ThermoTec Inverpro Pool Pump Instruction Manual
- June 3, 2024
- ThermoTec
Table of Contents
ThermoTec Inverpro Pool Pump
IMPORTANT SAFETY INSTRUCTIONS
This guide provides installation and operation instructions for this pump. If you have any other questions about this equipment, please consult your supplier.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
- RISK OF ELECTRICAL SHOCK. Connect only to a branch circuit protected by a ground-fault circuit interrupter (GFCI). Contact a professionally trained and qualified electrician if you cannot verify that the circuit is protected by a GFCI.
- This pump is for use with permanently installed in-ground or above-ground swimming pools and may also be used with hot tubs and spas with a water temperature under 50℃. Due to the fixed installation method, this pump is not suggested to be used on above-ground pools that can be readily disassembled for storage.
- The pump is not submersible.
- Never open the inside of the drive motor enclosure.
All installations must be fitted with earth leakage or residual current protection devices, having a rated residual operating current not exceeding 30mA.
WARNING
- Fill the pump with water before starting. Do not run the pump dry. In case of a dry run, the mechanical seal will be damaged and the pump will start leaking.
- Before servicing the pump, switch the OFF power to the pump by disconnecting the main circuit to the pump and releasing all pressure from the pump and piping system.
- Never tighten or loosen screws while the pump is operating.
- Ensure that the inlet and outlet of the pump are unblocked with foreign matter.
TECHNICAL SPECIFICATIONS
Model| Advised Pool Volume
(m³)
| P1| Voltage (V/Hz)| Qmax (m³/h)| Hmax (m)|
Circulation (m³/h)
---|---|---|---|---|---|---
KW| At 8m| At 10m
IV18| 25~48| 0.08~0.75| 220~240/
50/60
| 21.8| 11.8| 5.4~18.0| 3.9~13.0
IV23| 30~65| 0.09~1.05| 24.0| 13.6| 6.7~22.3| 5.8~19.3
IV30| 45~75| 0.10~1.40| 28.8| 17.0| 8.6~28.8| 7.6~25.5
OVERALL DIMENSION (mm)
INSTALLATION
Pump Location
- Install the pump as close to the pool as possible, to reduce friction loss and improve efficiency, use short, direct suction and return piping.
- To avoid direct sunshine, heat or rain, it is recommended to place the pump indoors or in the shade.
- DO NOT install the pump in a damp or non-ventilated location. Keep the pump and motor at least 150mm away from obstacles, pump motors require free circulation of air for cooling.
- The pump should be installed horizontally and fixed in the hole on the support with screws to prevent unnecessary noise and vibration.
Piping
- For optimization of the pool plumbing, it is recommended to use a pipe with a size of 63mm. When installing the inlet and outlet fittings (joints), use the special sealant for PVC material.
- The dimension of the suction line should be the same or larger than the inlet line diameter, to avoid the pump sucking air, which will affect the efficiency of the pump.
- Plumbing on the suction side of the pump should be as short as possible.
- For most installations, we recommend installing a valve on both the pump suction and return lines, which is more convenient for routine maintenance. However, we also recommend that a valve, elbow, or tee installed on the suction line should be no closer to the front of the pump than seven times the suction line diameter.
- The pump outlet piping system should be equipped with a check valve to prevent the pump from the impact of medium recirculation and pump-stopping water hammer.
Valves and Fittings
-
Elbows should be no closer than 350mm to the inlet. Do not install 90° elbows directly into the pump inlet/outlet. Joints must be tight.
The pump inlet/outlet union size: optional with metric (50 or 63mm) or imperial (1.5” or 2”) -
Flooded suction systems should have gate valves installed on the suction and return line for maintenance; however, the suction gate valve should be no closer than seven times the suction pipe diameter as described in this section.
-
Use a check valve in the return line where there is a significant height between the return line and the outlet of the pump.
-
Be sure to install a check valve when plumbing in parallel with other pumps. This helps prevent reverse rotation of the impeller and motor.
Check before the initial startup
- Check whether the pump shaft rotates freely;
- Check whether the power supply voltage and frequency conform to the nameplate;
- Facing the fan blade, the direction of motor rotation should be clockwise;
- It is forbidden to run the pump without water.
Application conditions
Ambient temperature | Indoor installation, temperature range: -10~42℃ |
---|---|
Water temperature | 5℃~50℃ |
Salt pools | Salt concentration up to 0.5%, i.e 5g/l |
Humidity | ≤90% RH, (20℃±2℃) |
Altitude | Not exceed 1000m above sea level |
Installation | The pump can be installed max. 2m above water level |
Insulation | Class F, IP55 |
SETTING AND OPERATION
Display on the control panel
Startup
When the power is switched on, the screen will be fully lit for 5 seconds, the device code will be displayed, and then it will enter the normal working state. When the screen is locked, only the button is lit; Press and hold for more than 3 seconds to unlock, and other buttons will all light up. The screen will automatically lock up when there is no operation for more than 1 minute and the brightness of the screen is reduced by 1/3 of the normal display. Short press to wake up the screen and observe the relevant operating parameters.
Self-priming
When switched on for the first time after installation, the pump will start
self-priming automatically。
The system performs the self-priming in Boost mode, it will count down from
the 1500s and stop automatically when the system detects the pump is full of
water, then the system will recheck for 60s again to make sure the self-
priming is completed. When completed, the pump will run at 80%
Remark:
The pump is delivered with self-priming enabled. Each time the pump restarts,
it will perform self-priming automatically. The user can enter the parameter
setting to disable the default self-priming function (see 5.8)
If the default self-priming function is disabled, and the pump has not been
used for a long time, the water level in the basket may drop, the user could
manually activate the Boost mode of priming to fill it (see 5.8), and the
adjustable period is from 600s to 1500s (default value is 600s).
The user could press for more than 3 seconds to exit the Boost mode.
Backwash
Users can start the backwash or fast re-circulation in any running state by pressing
| Default| Setting range
---|---|---
Time| 180s| Press or adjust from 0 to 1500s with 30 seconds for each step
Running capacity| 100%| 80~100%, enter the parameter setting (see 5.8)
If the backwash is completed or disabled, press and hold for 3 seconds, the pump will return to the normal operating state before backwash.
Setting the running capacity
1 | Press for more than 3 seconds to unlock the screen, and press to start | |
---|---|---|
2 | Press or set the running capacity between 30%~100%, each step by 5% |
Timer mode
When the pump is running, the timer can be set as needed.
1 | Enter the timer setting by pressing |
---|---|
2 | Press or to set the local time |
3 | Press to confirm and move to the time-1 setting |
4 | Press or choose the desired running periods and specific capacity or flow |
5 | Repeat the above steps to set the other 3 timers |
6 | Hold 3 seconds to save the setting |
7 | or Check 4 timers to make sure there is no invalid setting |
Note: The overlap setting of time will be considered as invalid, the pump will only run based on the previous valid setting.
During the timer setting, if you want to return to the previous setting, hold both for 3 seconds.
Parameter Setting
Restore factory setting | Under off mode, hold both for 3 seconds |
---|---|
Check the software version | Under off mode, hold both for 3 seconds |
Boost mode of priming | Under one mode hold both for 3 seconds |
Enter the parameter setting below | **** Under off mode, hold both for 3 |
seconds; If the current address does not need to be adjusted, hold both to
next address
Parameter
Address
| Description| Default Setting| Setting Range
---|---|---|---
1| PIN3| 100%| 30~100%, by 5% increments
---|---|---|---
2| PIN2| 80%| 30~100%, by 5% increments
3| PIN1| 40%| 30~100%, by 5% increments
4| Backwash
capacity
| 100%| 80~100%, by 5% increments
5| Control mode of
Analog Input
| 0| 0: current control
1: Voltage control
6
| Enable or disable the priming that occurs at each
start
| ****
25
| ****
25:enables
0: disables
WIFI OPERATION
InverFlow Download
Android
iOS
InverFlow Download
Register by e-mail or third-party application
Email Registration
Third-party application registration
Create Home
Please set the home name and choose the location of the device. (It is recommended to set the location so the weather can be shown in the App for your convenience)
App pairing
Please make sure your pump is turned on and running before you start.
Option 1 (Recommended): With Wifi and Bluetooth
(Network requirement: 2.4GHz; 2.4Ghz and 5GHz into one SSID; but no seperate 5GHz network)
- Please confirm that your phone is connected to Wifi and that your Bluetooth is on.
- Press for 3 seconds until hearing “Beep” to unlock the screen. Press for 5 seconds until hearing “Beep” then release. Will flash
- Click “Add Device” , and then follow the instructions to pair the device.
Option 2: With Wifi (Network requirement: 2.4GHz only)
- Please confirm that your phone is connected to Wifi
- Press for 3 seconds until hearing “Beep” to unlock the screen. Press for 5 seconds until hearing “Beep” then release. Will flash.
- Click “Add Device” , and then follow the instructions to pair the device.
Operation
- Using Manual Inverter Mode
Sharing Devices with your family members
After pairing, if your family members also want to control the device, please let your family members register “InverFlow” first, and then the administrator can operate as below:
Feedback
If you have any problem while using it, welcome to send feedback.
Notice:
- The weather forecast is just for reference;
- The power consumption data is for reference only, as it may be affected by network problems and imprecision of the calculation.
- The app is subject to updates without notice.
PROTECTION AND FAILURE
High-Temperature Warning and Speed Reduction
In “Auto-Inverter/Manual-Inverter Mode” and “Timer mode” (except backwash
/self-priming), when the module temperature reaches the high-temperature
warning trigger threshold (81℃), it enters the high-temperature warning state;
when the temperature drops to the high-temperature warning release threshold
(78℃), the high-temperature warning state is released. The display area
alternately displays AL01 and running speed or flow
If AL01 is displayed for the first time, the running capacity will be
automatically reduced as below:
- If current operating capacity is higher than 85%, the running capacity will be automatically reduced by 15%;
- If current operating capacity is higher than 70%, the running capacity will be automatically reduced by 10%;
- If current operating capacity is lower than 70%, the running capacity will be automatically reduced by 5%.
Suggestion for non-first displayed of AL01: check the module temperature every 2 minutes. Compared with the temperature in the previous period, for every 1-degree Celsius increase, the speed will decrease by 5%.
Undervoltage protection
When the device detects that the input voltage is less than 200V, the device
will limit the current running speed
When the input voltage is less than or equal to 180V, the running capacity
will be limited to 70%; When the input voltage range is within 180V~190V,
the running capacity will be limited to 75%;
When the input voltage range is within 190V~200V, the running capacity will be
limited to 85%.
Troubleshooting
Problem | Possible causes and solution |
---|---|
The pump does not start | • Power Supply fault, disconnected or |
defective wiring.
• Fuses blew or thermal overload open.
• Check the rotation of the motor shaft for free movement and lack of obstruction.
• Because of a long time lying idle. Unplug the power supply and manually rotate motor rear shaft a few times with a screwdriver.
The pump does not prime| • Empty pump/strainer housing. Make sure the pump/strainer housing is filled with water and the O ring of cover is clean.
• Loose connections on the suction side.
• Strainer basket or skimmer basket loaded with debris.
• Suction side clogged.
• Distance between the pump inlet and the water level is higher than 2m, the installation height of the pump should be lowered.
Low Water Flow| • Pump does not prime.
• Air entering suction piping.
• Basket full of debris.
• Inadequate water level in the pool.
---|---
Pump being noisy| • Air leak in suction piping, cavitation caused
by restricted or undersized suction line or leak at any joint, low water level
in the pool, and unrestricted discharge return lines.
• Vibration caused by improper installation, etc.
• Damaged motor bearing or impeller (need to contact the supplier for repair).
Error code
When the device detects a failure (except for the running capacity reduction strategy and 485 communication failure), it will power off automatically and display the failure code. After powering off for 15 seconds, check if the failure is cleared, if cleared, it will resume starting.
Item | Error Code | Description |
---|---|---|
1 | E001 | Abnormal input voltage |
2 | E002 | Output over-current |
3 | E101 | Heat sink overheat |
4 | E102 | Heat sink sensor error |
5 | E103 | Master driver board error |
6 | E104 | Phase-deficient protection |
7 | E105 | AC current sampling circuit failure |
8 | E106 | DC abnormal voltage |
9 | E107 | PFC protection |
10 | E108 | Motor power overload |
11 | E201 | Circuit board error |
12 | E203 | RTC time reading error |
13 | E204 | Display Board EEPROM reading failure |
14 | E205 | Communication Error |
15 | E207 | No water protection |
16 | E209 | Loss of prime |
Note:
When causes for E002/E101/E103 is displayed, the device will resume working
automatically, however when it appears a fourth time, the device will stop
working, to resume operation, unplug the device and plug in & restart again.
MAINTENANCE
Empty the strainer basket frequently. The basket should be inspected through the transparent lid and emptied when there is an evident stack of rubbish inside. The following instructions should be followed:
-
Disconnected the power supply.
-
Unscrew the strainer basket lid anti-clockwise and remove.
-
Lift up the strainer basket.
-
Empty the trapped refuse from the basket, rinse out the debris if necessary.
Note: Do not knock the plastic basket on a hard surface as it will cause damage -
Inspect the basket for signs of damage, and replace it.
-
Check the lid O-ring for stretching, tears, cracks, or any other damage
-
Replace the lid, hand tightening is sufficient.
Note: Periodically inspecting and cleaning the strainer basket will help prolong its life.
WARRANTY& EXCLUSIONS
Should a defect become evident during the term of the warranty, at its option, the manufacturer will repair or replace such item or part at its own cost and expense. Customers need to follow the warranty claim procedure in order to obtain the benefit of this warranty. The guarantee will be void in cases of improper installation, improper operation, inappropriate use, tampering or using non-original spare parts.
DISPOSAL
When disposing of the product, please sort the waste products as electrical or electronic product waste or hand it over to the local waste collection system. The separate collection and recycling of waste equipment at the time of disposal will help ensure that it is recycled in a manner that protects human health and the environment. Contact your local authority for information on where you can drop off your water pump for recycling
- THANK YOU FOR PURCHASING OUR INVERTER POOL PUMPS.
- THIS MANUAL CONTAINS IMPORTANT INFORMATION THAT WILL HELP YOU IN OPERATING AND MAINTAINING THIS PRODUCT.
- PLEASE READ THE MANUAL CAREFULLY BEFORE INSTALLATION & OPERATION AND RETAIN IT FOR FUTURE REFERENCE.
Read User Manual Online (PDF format)