Panasonic BR-1271HP-AUH Commercial Refrigerator Instruction Manual
- October 30, 2023
- Panasonic
Table of Contents
Operation Instructions
Commercial refrigerator
MODEL
Commercial refrigerator
BR-1271HP(AUH) | BR-1261HP(AUH) |
---|---|
BR-1571HP(AUH) | BR-1561HP(AUH) |
BR-1871HP(AUH) | BR-1861HP(AUH) |
Structure of Refrigerated Cabinet
Selection of Installation Site
- Please try to avoid acid, alkali and other environments containing corrosive components. Such environment will corrode mechanical parts of products, resulting in failure.
- Please leave more than 30cm above the cabinet body space for ventilation. Please put it in a place with the ambient temperature at 5-35°C.
- Please place it in a vertical or slightly inclined backwards place for installation.
- The product shall be installed on a ground is anti-water dropping and immersion and is easy for drainage.
- Please try to avoid direct sunlight or heating appliances, otherwise it would reduce the cooling capacity.
- Do not use it in outdoor. If use it under rain, leakage of electricity electric shock and other accidents may occur. In addition, please avoid water pipe, water tank and other places that are humid or vulnerable to splash water.
Matters Need Attention
Cautions
-
Danger
①Please do not put dangerous articles which are volatile, flammable or explosive into the cabinet, otherwise explosion and fire may occur.
②When abnormal matters occur, please cut off the power and stop the running, otherwise electric shock and fire may happen.
③ The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
④ Children being supervised not to play with the appliance. -
Warnings
① Other persons apart from manufacturer and professional maintenance personnel appointed by the manufacturer shall not dismantle the cabinet to repair or transform. When parts and components are damaged or need to be changed, please contact with the manufacturer or professional personnel. In the repairing, do not transform the parts and components as well as materials of the parts and co moments. If wires provided as repairing parts break, please change the whole wire instead of repairing and connecting the broken wires. Incorrect operations may damage the cabinet and improper repairing may cause electric shock and fire. In the repairing and transform, parts and components of the cabinet shall be placed properly to prevent dangers caused by dropping and turning of parts and components. Repairing personnel shall wear protective equipment.
② Leakage protector shall be equipped and the power socket shall have reliable ground connection. Please check and confirm the leakage breaker regularly. If leakage breaker which is out of order is used, when the electricity leakage happen, the leakage breaker will not work, which will cause electric shock. Do not connect the power line and extended line with medium lines or share power with other appliances. Quick connection terminal shall be inserted and pulled out straightly and turning should be prevented. When inserting and pull ing the plug, please hold the top of the plug. Pulling the wire may ca use breakage of the wire, which may cause the hot wire or fire. Do not cut off the power frequently. The electric pressure of the working supplying power can float around the rated voltage. The floating range shall be±10%.
The connection method of this product is Y connection. If the power line is broken, in order to prevent dangers, please inform the manufacturer and personnel in maintenance department or similar departments to change the wires.
③ Please do not put hands on the mechanical parts such as fans which are turning rapidly or hot pipes, otherwise you may be cut or scalded.
④ When cleaning the cabinet, please cut off the power, otherwise electric shock or hurts caused by fans shall happen.
⑤ Please do not put hands in the outlet and inlet openings of the air, otherwise damages may occur due to rapid turning of the internal fans.
⑥ Please do not put bottled articles or canned articles in freezing chimer, otherwise the bottle or can may be burst, which may incur damages.
⑦ When the product will not be used for a long term, please pull out the plug or cut off the power for your safety, otherwise hot cabinet or fire may happen. Please take all things in the cabinet out and clean the cabinet. Please open and dry the cabinet to prevent the cabinet from corrosion. Please put the product in a place where children will not play. Take measures such as paste materials such as wood and so on between the door and main body of the cabinet to guarantee that the door will not closed and seal the cabinet.
⑧ When cleaning and picking filter net of the condenser, please do not touch the fins of the condenser directly with hands, otherwise you may be hurt.
⑨ For fluorescent lamp with two plugs, the same fluorescent pipes shall be used when changing the pipes and the changing shall be taken by professional personnel. The power should be cut, that is to say pull the power plug out.
⑩ When closing doors with locks, please confirm that nothing besides the stored things is in the cabinet before locking the door, in case children are locked into the cabinet. Please put the key in safe place.
⑪ Material of foam layer. Material of foam layer is flammable. Pay attention to the warning of “Watch out Fire” on the cabinet.
⑫ The external LED must be replaced by the same kind of LED and replaced by professional staff, and the power cut-off operation is required which is remove the power plug.
⑬ Before moving the freezer or the refrigerator ,the cabinet must be emptied. Other wise, all the consequences will be on your own. -
Attentions
① When disposing of this refrigerator, remove the door/door seals and door latch so that small children or animals cannot become trapped inside.
Children should be supervised to ensure that they do out play with the appliance. If trapped inside, a child may get hurt or suffocate to death.
If trapped inside,the child may become injury and suffocate to death.
Cyclopentane is used in the insulation. The gases in the insulation material require a special disposal procedure. Please contact your local authorities. in regard to the environmentally safe disposal of this product.
② If the product breaks down, food in the cabinet may go bad.
③ Please do not take food or containers from freezing chamber when your hands are wet, especially the metal containers, otherwise hurt may be caused.
④ Do not carry the product with hands. Please contact with agency shop and professional personnel. Please pull the power line off and do not scratch the power wire. If the power wire is damaged, electric shock or fire may be caused. Please take out the stocks and retainers, for the dropping of these things may cause hurt for people. Please pay enough attention to the dropping of the cabinet, otherwise hurt may be caused.
⑤ Do not pour water on the cabinet, otherwise short circuit or electric shock may happen.
⑥ Do not throw things in the net rack, otherwise the dropping of the net rack may damage the cabinet.
⑦ The transportation and packing tearing shall be carried out by professional personnel with protective equipment.
⑧ Before transferring the cabinet, please pay attention to that:
(1) When the packing and rubber belts are removed, the packing and dismantled nails shall be disposed by professional personnel. Please open the door of the cabinet to change the air.
(2) The cleaning has been completed before the packing and please clean the inside part of the cabinet again.
(3) Before using the cabinet, please connect to the power for an hour to confirm that the refrigeration runs normally.
⑨ Fixation of the cabinet. Most cabinets in this series use the fixation legs.
When the product is put in the arranged position, it is not easy to move it. For supporting of cabinets of special models, mobilizable legs can be used. Before using the cabinet after the cabinet is placed in the arranged position, the legs shall be adjusted to locking situation, otherwise the cabinet will move easily and damage other things or hurt people.
⑩ Please pay attention to the following content before putting foods in the cabinet:
(1) Before storing the foods, please pay attention to the validation period of the foods. The foods which are put firstly shall be taken out firstly.
(2) Hot food cannot be put in before it becomes cool to prevent that the quality of the surrounding food is reduced.
(3) Please put the food in sealed bags or other sealed containers to prevent that the flavor is mixed and the food is dried.
(4) This product is suitable for materials for pastry,
⑪ Energy Saving
(1)The opening times and closing times of the door of the cabinet shall be as less as possible. The time when the door is open shall be as short as possible. The door should be sealed.
(2) Set suitable temperature. If the refrigeration temperature is not proper ,waste will be caused.
Instructions
-
Parameters setting
St will display in 3 seconds after press , then press again to show St parameters. Press or to adjust temperature and press to apply changes. Settings will be automatically applied after 30 seconds if no further operation. -
Forced defrosting
Keep pressing for more than 3 seconds to start defrosting (Evaporator temperature should be lower than the defrosting termination temperature and the overheat protectories not triggered. -
Lighting
The light will be on when power-on by default setting, pls press to turn on & off.
Range of temperature setting Refrigerated cabinet:-2~ 10 ℃【Indicating Lights Instructions】
Indicator | Symbol | Status | Description |
---|---|---|---|
Compressor | on | Compressor on | |
off | Compressor off | ||
Fan motor | on | Fan motor on | |
off | Fan motor off | ||
Malfunction | on | Malfunction occurs | |
off | No malfunction | ||
Setting | on | Parameter setting | |
off | Observe and control | ||
Defrosting | on | In process of defrosting | |
off | Defrosting completed | ||
Defrost dripping | on | In process of defrost dripping | |
off | Defrost dripping completed | ||
Lighting | on | Lighting on | |
off | Lighting off |
If any situation in the following table occurs, please make examination according to the corresponding item.
Indication | Instructions | Examination Key Point |
---|---|---|
rH | The temperature in the cabinet is12°C higher than the set temperature, and |
the operation under this temperature has kept on for more than two hours. The
indicated temperature is the temperature in the cabinet.| 1. cv Whether the
door is closed?
2. Whether hot food is put in?
rL| The temperature in the cabinet is 1 °C lower than the set temperature, and
the operation under this temperature has kept on for more than two hour. The
indicated temperature is the temperature in the cabinet.| Whether frozen foods
are put in the cabinet which are melting?
CH| The temperature of the export for the condenser is more than 63°C and the
condenser has operated under this temperature for more
than 90 minutes. The indicated temperature is the temperature in the cabinet.|
w Whether the filter
net is blocked?
c?), Whether the surrounding temperature is too high?
,.,
Cr| The temperature of the export for the condenser is more than 70°C|
If reason above are excluded and the operation of the cabinet is not normal or
the temperature is indicated as H1,H2,L1,L2 it is considered that the heat
detector or other parts are abnormal.
When this kind of problem occur, please contact with the retailer or consult
in the customer’s service window.
On Defrosting
The cabinet makes use of heater strip to defrost. Microcomputer will control
the defrosting time. When the defrosting is carried out, the temperature in
the cabinet is indicated as [dEF]. The refrigeration will restart again
automatically five minutes after the defrosting is finished. (With ten minutes
after the defrosting has finished, in order preventing the temperature in the
cabinet from increasing, the cooling fan will not run.)
When defrosting, the temperature in the cabinet will increase in some degree,
which has little effect on the temperature of foods.
Therefore, it is not necessary to take the foods in the cabinet out.
When defrosting, the water flowing from the sides of the units will be
discharged from the accessary exhaust water pipe. If there is no outfall near
the cabinet, please connect the exhaust water pipe with other pipes and drain
the water to the outfall.
During the defrosting or after the defrosting for a short time when the
temperature is the highest, the largest indication or largest measurement
value of the temperature sensor is -3.2℃.
Method of Application Please pay attention not to block the channel for cool air and guarantee that the cool air can cycle smoothly.
For products with mobile middle column, when the door of the cabinet is closed, please pay attention to the warning label in the mobile middle column. If the label is not towards to the cabinet, please turn the mobile middle column for 90°and the close the door.
Cleaning and Maintenance
Please keep the refrigerated cabinet clean.
-
Cleaning of cabinet body
Use a cloth moistened with mild detergent to wipe off the dirt, then use a cloth moistened with water to wipe, and lastly wipe dry with a dry cloth.
Do not use cleaning powder, acids, volatile oil, gasoline, thinner, boiled water and other substances that can cause material damage. -
Filter screen of condenser
Remove it 1~2 times every month for cleaning. When it is very dirty, please use the neutral detergent to clean.
1. Firstly dismount the fastening screw when the baffle is open. The filter screen can be dismounted by lifting the grilled door.
2. When the filter screen is dismounted, firstly lift it and then take it out. -
Condenser
Clean once every half a year according to the sequences as shown below.
1. Disconnect the power plug from the socket.
2. Hold the under part on two sides with hand and pull forward ,turn a little and lift up to remove it.
3. Use the brush to brush from top to bottom, thoroughly brushing the dust. If the condenser filter is removed for cleaning, do not directly touch the condenser fin, which may cause injury.
-
Door seal
If continue to use it under the condition that it is stained with lactic acid bacteria beverage or seasonings, door edge will be damaged. Do not forget to clean the door edge and the surface contacted with edge. -
After the maintenance completes, the following inspection shall be made for safety.
1. Whether the power line plug is completely inserted in the power socket or not. Whether there is abnormal heating phenomenon or not.
2. IF the supply cord is damaged. It must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
About After-sale Service
Description | Showed on the nameplate |
---|---|
Purchase date and designation | Recorded in the guarantee |
Status of failure | Knowing the detailed about the failure |
Address, name and TEL number | Let targeted person known |
Interview date | Please let we know your free time |
- Free warranty period:As the product is used as commercial equipment, warranty period of the complete machine is twelve months since the day of installation, acceptance and delivery or the day that the customer begins to use.
- If the machine fails by complying with the instructions for use and operative precautions, please dial our toll-free number to report for repair.
- Within the warranty period, the company provides free repair for the products supplied or products of affiliate enterprise. If it cannot be repaired, new parts shall be timely replaced for free.
- Within the warranty period, if one of the following circumstances occurs,we will provide pay-needed maintenance.
① Components of the product damage or are lost when the customer is responsible for transportation.
② Customers carry, install, operate, transform or conduct maintenance without complying with the Operation Instruction.
③ The machine is left unused for a long time during the warranty period so that corrosion, damage, loss, etc. generate
④ Due to customer’s own causes.
⑤ Failure or damage, such as fire, abnormal voltage, flood etc. caused by force majeure.
⑥ Do not purchase invoice or change and alter invoices without permission.
⑦ Consumables are not covered by the warranty, such as fluorescent lamp, display lamp, starter, battery of temperature display, glass and so on.
General Failure and Inspection
If the performance becomes bad in the progress of use, please check the following items!
Fault phenomenon | Key point for ins inspection |
---|---|
Not cold at all | -Whether power fails or not. |
•Whether the power line plug is inserted in the power socket or not.
•Whether the leakage circuit breaker works or not (under the condition of
being installed with leakage circuit breaker) .
Bad cooling effect| •Whether the temperature setting is appropriate or not.
•Whether the food blocks the cold air outlet and inlet or not.
•Whether too much food is put in or not.
•Whether the cabinet door is opened too frequently or open or not.
•Whether the filter screen of condenser is too dirty or not.
Too loud sound| •Whether the adjustable food contacts with the ground or not.
•Whether the back contacts with the wall or not.
•Whether the basin or other container falls around or not.
Condensation (Outer surface)| •In the continuous hot weather, condensation may
form on the outer surface. The reason is that in the case of high temperature,
condensation forms on the surface when the moisture in the air contacts with
cold substance. This is not a failure. When such phenomenon occurs, use a dry
cloth to wipe clean.
Cabinet door cannot close| •Whether the cabinet door edge is clamped or not.
•Whether the product leans forward or not.
Parts
| BR-1261HP (AUH)
BR-1271HP (AUH)| BR-1561HP (AUH)
BR-1571HP (AUH)| BR-1861HP (AUH)
BR-1871HP (AUH)
---|---|---|---
Net rack| 1| 1| 1 small net racks 1 big net racks
Support| 5| 5| 9
Safety Cautions/Warnings
For the purpose of avoiding harm to people and damage to properties, items to
be complied with are explainec here.
NI Explanations are classified by degree of harm or damage caused by incorrect
use.
Warning Indicates possibility of death or serious injury.
Caution Indicates possibility of minor injury or damage to properties.
Items to be observed are explained by the following pictograms.
****Indicates what you should not do.
Indicates what you must do.
Warning
Installation Work
Request a specialty operator to perform installation by conforming to the
installation instructions.
Incorrect installation work may lead to malfunction such as abnormal
vibration, and generates refrigerant gas leak, electrical shock, or fire.
Installation should be made securely on a place that can fully support the
mass of the refrigeration unit
Insufficient foundation may cause failing or dropping, and lead to refrigerant
gas leak, injury, electrical shock, or fire.
- Refrigeration unit should be secured on a concrete base with a mass approximately 3 times that of the unit and fastened with anchor
Install the safety cover.
Touching the refrigeration unit by hand of the people other than the
designated operators may cause injury.
- Install a safety cover or protective
Do not use other than the designated refrigerant (for charging, adding or
recharging)
Non-designated refrigerant may cause equipment failure or burst, or injury.
Securely complete refrigerant piping before carrying out airtight testing.
Refrigerant gas leak may cause suffocation.
Perform airtight test before charging refrigerant.
Refrigerant gas leak may cause insufficient oxygen and lead to a death
accident.
- Carry out airtight test and confirm no leak of
Piping, equipment components and tools should be exclusively for R744 (CO2
refrigerant).
Use of components for HFC refrigerant cay cause serious accidents such as
equipment failure and rupture of the refrigerant cycle.
Be sure to comply with following
Repairs
Disassembly or repairs should be performed by a specialty operator.
Incorrect disassembly or repair may lead to abnormal operation and causes
injury, fire or electrical shock.
Request a specialty operator to perform disassembly or repair work.
Do not absolutely perform modification.
When abnormal operation was detected, or before starting disassembly or
repair, turn off the power switch and shut off the ground fault interrupter.
Continued operation with abnormal condition, or disassembly/repair without
shutting off the power would lead to current leak or short-circuit and may
cause fire or electrical shock.
Specified components must be used for repair.
Use of non-specified components may cause failure of the safety stop function
and lead to burst or fire.
- Consult with the distributor.
Stop the compressor before disconnecting the refngerant piping.
Disconnecting the piping while the compressor is in operation would cause
abnormally high pressure with air intake, and may lead to a burst or injury.
Moving or Change of Installation Location
Request a specialty operator for moving or changing the location. Incorrect
installation or moving work may lead to malfunction such as abnormal
vibration, and generates refrigerant gas leak, electrical shock, or fire.
WARNING: Keep clear of obstruction all ventilation openings in the a
ppliance enclosure or in the structure for building-in.
WARNING: Do not use mechanical devices or other means to accelerate the
defrosting process, other than those recommended by the manufacturer.
WARNING: Do not damage the refrigerating circuit.
WARNING: Do not use electrical appliances inside the food/ice storage
compartments unless they are of the type recommended by the manufacturer.
Caution for Use
When the refrigerant bursts out, shut off the power and fully close the
service valve.
Blowout of refrigerant from the refrigeration cycle by opening the service
port would cause insufficient oxygen and harm human health.
Do not touch electrical components by a wet hand.
Switching operation by a wet hand may cause electrical shock and injury.
Periodically check operation of the ground fault interrupter.
Failed interrupter does not operate safety stop function and may lead to fire
or electrical shock.
Do not ride on the refrigeration unit.
Riding on the refrigeration unit or placing an article on it may lead to
falling or dropping by vibration and cause injury.
Periodically check the installed base.
Damaged base after a long-time use may cause the refrigeration unit to fall or
drop and lead to injury.
Do not use flammable spray near the refrigeration unit. Do not place flammable
materials nearby.
Flammable material may catch fire from switch spark.
Before any inspection service, turn off the power switch and shut down the
ground fault interrupter.
Inspection work with power on may lead to electrical shock, interference with
the moving mechanism, and heat generation, thereby leading to injury and skin
bum.
When removing the fin guard of the gas cooler, do not touch the fin.
Touching the fin and sliding along the fin may cause skin cut by the fin edge.
Do not operate with the service valve closed.
Operation with the high pressure service valve closed would cause abnormal
high pressure and may lead to a burst.
Main Technical Parameters
Description | Commercial refrigerator | |
---|---|---|
Model Number | BR-1271 HP (AUH) | |
Dimensions | Overall Dimensions(ivxDxH)(ran) | 1200×750(+40)x850 |
1500×750(+40)x850 | 1800×750(+40)x850 | |
Dimensions(WxDxifi(m) | 794x587x573 | |
Overall effective volume | 280L | |
Overall installation dimension | 1200x750x850 | |
Overall operation dimension | 1200x1147x850 | |
Net rack | Net rack painted with polyethylene | |
Max. quanity of net rack | 1 | |
Max. workload of net rack | 80kg | |
Available area of refrigeration net rat. | 0.43m: |
R:0.49m.
Rated frequency| | 50Hz
Rated voltage| | 220-240V
Rated current| | 1.4A
Total power input| | 260W
Total power input of defrosting| | 247W
Rated power input of other thermoelectric element| 35W| I| 41W| I 57W
| Condition| External air temperature is 30 C Without load balancing and
direct sunlight shining
Internal Temperature| | Below 3 °C
Temperature Setting Range| | -2–10°C
Climate type| | 4
Compressor model| | NSG45NA
| Refrigerator| | See the Dimensions
Dimensions| Blower| For Chiller| | DC 12V 6W
For Condenser| | DC 12V 8.4W
Power| Power| | 240V- 50Hz
Power
Cord| Length| | 3 . 0 m
Plug| With ground terminal two-pole plug (Type I protection)
Applicable Socket| | With ground terminal two-pole plug 10A 250V
protect OrtIngai 1188 15y| | Type I
Material of foam layer| | Polyurethane
Foaming agent| | Cyclopentane
Weight| 94kg| | 105kg| 125kg
Note:
- If parameters in the table change, please refer to the nameplate.
- Loading of net rack shall not exceed the values listed in the technical parameter table, otherwise, it may render net rack to fall, causing damage.
- Description for the meaning of climate type
Climate type code | Meaning description |
---|---|
SN,N,ST,T | SN |
N | Temperate zone: 16°C —32°C |
ST | Subtropical zone: 18°C —38°C |
T | Tropical zone: 18°C —43°C |
Table 1 (Applicable to freezer with the volume<500L)
Climate type code | Temperature and humidity condition |
---|
Dry-bulb
temperature °C| Relative
humidity %
1| | 16| 80
2| | 22| 65
3| | 25| 60
4| | 30| 55
5| | 40| 40
Description| | Commercial refrigerator
---|---|---
Model Number| BR-1261HP (AUH)| | BR-1561HP (AUH)| BR-1861HP (AUH)
Dimensions| Overall ,,
Dimensions( IN xDxF1 ) OM)| 1200×600(+40)x850| | 1500×600(+40)x850| 1800
x600(+40)x 850
Dimensions (WxDxFI)| 794×437 x573| | 1094 x437x573| 1394x437x573
Overall effective volume| 214L| | 296L| 377L
Overall installation dimension| 1200x600x850| | 1500x600x850| 1800x600x850
Overall operation dimension| 1200x997x 850| 1500×1144450| 1800x1047x850
Net rack| Net rack painted with polyethylene
Max. quantity of net rack| | 1
Max. workload of net rack| 80kg| | 100kg| L: 40kg R:80kg
Available area of refrigeration net rac| 0.32m’| | 0.44m’| L: 0.18 rit R:0.38
rri’
Rated frequency| | 50Hz
Rated voltage| | 220-240V
Rated current| | 1.4A
Total power input| | 260W
Total power input of defrosting| | 247W
Rated| Rated frequency| 35W| | 41W| 57W
Performance| Condition| External air temperature is 30 C Without load
balancing and direct sunlight shining
Internal Temperature| | Below 3 -C
Temperature Setting Range| | -2^-10t
Climate type| | 4
Compressor model| | NSG45NA
| Refrigerator| | See the nameplane
Freezing
Assembly| Blower| For Chiller| | DC 12V 6W
For condenser| | DC 12V 8.4W
Power| Power| | 240V— 50Hz
Power
Cord| Length| | 3. 0 m
Plug| With ground terminal two-pole plug (Type I protection)
Applicable Socket| | With ground terminal two-pole plug 10A 250V
Overall Dimensions| | Type I
Material of foam layer| | Polyurethane
Foaming agent| | Cyclopentane
Weight| 88kg| | 96kg| 114kg
Panasonic Appliances Cold Chain (Dalian) Co., Ltd.
Add: No.6,Songlan Street, Dalian Economic and Technological Zone, China
Made in China
8DM-6-P110-267-00
Documents / Resources
|
Panasonic BR-1271HP-AUH Commercial
Refrigerator
[pdf] Instruction Manual
BR-1271HP AUH, BR-1571HP AUH, BR-1871HP AUH, BR-1261HP AUH, BR-1561HP AUH, BR-
1861HP AUH, BR-1271HP-AUH Commercial Refrigerator, Commercial Refrigerator,
Refrigerator
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>