Installation Instructions for
GENERATION LIGHTING
Rocha Wall
OUTDOOR
ENERAL RODUCT NFORMATION
These fixtures are intended to be installed utilizing NEC compliant junction
boxes.
This product is safety listed for wet locations.
This instruction shows a typical installation.
CAUTION RISK OF FIRE
This product must be installed in accordance with the applicable installation
code by a person familiar with the construction and operation of the product
and the hazards involved. Use minimum 90°c supply conductors.
SAVE THESE INSTRUCTIONS!
Install the Fixture
- Temporarily install the mounting plate to the junction box and mark the anchor locations through the holes on the mounting plate. Remove the mounting plate.
- Drill appropriate sized holes at the marked locations and install the anchors.
- Secure the mounting plate to the junction box and screw the anchor screws into the anchors.
- Connect the fixture to a suitable ground in accordance to local electrical codes.
- Connect the white fixture wire (square and/or rigid) to the neutral power line wire with a wire nut.
- Connect the black fixture wire (round and/or smooth) to the hot power line wire with a wire nut.
- Neatly place all the wires into the junction box, place the fixture base onto the mounting plate, and secure it in place with the fixture screws.
- Caulk around the base of the fixture with waterproof construction sealant.