SPENCER VCIMD-14918 Uniflex Pipe Coupling Installation Guide

October 30, 2023
SPENCER

VCIMD-14918 Uniflex Pipe Coupling
Installation Guide

WARNING
CALIFORNIA PROPOSITION 65
This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Introduction

This installation sheet covers the installation of the Uniflex Coupling.

Product Description

The Uniflex Coupling is a modified forged steel or stainless steel pipe union utilizing a spiral wound gasket to provide a leak tight joint. Use of the Uniflex in all regulator and trap stations through 2 in. / 50.8 mm to simplify future change outs. The Uniflex Coupling is a straight through design that consists of a spiral wound gasket, an inlet housing, an outlet housing and the housing nut, see Figure 1.

SPENCER VCIMD 14918 Uniflex Pipe Coupling - Uniflex Union
Assembly

Specifications

Available Models
SUA-T: Threaded Carbon Steel
SUA-SW: Socket weld Carbon Steel
SUASS-T: Threaded Stainless Steel
SUASS-SW: Socketed Stainless Steel
Maximum Temperature 850°F/454°C
Maximum Pressure 3000 psig/207 bar

Installation

WARNING
Personal injury, property damage, equipment damage or leakage due to escaping steam or bursting of pressure containing parts may result if this equipment is over pressured or is installed where service conditions could exceed the limits given in the specifications or where conditions exceed any ratings of the adjacent piping or piping connections. To avoid such injury or damage, provide pressure-relieving or pressure-limiting devices (as required by the appropriate code, regulation or standard) to prevent service conditions from exceeding those limits.
Threaded Union Installation
The installation procedure for the Uniflex Coupling is similar to the installation procedure for any standard pipe union, with the following exceptions:

  1. Care must be taken in positioning the spiral-wound gasket without a retainer.
  2. Apply a thin film of silicone grease or thread lubricant in the groove of the inlet housing before inserting the gasket. Gaskets with a retainer do not require this step.
  3. Apply thread lubricant to the external threads of the union to have proper sealing force.
  4. Properly tighten the union to ensure leak-proof seal.
  5. Retighten the union after it reaches full temperature.

Socket Weld Unions Installation
Whenever welding is performed adjacent to the Uniflex Couplings, the following steps must be taken to avoid destruction of the gasket by heat and/or arcing of the Union surfaces.

  1. Remove gasket from the Uniflex Coupling.
  2. Wrench-tighten the Uniflex Coupling after gasket has been removed.
  3. Place grounding clamp as close as possible to the point of the weld.
  4. Allow the Uniflex Coupling to cool before installing the gasket.
  5. Always use new gasket when the Uniflex Coupling is disassembled.

Replacement Parts

Type SUG or SUGR (with retainer) replacement parts kit are available from the factory. Type SUG kit includes (10) Uniflex replacement gaskets. Type SUGR kit includes (10) Uniflex replacement gaskets and (10) retaining devices.
**SpenceValve.com
Emerson Automation Solutions**

Americas
McKinney, Texas 75070 USAT +1 800 558 5853
+1 972 548 3574| Asia Pacific
Singapore 128461, Singapore
T +65 6777 8211
---|---
Europe
Bologna 40013, Italy
T +39 051 419 0611| Middle East and Africa
Dubai, United Arab Emirates
T +971 4 811 8100

VCIMD-14918 © 2020, 2021 Emerson Electric Co. All rights reserved 01/22. Spence is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are property of their prospective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Emerson Electric Co. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Electric Co. product remains solely with the purchaser.

www.SpenceValve.com
0011129

Documents / Resources

| SPENCER VCIMD-14918 Uniflex Pipe Coupling [pdf] Installation Guide
SUA-T, SUA-SW, SUASS-T, SUASS-SW, VCIMD-14918 Uniflex Coupling, VCIMD-14918, VCIMD-14918 Coupling, Uniflex Coupling, Coupling, VCIMD-14918 Uniflex Pipe Coupling, Uniflex Pipe Coupling, Pipe Coupling
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals