LIMITED WARRANTY

HAWS warrants that all of its products are guaranteed against defective material or poor workmanship for a period of one year from the date of shipment. The foregoing notwithstanding, HAWS warrants certain specific products or components thereof for an adjusted period. A list of these excepted products and components and a description of their respective warranty terms may be found here:
www.hawsco.com/warranty. HAWS’ liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first-class workmanship, provided that a claim is made in writing to Company within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS shall not be liable for the cost of repairs, alterations, or replacements, or the labor required to implement them, or for any expense connected therewith made by the owner or owner’s agents, except upon written authority from HAWS. HAWS shall not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that HAWS has made no other warranties either express or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, incidental, or consequential damages claimed to arise under the contract of sale.
Equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. Any HAWS emergency equipment is intended to supplement first-aid treatment. Due to widely varying conditions, HAWS cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries.
EXCEPT AS EXPRESSLY STATED HEREIN, HAWS HEREBY DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, ARISING BY LAW OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY MAY NOT BE MODIFIED OR EXTENDED WITHOUT THE WRITTEN CONSENT OF HAWS. REMEDIES AND REPLACEMENTS STATED HEREIN ARE EXCLUSIVE. IN NO EVENT SHALL HAWS BE LIABLE FOR ANY SPECIAL, PUNITIVE, CONSEQUENTIAL, OR INCIDENTAL DAMAGES TO ANY PERSON INCLUDING BUT NOT LIMITED TO DAMAGES FOR LOSS OF USE OR PROFITS, SUBSTITUTE PRODUCTS  OR COSTS, PROPERTY DAMAGE, OR OTHER MONETARY LOSS.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL, PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
FOR CUSTOMER SERVICE: 1-888-640-4297

RECOMMENDED TOOLS:
– Measuring Tape
– PVC Pipe Cutter
– Plastic Tubing Cutter
– PVC Solvent Weld Glue
– ¼” Bit-Holding Screwdriver
– Level
– 10” Pipe Wrench
– Adjustable Plier
– 1/8 and 5/32 Tamper Resistant Hex Bits (Supplied)
– 9/16” and 5/8” Box/Open Combination Wrenches, 8” Max Length
– 3/8” Socket Wrench/Rachet, 8” Max Length
– 9/16” Deep Socket
– 15/16” Socket

LOCATION OF UNIT: The Model 3611FR Bottle Filler / Fountain can be installed and assembled to be ADA accessible by first locating the pedestal base with at least 8 inches of clear unobstructed hardscape behind the pedestal. Provide a hardscape that is at least 74 inches wide. When the right pedestal arm is installed in the high orientation, the height dimensions shown on the model specification sheet meet current Federal Americans with Disabilities Act (ADA) wheelchair requirements. The bottle filler meets ADA accessibility requirements for either a front approach or a side approach. When installing this unit, local, state, and federal (including ADA) codes must be adhered to. If height other than shown is required, then dimensions must be adjusted accordingly.
SUPPLY LINE: The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM) flowing pressure. Where sediment or mineral content is a problem, an inlet filter is recommended.
PLUMBING CONNECTIONS: The water supply inlet connection is a 3/8“O.D. compression fitting.
The waste outlet is 1-1/2” PVC pipe. Plumbing connections vary depending on how the unit is configured during assembly. Please consult the installation drawings below for supply and waste fitting arrangements and assembly for your specific model.
MAINTENANCE: Refer to 6518.2FR Operation and Maintenance Sheet for more information.

INSTALLATION PROCEDURE

Follow the installation procedures outlined in the installation diagrams for your specific model below. Note: 3611FR version must be connected to Haws Model 6518.2FR freeze resistant bury valve, sold separately. See 6518.2FR installation manual for instructions.

GENERAL NOTES:

  1. For all compression fitting connections, only connect NSF-61 copper or plastic 3/8” outside diameter tubing. The following assembly instructions must be followed to ensure a watertight connection:
    a. Cut tubing square and clean. Deburr if necessary.
    b. Place compression nut and ferrule over the end of the tubing.
    c. For plastic tubing (must be ¼” inside diameter), insert supplied tubing insert into the end of the tubing.
    d. Push the tube into the fitting until it bottoms out.
    e. Thread nut onto the fitting and tighten snugly with 5/8” wrenches.
Tube Sizes O.D. Tolerance Insertion Depth
3/8” ±.005” 3/4”

TROUBLESHOOTING

PROBLEM REPAIR CHECKLIST
1. Insufficient bubbler flow (FromDrinking Fountain) 1a. Check that the

inlet screwdriver stops valve is wide open (Not Supplied).
b. Verify minimum 30 psi flowing supply pressure.
c. Adjust valve to increase flow. See 6518.2FR Manual.
2. Insufficient bottle filler flow| 2a. Check that the inlet screwdriver stop valve is wide open (Not Supplied).
b. Verify minimum 30 psi flowing supply pressure.
c. Nozzle strainer is clogged. Use a nozzle removal tool to remove the strainer and
replace it. Replacement strainers may be ordered by calling Customer Service.
d. Adjust valve to increase flow. See 6518.2FR Manual.

*For more information about Haws products, see our website: www.hawsco.com

THIS DOCUMENT IS TRUE AND CORRECT AT THE TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.

Haws 3611FR Outdoor Bottle Filler Drinking Fountain -

OPTIONAL ACCESSORIES

3611FR MODULAR OUTDOOR FOUNTAIN SYSTEM
PARTS BREAKDOWN
WHEN ORDERING PARTS, PLEASE SPECIFY THE PART NUMBER

AVAILABLE SUB-COMPONENT MODELS

MODEL 3671 PEDESTAL ARM ASSEMBLY

*MODEL 3680FR FOUNTAIN ASSEMBLY**
(PUSH BUTTON SHOWN IS FOR REF. ONLY, THE ACTUAL PUSH BUTTON IS A DIFFERENT STYLE)

MODEL 3674 PEDESTAL ASSEMBLY

*MODEL 3690FR BOTTLE FILLER ASSEMBLY**
(PUSH BUTTON SHOWN IS FOR REF. ONLY, THE ACTUAL PUSH BUTTON IS A DIFFERENT STYLE)

*FR (FREEZE RESISTANT) MODELS REQUIRE THE USE OF SEPARATE FREEZE-RESISTANT VALVES (NOT SUPPLIED). SEE INSTALLATION DRAWINGS ON THE FOLLOWING PAGES FOR DETAILS.
3611FR MODULAR OUTDOOR FOUNTAIN SYSTEM

PARTS BREAKDOWN
WHEN ORDERING PARTS, PLEASE SPECIFY THE PART NUMBER

1455 KLEPPE LANE
SPARKS, NEVADA  89431
775-359-4712  FAX 775-359-7424
E-MAIL:  HAWS@HAWSCO.COM
WEBSITE: WWW.HAWSCO.COM

ECN: 5652| REV. ECN:
5719| BY:
DP| MODEL(S)
3611FR| PART NUMBER
0580001171
DRAWN: DHP| DATE:
6/11/20| CHK’D.: BMJ| REVISION
2
APPROVED:
FV| DATE: 09/16/21
SCALE:
1:2| DRAWING TYPE: PARTS BREAKDOWN| SIZE:   A| SHEET 1 OF 2

NOTES:
1. WHEN INSTALLING THIS UNIT, LOCAL, STATE, OR FEDERAL CODES SHOULD BE ADHERED TO.
INSTALL A TRAP IN THE WASTE LINE AND A SCREWDRIVER STOP IN THE SUPPLY LINE IF REQUIRED.

Haws 3611FR Outdoor Bottle Filler Drinking Fountain - BUTTONS SHOWN
ARE

HAWS MODEL 3611FR IS FULLY COMPLIANT WITH THE FEDERAL 2010 AMERICANS WITH DISABILITIES ACT (ADA) ACCESSIBILITY REQUIREMENTS WHEN INSTALLED AS SHOWN HERE AND WHEN INSTALLED WITH PROPER CLEARANCES AND ACCESS. LOCATE THE PEDESTAL BASE WITH AT LEAST 8″ OF CLEAR UNOBSTRUCTED HARDSCAPE BEHIND THE PEDESTAL. IT IS THE RESPONSIBILITY OF THE INSTALLER TO ADHERE TO LOCAL, STATE,AND FEDERAL CODES WHEN INSTALLING THIS UNIT.
DISTANCE TO SURROUNDING OBJECTS, APPROACH SURFACES, ETC. SHOULD BE CONSIDERED.

INSTALLATION INSTRUCTIONS

STEP 1
MOUNTING THE PEDESTAL TO THE CONCRETE SLAB IS DESIRED ORIENTATION. SLAB TO BE 30″ MINIMUM SQUARE AND 6″ MINIMUM THICK (BY OTHERS). PLUMBING CAST IN CONCRETE MUST FIT IN A 7″ DIAMETER AREA CENTERED UNDER THE PEDESTAL LOCATION. FOR THE 3611FR MODEL, SEE THE REQUIRED BURY VALVE (NOT SUPPLIED) INSTALLATION REQUIREMENTS ON SHEET 6.| STEP 2
REMOVE BOTTOM COVER PLATES FROM ARMS BY
REMOVING 3 1/4″ BUTTON HEAD SCREWS.
INSTALL ONE FOUNTAIN ARM ON THE RIGHT SIDE AS SHOWN. USE 1/4″ FLAT HEAD SCREWS (SUPPLIED) TO INSTALL THE PLATE. USE 3/8″ BOLTS AND NUTS (SUPPLIED) AND TORQUE TO 18 FT-LBS TO INSTALL THE ARM.
---|---

NOTE: PUSH BUTTONS SHOWN ARE FOR REF. ONLY, ACTUAL PUSH BUTTONS ARE DIFFERENT STYLES.

STEP 3
PLACE SQUARE TRIM RING ON BOTTOM OF BOTTLE FILLER AND PLACE BOTTLE FILLER ON TOP OF PEDESTAL, FACING THE FRONT. USE 3/8″ BOLTS AND NUTS VIA THE FRONT ACCESS PANEL TO SECURE THE BOTTLE FILLER TO THE PEDESTAL.
PLACE TRIM RING AND INSTALL FOUNTAIN ON ARM AS SHOWN. CAREFULLY CENTER BOTTLE FILLER, FOUNTAIN, AND TRIM RINGS, THEN TORQUE BOLTS/NUTS TO 18 FT-LBS

Haws 3611FR Outdoor Bottle Filler Drinking Fountain - ADAPTER IS
GLUED

STEP 4
INSTALL SUPPLIED DRAIN COMPONENTS AS SHOWN. RED COMPRESSION WASHERS ADAPT FROM 1-1/4″ TO 1-1/2″ AT EACH DRAIN TAILPIECE. BLACK COMPRESSION WASHERS ARE USED IN TRAP ADAPTERS AT TEE. USE APPROPRIATE PVC CEMENT TO MAKE SOLVENT CEMENT CONNECTIONS.
TRIM WASTE BEND AND/OR TAILPIECE LENGTH IF REQUIRED. NOTE THAT EXTRA PARTS MAY BE INCLUDED TO FACILITATE OTHER CONFIGURATIONS OF THIS FOUNTAIN.

STEP 5
COMPLETE WATER SUPPLY PLUMBING AS SHOWN. OPEN SUPPLY VALVE(S) AND TEST. REPLACE ARM BOTTOM PLATE AND PEDESTAL ACCESS PLATES. BURY VALVES (NOT SUPPLIED) ARE REQUIRED FOR 3611FR INSTALLATION. REFER TO THE BURY VALVE OPERATION AND MAINTENANCE MANUAL FOR ADDITIONAL INFORMATION.

  • SEE THE NEXT SHEET OF THIS DRAWING FOR MORE INFORMATION ON INSTALLING BURY VALVES WITH THIS MODEL.

Haws 3611FR Outdoor Bottle Filler Drinking Fountain - 3611FR GENERAL
BURY

INSTALL BURY VALVES IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS.
INSTALLATION MUST COMPLY WITH LOCAL CODES / STANDARDS, INCLUDING ADA CODES IF APPLICABLE.

NOTES ON OPTIONAL CONFIGURATIONS

HAWS 3600FR SERIES OUTDOOR FOUNTAINS ARE MODULAR AND CAN BE ASSEMBLED AND CONFIGURED IN MANY DIFFERENT WAYS. DISPLAYED HERE ARE A FEW EXAMPLES. CONFIGURATIONS OTHER THAN THAT SHOWN IN THE INSTALLATION INSTRUCTIONS FOR THE 3611FR MAY AFFECT COMPLIANCE WITH ADA REGULATIONS. IT IS THE RESPONSIBILITY OF THE INSTALLER TO UNDERSTAND LOCAL, STATE, AND FEDERAL REGULATIONS AS APPLICABLE IF INSTALLING THIS FOUNTAIN IN CONFIGURATIONS OTHER THAN THAT INDICATED ON SHEET 1 (PAGE 6 OF 12).

NOTE: PUSH BUTTONS SHOWN ARE FOR REF. ONLY, ACTUAL PUSH BUTTONS ARE DIFFERENT STYLES.

1455 KLEPPE LANE
SPARKS, NEVADA  89431
775-359-4712  FAX 775-359-7424
E-MAIL:  HAWS@HAWSCO.COM
WEBSITE: WWW.HAWSCO.COM

ECN: 5652| REV. ECN:
5719| BY: DP| MODEL(S)
3611FR| PART NUMBER
0580001171.D
DRAWN: DHP| DATE:
6/11/20| CHK’D.: BMJ| REVISION
2
APPROVED:
FV| DATE: 09/16/21
SCALE:
1:2| DRAWING TYPE: PARTS BREAKDOWN| SIZE:   A| SHEET 1 OF 2

1455 Kleppe Lane Sparks, NV 89431-6467 775-359-4712
Fax 775-359-7424
E-mail: haws@hawsco.com 
website: www.hawsco.com
No. 0580001171 (2)
© 2021 Haws Corporation – All Rights Reserved.
HAWS® and other trademarks used in these materials are the exclusive property of Haws Corporation.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals