates that the Optipad is searching for the drive with the correct drive address in the network. Once the drive has been found, the message “Load…” will be displayed on the Optipad, which indicates that the Optipad is reading the configuration information from the drive. Usually it will take 1~2 seconds for the Optipad to read this information. After the data has been loaded, the Optipad will display the drive real time status.

NOTE In the case where the keypad is connected to a drive where the network address is not 1, the following steps can be used to set the address of the drive

Working with Multiple Drive Networks
When the Optipad is used on networks with multiple drives, the user can change the drive address to set up communication with another drive in the same drive network at anytime.

FIG 7 Working with Multiple Drive Networks.JPG

NOTE For detailed parameter listing and functional setup, please refer to the corresponding Optidrive user guide

Networks with 2 Optipads connected
A maximum of 2 Optipads can be connected within the same drive network to communicate with the same drive or different drives.
When using two Optipads simultaneously on a network, the user must change the Optipad Device Number on the second Optipad to ensure correct operation. All Optipad units are set to Device Number 1 by default.

FIG 8 Networks with 2 Optipads connected.JPG

NOTE Once the User has set the Optipad as Device Number 2, OptiTools software cannot be used on the same drive network.
The Optipad Device Address should only be changed to 2 if 2 Optipad units are connected on a network. An Optipad with Device Number 1 must always be present for the network to function correctly.

Changing the Display Language

FIG 9 Changing the Display Language.JPG

Operating Displays

FIG 10 Operating Displays.JPG

Additional Display Messages

FIG 11 Additional Display Messages.JPG

FIG 12 Additional Display Messages.JPG

Changing Parameters

FIG 13 Changing Parameters.JPG

Parameter Factory Reset / User Reset

FIG 14 Parameter Factory Reset User Reset.JPG

Drive Fault Messages and Trip Codes
See Optidrive User Guide for further information.

Further Status Messages and Troubleshooting

Optipad uses various display messages to indicate different working status. See the following table for more information.

Status Messages

FIG 15 Status Messages.JPG

Troubleshooting

FIG 16 Troubleshooting.JPG

Invertek Drives Ltd. Offa’s Dyke Business Park, Welshpool, Powys SY21 8JF United Kingdom
Tel: +44 (0)1938 556868 Fax: +44 (0)1938 556869
www.invertekdrives.com

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals