FLASH RGBWA+UV FLAT LED Par Light User Manual

June 12, 2024
FLASH

FLASH RGBWA+UV FLAT LED Par Light User Manual

<https://flash-butrym.pl/en_US/p/LED-PAR-64-18x12-RGBWA-UV-FLAT/754>

WARNING! Use clamp to rig the fixture.

WARNING! When clamping the fixture to a truss or other structure at any other angle than with the yoke hanging vertically downwards, use two clamps of half-coupler type. Do not use any type of clamp that does not completely encircle the structure when fastened.

WARNING! Position or shade the bar so that the front lens will not be exposed to sunlight or any other strong light source from any angle – even for a few seconds. See Figure 1. The LED PAR lens can focused the sun’s rays, creating a potential fire hazard and causing damage.

IMPORTANT! Do not point strong light output from other fixtures at the LED PAR, as intense illumination can damaged the display.

Figure 1.

INTRODUCTION

THANK YOU FOR PURCHASING LED PAR 64. FOR SAFETY REASONS AND TO ENSURE THE TROUBLE-FREE OPERATION, CAREFULLY READ THE INSTRUCTIONS.

SAFETY INFORMATION

  • Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruction booklet.

  • Unpack and check carefully there is no transportation damage before using the fixture.

  • Before operating, ensure that the voltage and frequency of power supply match the power requirements of the fixture.

  • It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.

  • Disconnect main power before servicing and maintenance.

  • Use safety chain when fixes this fixture. Don’t handle the fixture by taking its head only, but always by taking its base.

  • Maximum ambient temperature is: 40°C Don’t operate it where the temperature is higher than this.

  • In the event of serious operating problem, stop using the fixture immediately. Never try to repair the fixture by yourself.
    Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.

  • Do not connect the device to any dimmer pack.

  • Do not touch any wire during operation and there might be a hazard of electric shock.

  • To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture.

  • The housing must be replaced if they are visibly damaged.

  • Do not look directly at the light spot while the fixture is on.

PRODUCT INFORMATION

  • Light Source:
    18x12W RGBWA+UV LED’s

  • Power consumption: 120W

  • Power supply voltage:
    100-240V, 50/60Hz AC

  • LED macro colors

  • Operating modes: DMX512,
    Manual, Auto, Sound-controlled,
    Master/Slave, Sound active,

  • DMX channel mode
    6/10A/10B

  • IP Rating: IP20

  • Housing made: Aluminium

  • Cooling: Active

  • AC IN/OUT: PowerCon

  • 3-Pin XLR DMX Input/Output

  • Net Weight: 2.2 kg

  • Gross weight: 2.6 kg

  • Net Dimensions:
    H(20)xW(20)xD(8) cm

  • Pack Size:
    H(23)xW(26)xD(26) cm

INSTALATION

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it. The fixture may be installed in any orientation, but if installed horizontally with a downward beam-angle, water can potentially pool in the fan wells. Under normal operation the moisture will evaporate. However, in locations with high rainfall, you may wish to fabricate a rain shield above the fixture, or modify the position and orientation of the fixture to minimize pooling. Two quarter-turn brackets are supplied with the fixtre if it is to be flown above the ground. Rig the fixture to a support truss or structure using the supplied brackets and suitable clamps. Fasten a safety cable between the support structure and the attachment point on the fixture. The safety cable must be able to bear at least 10 times the weight of the fixture.

The package includes:

  1. LED PAR (1 pc)
  2. Power cable type powerCON (1 pc)
  3. User Manual (1 pc)
  4. Mounting bracket (1 pc)

CONNECTION

The device is equipped with the following interfaces:

  1. DMX (in/out): XLR 3(5)-pin socket
  2. Power (in/out): powerCON socket

The connection is performed using cable with XLR-female -> XLR-Male plugs.

CAUTION! At the last fixture, the DMX signal has to be terminated with a terminator. Solder a 120Ω resistor between signal (-) and signal (+) into a XLR plug and plug it in the DMX output of the last fixture.

Diagram of connection of devices by DMX cable.

IMPORTANT! The maximum number of devices connected in series via power cable is 10 pcs.

The connection is performed using power cable with powerCON connector (included). The device must be operated by qualified personnel.

CAUTION! In the case of cable damage do not attempt to repair. Replacement or repair can be made only on the manufacturer or by a person with appropriate permissions

Using lamp, the change rate of power voltage should be within ±10%, if the voltage is too high, it will shorten the light’s life; if it’s not enough, the lamp will be dark. Please restart it after turning off light for 20 minutes until full-cooling. Frequent switching will reduce the life span of lamps and bulbs; intermittent using will improve the life of bulbs and lamps.

Voltage Specification.

Control Menu

Manual Menu

DMX CHART

FLASH-BUTRYM Sp.j.
Skarbimierzyce 18 · 72-002 Dołuje · POLAND
WWW.FLASH-BUTRYM.PL

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FLASH User Manuals

Related Manuals