Haws 3603FR Outdoor Triple Drinking Fountain User Manual

June 9, 2024
haws

Haws 3603FR Outdoor Triple Drinking Fountain

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
1455 Kleppe Lane Sparks,
NV 89431-6467
775-359-4712
Fax 775-359-7424
E-mail : haws@hawsco.com 
Website: www.hawsco.com

MODEL 3603FR
Outdoor Triple Drinking Fountain
NOTE TO INSTALLER : Please leave this informat ion with the Maintenance Department.

LIMITED WARRANTY

HAWS warrants that all of its products are guaranteed against defective material or poor workmanship for a period of one year from the date of shipment. The foregoing notwithstanding, HAWS warrants certain specific products or components thereof for an adjusted period. A list of these excepted products and components and a description of their respective warranty terms may be found here: www.hawsco.com/warranty. HAWS’ liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first-class workmanship, provided that a claim is made in writing to Company within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS shall not be liable for the cost of repairs, alterations or replacements, or the labor required to implement them, or for any expense connected therewith made by the owner or owner’s agents, except upon written authority from HAWS. HAWS shall not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that HAWS has made no other warranties either express or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, incidental, or consequential damages claimed to arise under the contract of sale.
Equi pment manufactured by HAWS is warranted to function if installation and maintenance instructions prov ided are adhered to. The units also must be used for the purpose for which they were intended. Any HAW S emergency equipment is intended to supplement first-aid treatment. Due to widely varying conditions, HAW S cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggrav ation of existing or prior injuries.
EX CEPT AS EXPRESSLY STATED HEREIN, HAWS HEREBY DISCLAIMS ALL WARRANTIES, WHE THER EXPRESS OR IMPLIED, ARISING BY LAW OR OTHERWISE, INCLUDING WITHOUT LIMI TATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PART ICULAR PURPOSE. THIS WARRANTY MAY NOT BE MODIFIED OR EXTENDED WITHOUT THE WRIT TEN CONSENT OF HAWS. REMEDIES AND REPLACEMENTS STATED HEREIN ARE EX CLUSIVE. IN NO EVENT SHALL HAWS BE LIABLE FOR ANY SPECIAL, PUNITIVE, CO NSEQUENTIAL OR INCIDENTAL DAMAGES TO ANY PERSON INCLUDING BUT NOT LIMITED TO DAMAG ES FOR LOSS OF USE OR PROFITS, SUBSTITUTE PRODUCTS OR COSTS, PROPERTY DAMAG E, OR OTHER MONETARY LOSS.

SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
FOR CUSTOMER SERVICE: 1-888-640-4297

RECOMMENDED TOOLS

  • Measuring Tape
  • PVC Pipe Cutter
  • Plastic Tubing Cutter
  • PVC Solvent Weld Glue
  • ¼” Bit-Holding Screwdriver
  • Level
  • 10” Pipe Wrench
  • Adjustable Plier
  • 1/8 and 5/32 Tamper Resistant Hex Bits (Supplied)
  • 9/16” and 5/8” Box/Open Combination Wrenches, 8” Max Length
  • 3/8” Socket Wrench/Rachet, 8” Max Length
  • 9/16” Deep Socket
  • 15/16” Socket

LOCATION OF UNIT: The Model 3603FR Drinking Fountain can be installed and assembled to be ADA accessible by first locating the pedestal base with at least 8 inches of clear unobstructed hardscape behind the pedestal. Provide hardscape that is at least 74 inches wide. When the right pedestal arm is installed in the high orientation, the height dimensions shown on the model specification sheet meet current Federal Americans with Disabilities Act (ADA) wheelchair requirements. When a fountain is installed on top of the pedestal, the height dimensions shown on the model specification sheet meet current ADA standing height requirements. When installing this unit, local, state and federal (including ADA) codes must be adhered to. If height other than shown is required, then dimensions must be adjusted accordingly.

SUPPLY LINE: The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM) flowing pressure. Where sediment or mineral content is a problem, an inlet filter is recommended.

PLUMBING CONNECTIONS : Water supply inlet connection is a 3/8“O.D. compression fitting. Waste outlet is 1-1/2” PVC pipe. Plumbing connections vary depending on how the unit is configured during assembly. Please consult the installation drawings below for supply and waste fitting arrangements and assembly for your specific model.

MAINTENANCE: Refer to 6518FR & 6518.2FR Operation and Maintenance Sheet for more information.

INSTALLATION PROCEDURE

Follow the installation procedures outlined in the installation diagrams for your specific model below. Note: 3603FR version must be connected to Haws Models 6518FR & 6518.2FR freeze resistant bury valves, sold separately. See 6518FR & 6518.2FR installation manuals for instructions.
GENERAL NOTES:

  1. For all compression fitting connections, only connect NSF-61 copper or plastic 3/8” outside diameter tubing. The following assembly instructions must be followed to ensure a watertight connection:
    • a. Cut tubing square and clean. Deburr if necessary.
    • b. Place compression nut and ferrule over end of tubing.
    • c. For plastic tubing (must be ¼” inside diameter), insert supplied tubing insert into end of tubing.
    • d. Push tube into the fitting until it bottoms out.
    • e. Thread nut onto fitting and tighten snugly with 5/8” wrenches.

 | Tube Sizes| O.D.

Tolerance

| Insertion Depth|
---|---|---|---|---
3/8”| ±.005”| 3/4”
TROUBLESHOOTING
 | PROBLEM|  |  | REPAIR CHECKLIST
1.| Insufficient bubbler flow| 1a.| Check that inlet screwdriver stop valve is wide open (Not Supplied)
 |  | b| .     Verify minimum 30 psi flowing supply pressure.
 |  | c.| Adjust valve to increase flow. See 6518FR or 6518.2FR Manual*.

*For more information about Haws products, see our website: www.hawsco.com
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.

REPLACEMENT PARTS

Haws-3603FR-Outdoor-Triple-Drinking-Fountain-fig-1

OPTIONAL ACCESSORIES

3603FR
MODULAR OUTDOOR FOUNTAIN SYSTEM

PARTS BREAKDOWN

AVAILABLE SUB COMPONENT MODELSHaws-3603FR-Outdoor-Triple-Drinking-
Fountain-fig-3

*FR (FREEZE RESISTANT) MODELS REQUIRE THE USE OF SEPARATE FREEZE RESISTANT VALVES (NOT SUPPLIED). SEE INSTALLATION DRAWINGS ON THE FOLLOWING PAGES FOR DETAILS.

NOTES:

  1. WHEN INSTALLING THIS UNIT, LOCAL, STATE, OR FEDERAL CODES SHOULD BE ADHERED TO. INSTALL A TRAP IN THE WASTE LINE AND A SCREWDRIVER STOP IN THE SUPPLY LINE IF REQUIRED.
  2. ARM HEIGHT CAN BE CONFIGURED AS DESIRED, REFER TO SHEET 7 FOR ALTERNATE CONFIGURATIONS
  3. MAXIMUM ADJUSTABLE RANGE IS 15 FROM PARALLEL TO BACK OF WALL.

Haws-3603FR-Outdoor-Triple-Drinking-Fountain-fig-4

INSTALLATION INSTRUCTIONS

Haws-3603FR-Outdoor-Triple-Drinking-Fountain-
fig-5Haws-3603FR-Outdoor-Triple-Drinking-
Fountain-fig-6Haws-3603FR-Outdoor-Triple-
Drinking-Fountain-fig-7Haws-3603FR-Outdoor-
Triple-Drinking-Fountain-fig-8Haws-3603FR-Outdoor-Triple-Drinking-Fountain-fig-9

NOTES ON OPTIONAL CONFIGURATIONS
HAWS 3600FR SERIES OUTDOOR FOUNTAINS ARE MODULAR AND CAN BE ASSEMBLED AND CONFIGURED MANY DIFFERENT WAYS. DISPLAYED HERE ARE A FEW EXAMPLES. CONFIGURATIONS OTHER THAN THAT SHOWN IN THE INSTALLATION INSTRUCTIONS FOR THE 3603FR MAY AFFECT COMPLIANCE WITH ADA REGULATIONS. IT IS THE RESPONSIBILITY OF THE INSTALLER TO UNDERSTAND LOCAL, STATE, AND FEDERAL REGULATIONS AS APPLICABLE IF INSTALLING THIS FOUNTAIN IN CONFIGURATIONS OTHER THAN THAT INDICATED ON SHEET 1.Haws-3603FR-Outdoor-Triple-Drinking-Fountain-
fig-10© 2022 Haws Corporation – All Rights Reserved. HAWS® and other trademarks used in these materials are the exclusive property of Haws Corporation.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals