ANTOP AP-L1 Intelligent Air Purifier User Manual
- June 12, 2024
- ANTOP
Table of Contents
ANTOP Intelligent Air Purifier
AP-L1 User
Manual
Product information
This product is an indoor air purifier, with the functions of smoke removal, dust removal, deodorization, formaldehyde removal and sterilization.
Product installation
Put on the right place
When using, the air inlet should keep o certain distance from walls and other
shielding objects.
(refer to the picture below for details) Connect the power supply
Connect the power cable to the power port at the bottom of the air purifier
Product Operation
Display and operation instructions
When the buttons are blinking, that function is turned off.
If the buttons are on for long time, that function is turned on.
Purification principle
Purification and sterilization:
- Purification: HEPA filter stops PM2.5 in the air The formaldehyde is chemically decomposed by activated manganese filter, and finally water and carbon dioxide are generated.
- Sterilization.
Light reacts with nano-photocatalytic materials in the filter to sterilize bacteria and decompose odors and harmful gases (TVOC) in the air.
Principle:
Maintenance
Be sure to turn and power off the purifier before performing the following operations
Caution
Carry
When moving, make sure to stop the host and pull out the power cord plug
Installment
- If the bottom cover is not installed correctly, the air purifier cannot start
- The air inlet should be more than 20cm away from the wall and other shielding objects,
Cleaning
- Cleaning dust on the HEPA filter is conducive to reducing the breeding of bacteria.
- Cleaning up the dust blocking the air inlet hole is conducive to prevent the decrease of air inlet volume.
- When not in use for o long time, please cover the air outlet to prevent dust falling into the top grille and internal fan blade surface.
Power supply
Use power cords and sockets according to the following instructions to avoid
fire, electric shock or damage:
- Do to excessively pull, twist, or bend the power cable. Otherwise, the core of the cable may be exposed or broken.
- It must be connected to a power socket that fits the power cord plug.
- Please don’t use power adapter of other brands.
- Be sure to disconnect the power supply before performing maintenance operations or moving the air purifier.
- If the supply cord is damaged, it must be replaced with one purchased from its manufacturer or service department.
Use
- If the product has abnormal sound, peculiar smell, high temperature, or irregular fan rotation, stop using it immediately.
- Do not put fingers or foreign objects in the air infit and outlet.
- Do to put hair, fabric, etc. close to the item, so as not to be involved in or block the air inlet and outlet.
- Do not sit, lean or tilt the host.
- Do not pour liquid or throw powder and fine matter into the machine from the air outlet.
Usage limits
Do not use it under the following conditions, otherwise electric shock, fire
and other damage may occur:
The air inlet hole must be far away from the open flame appliance please avoid
combustible materials into the item.
The air purifier must be far away from high temperature and heating
appliances.
- Easy to dump and other unstable places.
- Places with high temperature, humidity and water contamination, such as bathrooms.
- This product is not recommended for use by users with insufficient mental capacity or knowledge, including children, except under the supervision or guidance of a person responsible for their safety.
Name | Intelligent air purifier | Voltage | DC 24V | PM2.5 CADR | 225m3/h |
---|---|---|---|---|---|
Model | AP-• i | Rated power | 30W | PM CCM | P4 |
Size | 02. Omm*•••• mm | Noise | 33.1dB(A)⁓ 55.6dB(A) | Formaldehyde CADR |
142.4m3Vh
Net| ••••kg| area of HEPA filter| t⁓2.5n4| Formaldehyde CCM| F4
App area| ••••• m2| Formaldehyde removal efficiency| High| PM2.5 removal
efficiency| High
Parts| Harmful substances
---|---
Pb| Hg| Cd| Cr(VI)| Br| As| PBB| PBDE
Plastic shell| | | | | | | |
Fan| | | | | | | |
PCB| | | | | | | |
Power adapter| | | | | | | |
NEPA filter| | | | | | | |
The composite
filter| | | | | | | |
:The component does not contain the substance or cannot be detected by the
instrument
:The component contains the substance but the content is below the limit
specified in GB/T 26572
:The component contains the substance and the content exceeds the limit
requirements specified in GB/T 26572
The above test results are from ANTOP Laboratories
Warranty card
Thank you for buying our products
In order for you to use this product safely and satisfactorily, please read
the instructions carefully before use
Warranty Record:
User name…………………….
Model ……………….
Product ID …………………
Purchasing date…………………..(mm dd, yyyy)
Date | Maintenance | Maintenance man | Remark |
---|
Whole unit
- air purifier x
- Manual x 1
- Power adapter x 1
- Product warranty card x
- The composite filter x 1
Guarantee clause
Within three months from the date of the goods sold, if performance failure
occurs, it can be replaced with the new one with the intact item and gift box
(subject to inspection) excluding man-made damage.
Al artificial damage, self-dismantling, unsealing, improper use of al external
damage, not within the scope of the warranty.
If the card is required for warranty, the company has the right to provide
non-warranty treatment for failure to provide the card or unauthorized
alteration of the card.
Warranty for one year from the dote of sale, lifetime maintenance, accessories
are not within the scope of warranty.
Valid only under normally use.
Read User Manual Online (PDF format)