V-TAC 80133970 Mono Solar Panel Installation Guide
- June 12, 2024
- V TAC
Table of Contents
V-TAC 80133970 Mono Solar Panel
Product Information
The Mono Solar Panel is a high-quality product manufactured by V-TAC. It has a model number of VT-545 and a rated maximum power of 545W with a tolerance of 0-+3%. The voltage at Pmax is 41.93V, and the current at Pmax is 20A, with an open-circuit voltage of 1500VDC and short-circuit current of 25A. The panel has a nominal operating cell temperature of Class A and can operate in a range of temperatures. It has 144 half mono cells and is made of an Aluminum Alloy & Tempered Glass body type with dimensions of 2094x1038x35mm or 2279x1134x35mm.
The panel is IP68 rated and has a maximum system voltage of
1500VDC, with a maximum series fuse range of 10. The product comes with a
multi-language manual QR code that customers can scan to access the manual in
various languages. The product also has a warranty rating of a year.
Product Usage Instructions
Before installing the Mono Solar Panel, please ensure that you have read the installation manual carefully. The installation manual provides detailed instructions for the mechanical and electrical installation of the panel, which must be followed to ensure the panel’s proper functioning. It is important to note that the panel must be installed in compliance with IEC61215 and IEC61730 standards. The panel should be mounted in the manner specified by the mounting instructions provided in the manual.
When installing the panel on a roof, make sure to take into account the overall fire rating of the finished structure and overall maintenance requirements. It is recommended that you have the roofing PV system installed only after assessment by construction experts or engineers and with official analysis results for the entire structure.
For your safety, please do not work on the roof without safety protective measures, including fall protection, ladders or stairs, and personal protective articles. Do not install or handle the panel in unfavorable conditions, including strong wind or gusts, damp, or sandy roofs.
The product manual contains suggestions that improve the safety of panel installation, which are tested and proven by practices. Please provide the manual to PV system users for reference and advise them of safety, operation, and maintenance requirements and suggestions. Finally, it is important to note that failure to install the panel as per the requirements set forth in the manual will render the quality warranty provided for customers during sales invalid.
TECHNICAL DATA
INTRODUCTION & WARRANTY
Thank you for selecting and buying V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any another query, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at the best. The warranty is valid for 10 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. This product is warranted for manufacturing defects only.
WARNING
- Please make sure to turn off the power before starting the installation.
- Installation must be performed by a qualified electrician.
- The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced.
- If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
- Proper grounding should be ensured throughout the installation.
INTRODUCTION
This installation manual does not entail any explicit or implicit quality warranty and does not stipulate on compensation schemes for losses, module damages or other costs caused by or related to module installation, operation, utilization and maintenance process. If patent rights or the third party rights are infringed by use of modules, V-TAC will not take any responsibility. V-TAC reserves the rights for modifying product manual or installation manual without notice in advance.
If customers fail to install modules as per requirements set forth in this manual, the quality warranty provided for customers during sales will become invalid. In addition, suggestions in this manual are to improve safety of module installation, which are tested and proved by practices. Please provide this manual to PV system users for reference to and advise them of safety, operation and maintenance requirements and suggestions.
Laws and regulations
Mechanical and electrical installation of PV modules shall follow proper regulations such as electric law, building law and electric connecting requirements. These regulations differ with different installation sites, such as building roofing installation, vehicle-mounted application. Requirements may also differ with installation system voltage, DC or AC. See specific clauses in local authorities.
Module identification
Each module is pasted with 3 labels providing information below:
-
Nameplate: It describes product type, standard rated power, rated current, rated voltage, open circuit voltage, short circuit current under testing conditions, certification indicator, maximum system voltage, etc.
-
Current level label: Divide modules as per their optimal working current and there are values: H, M or L (H means the highest current level). The best practice is to install modules with the same current level (such as H) in one strand in the process of installation.
-
Serial No.: Each module has a unique serial number which is solidified inside the module permanently and it can be seen from front top of the module. Each serial number is put in before laminating of the module.
-
Aluminum alloy frame
-
PV tempered glass
-
Packaging EVA
-
Cells
-
Back plate
-
Silica gel
-
Connecting box
-
Nameplate
-
Cables
-
Connector
-
Mounting hole
-
Grounding hole
-
Leakage hole
-
Cell
Figure 1 Module Section Structure and Components
Regular safety
V-TAC module is considered to be in compliance with IEC61215 and IEC61730 only when the module is mount-ed in the manner specified by the mounting instructions below. When the module is installed on roof, it is necessary to take the overall fire rating of the finished structure as well as later overall maintenance into account. The roofing PV system shall be installed after assessment by construction experts or engineers and with official analysis results for the entire structure. It shall be proved capable of supporting extra system bracket pressure, including PV module weight. For your safety, please do not work on the roof without safety protective measures which include but not limited to fall protection, ladder or stair and personal protective articles. For your safety, please do not install or handle modules in unfavorable conditions including but not limited to strong wind or gust, damp or sandy roofs.
Electric performance safety
- PV products will produce DC in the sunlight, so there may be electric shock or burning when touching module connecting line metals. 30V DC voltage or higher voltage can be fatal.
- In case of no connected load or external circuits, modules can also produce voltage. Please use insulation tools and wear rubber gloves when operating modules in the sunlight.
- PV modules doe not have switch. PV modules can only stop work when they are kept from sunlight or covered by cloth, hard board or light-proof materials or when front side of modules are placed on smooth and flat surfaces.
- To avoid electric arc or electric shock hazards, please do not break down electric connection in loaded condi-tions. Wrong connections will also lead to electric arc or shock. Keep connectors dry and clean and make sure that they are in good working condition. Do not insert other metals into the connectors or carry out electric connection by whatever means.
- Snow and water in surrounding environments will intensify light reflection and lead to increase of current and output power. And module voltage and power will increase under low temperature.
- If module glass or packaging materials are damaged, please wear personal protective articles and isolate modules from the circuit.
- Working is only allowed in dry conditions by means of dry tools. Do not operate when modules are wet unless you wear the proper electric shock protection device. Please operate following the cleaning requirements in this manual when cleaning modules.
Operation safety
- Do not open V-TAC Package in transportation and storage process unless the modules arrive at the installation site.
- Do not damage the package and do not make packaged modules on pallet fall directly.
- Do not exceed the highest layer limit indicated on the packaging carton when piling modules up.
- Put packaging carton in the ventilated, rain-proof and dry places before unpacking of modules.
- Open V-TAC’s packaging carton following unpacking instructions.
- Do not hold the connecting box or wires to lift the entire module in any cases.
- Do not stand or walk on modules.
- Do not pile one module onto another.
- To avoid glass damage, do not put heavy objects on module glass.
- Be careful when placing modules on a surface and at corners in particular.
- Do not try to unpack the module or remove nameplate or parts of modules.
- Do not paint surface of modules or apply any other glues.
- Do not damage, grad or scratch back film of modules.
- Do not drill frame of modules, which may reduce frame loading capacity or lead to frame corrosion.
- Do not scratch anodic coating of aluminum alloy frame except for grounding connection.
- Scratch may lead to frame corrosion and reduce frame loading capacity.
- Do not repair glass or modules whose back film is damaged on your own.
Fire safety
- Please consult local laws and regulations before installing modules and abide by requirements on building fire protection. Fire rating of V-TAC modules is TypeC according to IEC61730.
- The roof shall be coated with a layer of fireproof materials of such rating for roofing installation and make sure that the back plate and the mounting surface are fully ventilated.
- Difference of roofing structures and installation modes will affect fireproof performance of buildings. Improper installation may lead to fire disasters.
- To guarantee roof fire rating, the module frame shall be at least 10cm from the roof surface.
- Adopt proper module accessories such as fuse, circuit breaker and grounding connector according to local regulations.
- The fire rating of this module is valid only when mounted in the manner specified in the mechanical mounting instructions.
- Please do not use modules if there are exposed inflammable gases nearby.
Installation conditions
- Installation site and working environments
- The modules can only be used on earth but not in outer space.
- Do not focalize sunlight with mirrors or magnifying glass artificially onto modules.
- V-TAC modules shall be installed on proper buildings or other appropriate places (such as ground, garage, building outer wall, roof, PV tracking system) but shall not be installed on any mobile vehicles.
- Do not install modules at such places as that are possible to be submersed. V-TAC suggests that modules be installed in the working environment with the temperature of -20 to 46 which is the monthly average highest and lowest temperature of the installation places. The extreme working environment temperature for modules is -40 to 85 .
- Make sure that installed modules do not suffer wind or snow pressure that exceeds the permissible maximum load.
- Modules shall be installed in places free from shades throughout the year. Make sure there are no light-blocking obstacles in the installation places.
- Carry out lightning protection for modules installed in places with frequent lightning and thunder.
- Do not install modules in places with possible inflammable gases.
- Modules can not be used in environments with too much hails, snows, flue gas, air pollution and soot or in places with strong corrosive substances such as salt, salt mist, saline, active chemical steam, acid rain, or other substances corroding modules, affecting module safety or performance.
- Please take protective measures to ensure reliable and safe installation of modules in severe environments such as heavy snow, cold and strong wind or islands close to water and salt mist or deserts.
Selection of tilt angles
- Tilt angle of modules: Included angle between module surface and horizontal surface; the module will obtain the maximum power output in direct facing of sunlight.
- Modules are preferred to be south-facing in the north hemisphere and north-facing in the south hemisphere.
- A specific installation angle shall be determined according to installation guide for standard modules or sugges-tions from PV module installer.
- V-TAC suggests that module installation tilt angle be no less than 10° so module surface dust can be washed away easily by rainfall and times of cleaning can be reduced. And it is easy for ponding to flow away and avoid water print on the glass due to long time of water ponding which may further affect module appearance and performance.
Mechanical installation
Regular requirements
Make sure that module installation mode and bracket system are solid enough to
bear the expected load, which is requisite assurance that the bracket
installer must provide. Installation bracket system shall be tested and
inspected by the third party testing institution with static mechanical
analysis capacity in accordance with local national or international
standards.
Module bracket shall be made from durable, corrosion resistant, ultraviolet
proof materials.
Modules shall be fixed on the bracket solidly.
Use higher brackets in places with heavy snow accumulation so the lowest point
of modules will not be covered by snow for a long time. In addition, make the
lowest point high enough so as to avoid sheltering of vegetations and woods or
damage of flying sands and stones.
If modules are installed on brackets parallel to the roof or wall, the minimum
gap between the module frame and the roof/wall shall be 10cm for air
ventilation so as to prevent module line damage.
Do not make holes on glass or frame of modules.
Make sure the building is suitable for installation before installing modules
on roof. Moreover, seal permeable parts properly to prevent leakage.
The module frame has thermal expansion and cold contraction so the frame
interval between two adjoining modules shall be less than 10mm.
Make sure that back plate of modules will not contact bracket into the module
or building structures, especially when the module surface is imposed by
pressure.
V-TAC Solar Modules have been certified for a maximum design static load on the
back of the
Modules of up to 1600Pa1.5 (i.e. wind load) and a maximum design static load
on the front of the
Modules of up to 3600Pa1.5 (i.e. wind and snow load), depending on the clamp
mounting (please refer to follow installing data for this information). And
this is printed on the label of modules.
Module installation methods can not lead to electrochemical corrosion between
module aluminum frame and different metals. Electrochemical potential difference
of contacting metals shall not exceed 0.6V as is recom-mended in IEC61730
Appendix Flat Plate Photovoltaic Modules and Panels.
Modules can be installed horizontally or vertically.
Way of installation
Module and bracket system connection can be realized by clamp or embedded
systems. Installation shall follow the demonstration and suggestions below. If
installation mode is different, please consult V-TAC and obtain approval.
Otherwise, modules may be damaged and quality warranty will become invalid.
Use clamps to install modules
Use the special clamp to install modules. See Figure 3.
- A. Fix modules on the bracket by metal clamp. The following clamps or those clamps recognized by module system installer are recommended.
- Width: no less than 40mm;
- Thickness: no less than 3mm;
- Material: aluminum alloy;
- Bolt: M6.
- B. Torque range for bolt fastening: 18N•m to 24N•m
- C. The clamp shall not contact glass or make module frame deformed in any case. The contactingsurface of the clamp and frame front side shall be neat and smooth. Otherwise, frame and module may be damaged. Make sure that the clamp will not produce shading effect. Drain holes can not be
sheltered by the clamp.
Position of installation connecting points
- Low/normal load working condition applies to most environments: the maximum static load for backside is 1600Pa1.5 (equal to wind pressure) and the maximum static pressure for the front side is 1600Pa1.5 (for 4 clamps installation) (equal to wind pressure and snow pressure).
- Higher load applies to severe environments (such as wind storm, heavy snow): the maximum static load for backside is 1600Pa1.5 (equal to wind pressure) and the maximum static pressure for the front side is 3600Pa1.5 (for 6 clamps installation) (equal to wind pressure and snow pressure).
Electric installation
Electric performance
Module electric performance parameters such as Isc, Voc and Pmax nominal
values have ±3% error with those under standard testing conditions of:
irradiance of 1000 W/m2, cell temperature of 25C and air mass of AM1.5. Under
normal conditions, a photovoltaic module is likely to experience conditions
that produce more current and/or voltage than reported at standard test
conditions. The requirements of the National Electrical Code (NEC) in Article
690 shall be followed to address these increased outputs. In installations not
under the requirements of the NEC, the values of Isc and Voc marked on this
module should be multiplied by a factor of 1.25 when determining component
voltage ratings, conductor ampacities, overcurrent device ratings, and size of
controls connected to the PV output.
When modules are in series connection, the final voltage is sum of that of the
single module. When modules are in parallel connection, the final current is
sum of the single module. See Figure 5
Modules with different electric performance models can not be connected in one
series.
The number of modules in series connection in each strand shall be calculated as per requirements. The open circuit voltage value under the expected lowest temperature shall not exceed the maximum system voltage value stipulated for modules (V-TAC module maximum system voltage is DC1500V according to IEC61730) and other values required by DC electric parts. Maximum series overcurrent protective device, where required.
If there is reverse current exceeding the maximum fuse current flowing through the module, use overcurrent protection device with the same specifications to protect the module; if parallel connection strands are more than 2, there shall be an overcurrent protection device on each strand of module. See Figure 5.
Cables and connecting lines
In module design, adopt enclosed connecting boxes with the protective level of
IP68 for onsite connection to provide environmental influence protection for
wires and connections and contacting protection for non-insulat-ing electric
parts. The connecting box has well connected cables and connectors with the
protective level of IP68. These designs facilitate parallel connection of
modules. Each module has two independent wires connect-ing the connecting box,
one is negative pole and the other is positive pole. Two modules can be in
parallel connection by inserting the positive pole at one end of wire of one
module into the negative pole of the adjoin-ing module.
Cables connecting modules shall satisfy the module maximum short circuit
current. Adopt the special PV system sunlight resistant cables.
The minimum standards of cables connecting modules are:
When cables are fixed on the bracket, avoid mechanical damage to cables or modules. Do not press cables by force. Adopt special designed light resistant wires and clamps to fix cables on the bracket. Though cables are light resistant and water proof, it is still necessary to prevent cables from direct sun radiation and water immer-sion.
Connector
Please keep connectors clean and dry. Make sure connector nuts are fastened
before connection. Do not connect connectors that are damp or dirty or under
other status. Protect connectors from direct sun radiation and water immersion
or fall onto ground or roof. Wrong connection may lead to electric arc and
electric shock. Please make sure that all electric connection is reliable.
Make sure all connectors with lock are fully locked.
Bypass diode
V-TAC solar module connecting box contains bypass diode which is in parallel
connection with the cell strands. If heat spot occurs locally with the module,
the diode will come into operation to stop the main current from flowing
through the heat spot cells with the view to restrain module heating and
performance loss. But bypass diode is not the overcurrent protection device.
If the diode is found or doubted to get out of order, the installer or system
maintenance supplier shall contact V-TAC. Please do not try to open the module
connecting box on your own.
Grounding
In design of modules, the anodized corrosion resistant aluminum alloy frame is
used for rigidity support. For safety utilization and to protect modules from
lightning and static-electricity damage, the module frame shall be grounded.
The grounding device shall be in full contact with inner side of the aluminum
alloy and penetrate the frame surface oxide film.
Do not drill additional grounding holes on module frame.
To get the optimal power output, V-TAC suggests that DC negative pole of the
module array shall be grounded in installation of modules. Otherwise, the
system power output will be reduced.
Module installation methods can not lead to electrochemical corrosion between
module aluminum frame and different metals. Electrochemical potential difference
of contacting metals shall not exceed 0.6V as is recom-mended in IEC61730
Appendix Flat Plate Photovoltaic Modules and Panels.
Holes on the frame shall be drilled in advance and grounding signs shall be
indicated. These holes are only used for grounding but not for installation of
modules.
A module with exposed conductive parts is considered to be in compliance with
IEC61730 only when it is electrically grounded in accordance with the
instructions presented below and the requirements of the National Electrical
Code.
Where common grounding hardware (nuts, bolts, star washers, spilt-ring lock
washers, flat washers and the like) is used to attach a listed
grounding/bonding device, the attachment must be made in conformance with the
grounding device manufacturer’s instructions.
V-TAC recommends must thoroughly detail the attachment means in the module
installation instructions. Common hardware items such as nuts, bolts, star
washers, lock washers and the like have not been evaluated for electrical
conductivity or for use as grounding devices and should be used only for
maintaining mechanical connections and holding electrical grounding devices in
the proper position for electrical conductivity. Such devices, where supplied
with the module and evaluated through the requirements in IEC61730, may be
used for grounding connections in accordance with the instructions provided
with the module.
Grounding methods below are permissible:
Grounding by grounding clamp
There is a grounding hole with the diameter of Ø4.2mm at the edge of the
module back frame. The central line of the grounding sign and that of the hole
overlaps and is consistent with the frame length direction.
Grounding between modules shall be confirmed by qualified electricians and
grounding devices shall be manu-factured by qualified electric manufacturer.
The torque is recommended to be 2.3N•m. 12 AWG copper core wire is used for
the grounding clamp. And copper wires can not be pressed damaged in
installation.
Grounding by unoccupied mounting holes
Mounting holes on modules that are not occupied can be used for installing grounding devices.
- Align grounding clamp to the frame mounting hole. Use grounding bolt to go through the grounding clamp and frame.
- Put the tooth side of the washer on the other side and fasten the nuts. The recommended torque for nut fastening is 2.0Nm to 2.2Nm.
- Put grounding lines through the grounding clamp and grounding wire material and dimension shall meet requirements in local national and regional law and regulations.
- Fasten bolts of grounding lines and installation ends.
Figure 7 Way of Installation
The third party grounding devices
The third party grounding device can be used for grounding of V-TAC modules but such grounding shall be proved to be reliable. Grounding device shall be operated in line with stipulations of the manufacturer.
Operation and maintenance
Carry out regular inspection and maintenance for modules and this is the user’
responsibility within the quality warranty period in particular; and, inform
the supplier within two weeks when modules are found to be damaged.
Cleaning
Accumulated dust on module surface glass will reduce the power output and lead
to local heat
spot, such as industrial waste water and birds droppings. The degree of
influence is determined by transparency of wastes. Small amounts of dust will
affect sunlight strength and evenness but are not dangerous and power will not
be reduced remarkably in general.
During operation of modules, there shall be no environmental factors
projecting shades or shelter
partial or the entire module, including other modules, module system bracket,
birds, dust, soil or
plants. These will reduce output power. V-TAC suggests that the module surface
should not be sheltered in any case.
Frequency of cleaning depends on dirt accumulation speed. In normal
situations, rainwater will clean the module surface and the cleaning frequency
is reduced therefore. It is suggested to use damp clean water sponge or soft
cloth to wipe the glass surface. Do not use acid and alkaline detergents to
clean modules.
Module appearance inspection
Check module appearance defects visually, especially:
- Module glass cracks.
- Corrosion at welding parts of the cell main grid: it is caused by moisture into the module due to damage of surface packaging materials during installation or transportation.
- Check whether there is burning traces on the module back plate.
Inspection of connectors and cables
It is suggested to carry out a preventive inspection once every 6 month:
- Check connector sealing and cable connection solidness.
- Check whether sealant of the terminal box is cracking with gap.
IN CASE OF ANY QUERY/ISSUE WITH THE PRODUCT, PLEASE REACH OUT TO US AT: SUPPORT@V-TAC.EU FOR MORE PRODUCTS RANGE, INQUIRY PLEASE CONTACT OUR DISTRIBUTOR OR NEAREST DEALERS. V-TAC EUROPE LTD. BULGARIA, PLOVDIV 4000, BUL.L.KARAVELOW 9B
MULTI-LANGUAGE MANUAL QR CODE
Please scan the QR code to access the manual in multiple languages.
This marking indicates that this product should not be disposed of with other
household wastes.
Caution, risk of electric shock.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>