BAYSIDE 106cm Stroll Dc Ceiling Fan Installation Guide
- September 27, 2024
- BAYSIDE
Table of Contents
106cm Stroll Dc Ceiling Fan
“`html
Product Information
Specifications
- Product Name: BAYSIDE STROLL DC CEILING FAN
- Model: V1.0-AU (05/2024)
- Features: 6-speed remote control, designed for enhanced comfort
levels
Product Usage Instructions
Safety Precautions
Before using the BAYSIDE STROLL DC CEILING FAN, please ensure to
follow these safety precautions:
-
Do not use the fan if there is any unusual wobbling or
oscillating movement. Contact the manufacturer in such cases. -
Ensure proper installation by a licensed electrician.
-
Supervise children around the fan to prevent accidents.
Installation Instructions
-
Mount the fan assembly using the provided mounting bracket and
screws. -
Ensure the down rod with ball joint is securely attached for
proper installation. -
Install the light kit extension cable if required.
-
Securely mount the remote receiver and controller for
convenient operation.
Maintenance
Regular maintenance of the BAYSIDE STROLL DC CEILING FAN is
essential to ensure optimal performance. Follow these maintenance
tips:
-
Keep the fan clean by dusting regularly.
-
Check for any loose screws or parts and tighten them if
necessary. -
Replace batteries in the remote control when needed.
Warranty Information
Ensure that the installation of the fan includes an all-pole
disconnection switch as per local wiring rules to avoid voiding the
warranty.
FAQ
Q: Can I install the BAYSIDE STROLL DC CEILING FAN myself?
A: It is recommended to have the fan assembled and installed by
a licensed electrician for safety and warranty purposes.
Q: How many speeds does the remote control offer?
A: The remote control provides 6 different speed settings for
customized comfort levels.
“`
BAYSIDE
STROLL
DC CEILING FAN
INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION
CAUTION
READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION.
V1.0-AU (05/2024)
STROLL DC Fan Installation Instructions
THANK YOU FOR PURCHASING
Thank you for purchasing the latest in energy saving ceiling fans. This fan
runs on DC (direct current) power which gives it the benefit of being super
energy efficient whilst still maintaining high volume air-movement and silent
operation. Energy saving – The DC motor is the latest technology in fan
design. Its highly efficient motor saves up to 65% more energy than ceiling
fans with traditional AC motors. Silent operation This DC fan motor is
programmed with a stabilised current which efficiently reduces motor noise.
Low operating temperature The DC power is managed effectively which brings
down the motor operating temperature to less than 50. This results in a much
cooler motor than a standard AC fan and increases the longevity of the motor.
6 speed remote control – Regular AC ceiling fans usually come with only 3
speeds, this DC fan comes complete with a 6 speed remote, which gives a
greater choice of comfort levels.
SAFETY PRECAUTIONS 1. The appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have
been given supervision or instruction concerning the use of the appliance by a
person responsible for their safety. 2. Children should be supervised to
ensure that they do not play with the appliance. 3. An all-pole disconnection
switch must be incorporated into the fixed wiring, in accordance with local
wiring rules.
IN AUSTRALIA
WARNING:
FOR SAFE USE OF THIS FAN AN ALL-POLE DISCONNECTION
MUST BE INCORPORATED INTO THE FIXED WIRING IN
ACCORDANCE WITH THE WIRING RULES.
As outline in clause 7.12.2 of AS/NZS 60335-1 for meeting the minimum
electrical safety of this standard.
Please note warranty will be void if installation is without a means for an
all-pole disconnection incorporated in the fixed wiring in accordance with
1 |Page
STROLL DC Fan Installation Instructions
the wiring rules. Example: If a fan is connected to a circuit that can be
isolated via an all-pole safety switch at the switchboard, then this is
considered to be an all-pole disconnection to the ceiling fan electrical
circuit, meeting the requirements of clause 7.12.2 of AS/NZS 60335.1. A
single-pole switch on the active of the receiver input of remote control must
also be included in the wiring, and located the same room as the ceiling fan.
Do not dispose of electrical appliances, remote or batteries as unsorted municipal waste, use
separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the ground water and get into the food chain, damaging your health and well-being. 5. The structure to which the fan is to be mounted must be capable of supporting a weight of 25 kg. 6. The fan should be mounted so that the blades are more than 2.1 m above the floor . 7. This fan is suitable for indoor, alfresco and coastal areas where the fan is fully undercover with a minimum of 1 wall. This fan is not waterproof. When installed in an alfresco or coastal area, the ceiling fan must be positioned in a location protected from water, wind and dust. Exposure to these elements will void the warranty. Mounting the fan in a situation where it is subject to water or moisture is dangerous and may increase the risk of damage, injury or electrical shock and will void the warranty.
8. Must be assembled and installed by a licensed electrician. 9. WARNING: If
unusual wobbling or oscillating movement is observed, immediately stop using
the ceiling
fan and contact the manufacturer, its service agent or suitably qualified
persons. 10. The replacement of parts of the safety suspension system device
shall be performed by the
manufacturer, its service agent or suitably qualified persons. 11. The fixing
means for attachment to the ceiling such as hooks or other devices shall be
fixed with a
sufficient strength to withstand 4 times the weight of the ceiling fan; that
the mounting of the suspension system shall be performed by the manufacturer,
its service agent or suitably qualified persons. 12. The light source of this
luminaire is not replaceable; when the light source reaches its end of life,
the whole luminaire shall be replaced. There are no serviceable parts, do not
attempt to dismantle or open the product.
2 |Page
STROLL DC Fan Installation Instructions
PARTS LIST · Unpack your ceiling fan carefully. Remove all parts and hardware.
· Lay out all the components on a smooth surface and make sure there are no
components missing before
assembling. If parts are missing, return the complete product to the place of
purchase for inspection or replacement. · Check whether the ceiling fan has
been damaged during transport. Do not operate/install any product which
appears damaged in any way. Return the complete product to the place of
purchase for inspection, repair or replacement. · Examine all parts, you
should have the following list and Fig.1 :
1. Mounting bracket x1 2. Canopy x 1 3. Down rod with ball joint x 1
4. Bolt and pin cover x 1
3 |Page
Fig. 1
5. Fan assembly x 1 6. Mounting bracket screws x 4pcs 7. Light kit extension
cable x1pcs
Motor extension cable x1pcs (For use with extension down rod) 8. Remote
receiver and Remote controller, screw, battery, holder x 1 set
STROLL DC Fan Installation Instructions
INSTALLING THE FAN TOOLS REQUIRED:
– Phillips / flat head screwdriver – Pair of pliers – Adjustable spanner –
Step ladder – Wire cutter – Wiring, supply cable as required by local
provincial and national wiring codes and regulations INSTALLING THE MOUNTING
BRACKET · The ceiling fan must be installed in a location so that the blades
are spaced 300mm from the tip of the blade to the nearest objects or walls. ·
Install the hanging bracket to the ceiling joist or structure that is capable
of carrying a load of at least 25kg, with four long screws provided. Ensure at
least 30mm of the screw is threaded into the support. (Fig. 2)
25 KG
Fig. 2
NOTE: The bracket screws provided are for use with wooden structures only. For
structures other than wood, the appropriate screw type MUST be used. Ensure
the screws used are suitable for the mounting surface and the surrounding
environment.
ANGLED CEILING INSTALLATION This fan hanging system supports a maximum 13
degree angled ceiling installation. (Fig. 3)
13°
Fig. 3
4 |Page
STROLL DC Fan Installation Instructions
INSTALLING THE FAN INSTALLING THE DOWN ROD (Fig. 4)
Fig. 4.1
1. Remove the ball joint (2) and dowel pin (3) by loosening the set screws
(4) from the down rod (6). Remove the hitch pin (9) by removing the lock clip
(10) (Fig. 4.1). NOTE: Do not discard keep these parts, they are required to
reassemble later.
Fig. 4.2
Fig. 4.3
Fig. 4.4
2. Loosen the set screws (11) on the down rod coupling housing (8). (Fig.
4.2) 3. Carefully feed the fan wires (1) up through the down rod (6). (fig.
4.3) 4. Assemble the down rod (6) into the down rod coupling housing (8), by
inserting and line up the down rod coupling housing holes with the down rod
holes and insert the hitch pin (9) and secure with the lock clip (10). (Fig.
4.3)
5 |Page
STROLL DC Fan Installation Instructions
5. Secure the down rod (6) by tightening the set screws (11). (Fig. 4.4)
Fig. 4.5
Fig. 4.6
6. Insert the Bolt and pin cover (7) onto the down rod (6) to cover the down rod coupling housing (8). (Fig. 4.5) 7. Insert the canopy (5) over the down rod (6) and install the ball joint (2) and dowel pin (3) back onto the down rod (6) and secure by tightening the set screws (4). (Fig. 4.5 and Fig. 4.6)
HANGING THE FAN Lift the fan assembly onto the mounting bracket. Ensure the key slot (A) of the hanger ball is positioned on the key pin (B) of the mounting bracket (C) to prevent the fan from rotating when in operation. (Fig. 5)
6 |Page
Fig. 5
STROLL DC Fan Installation Instructions
ELECTRICAL WIRING DIAGRAM THE FAN PREPARE AND COMPLETE THE ELECTRICAL WIRING —
WIRING DIAGRAM (FIG. 6) WARNING: FOR YOUR SAFETY ALL ELECTRICAL CONNECTIONS
MUST BE UNDERTAKEN BY A LICENSED ELECTRICIAN. NOTE: AN ADDITIONAL ALL POLE
DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED WIRING. NOTE: IF THERE ARE
TWO OR MORE DC CEILING FANS INSTALLED IN THE ONE LOCATION, AN ISOLATION SWITCH
IS REQUIRED FOR EACH CEILING FAN. THIS IS REQUIRED WHEN PROGRAMMING THE REMOTE
AND RECEIVER TO PAIR TOGETHER. From mains supply to mounting bracket terminal
block: (Fig. 6) 1. Connect the live supply wire to the “L” terminal of the
terminal block on the mounting bracket. 2. Connect the neutral supply wire to
“N” terminal of the terminal block on the mounting bracket.
3. Connect earth wire to the ” ” of the terminal block on the mounting
bracket.
From mounting bracket to receiver and motor: (Fig. 6) 4. Insert the supply
wiring quick connector (A) from the mounting bracket to the fan receiver. 5.
Insert the input wires quick connector (B) from the fan assembly into the fan
receiver. 6. Connect the input wires quick connector (C) from the fan assembly
into the fan receiver.
Fig. 6
Carefully insert the Remote Receiver above the hanger ball in the remainder
spacing in the mounting bracket. Take care not to damage or loosen any of the
wiring. (Fig. 7).
7 |Page
Fig. 7
STROLL DC Fan Installation Instructions
FINISHING THE INSTALLATION · After completing the electrical connection at the
mounting bracket terminal block, connect the ceiling fan
wiring via the quick connector plug.
INSTALLATION OF THE CANOPY 1. Loosen the 2 screws at the bottom of the
mouthing bracket. (Fig.8) 2. Slide the canopy up to the mounting bracket and
align the key holes on the canopy with the screws on the
mounting bracket. Turn the canopy until it locks into place with the narrow
section of the key holes and secure it by tightening the two screws. Avoid
damaging the electrical wiring prepared previously. (Fig.10)
Fig. 8
INSTALLATION OF THE REMOTE CONTROL HOLDER 1. Locate a suitable wall to fix the
remote control holder with the 2 screws & 2 anchors . (Fig.9a). 2. Slide the
remote into the holder to rest the remote. (Fig. 9b)
8 |Page
Fig. 9a
Fig. 9b
STROLL DC Fan Installation Instructions
USING YOUR CEILING FAN REMOTE CONTROL
1. Open the battery compartment cover by removing the securing screw and
insert 2 x AAA battery. Note the correct battery polarity (+/-) when inserting
the battery, and then replace the cover and secure with the screw.
2. Test the remote by pressing and hold any button. A r LED will be lit up at
the top of the remote to indicate that there is power to the remote and it is
ready for use to control the fan.
3. Follow the guide below to operate the fan and learn the functions.
(Fig.10)
Direction of the fan (reverse switch)
Speed of the fan There are 6 available speeds. “1” button is for the lowest speed, and “6” button is for the highest speed. NOTE: when you turn on the fan for the first time or switch the main power to the controller, you need to start the fan on high “6” speed first and then choose a lower speed. A 5-10 seconds is required to allow the DC fan to respond to the remote each speed or fan direction selection.
ON/OFF the fan
Timing control of the fan (1 hour, 4 hours, 8 hours)
ON/OFF the light
Turn down the brightness of the light Turn up the brightness of the light
Fig. 10
Change the color of the light (2700K 4000K 5700K)
The remote has memory function. If the fan or light is turned off by the isolating switch over 7 seconds, the next time to turn on the fan or light will be on last setting
THE FAN RECEIVER & REMOTE PAIRING NOTE: The pairing of the remote and receiver
has been done at the factory.
When the ceiling fan is installed, pairing the fan receiver and remote is NOT
required.
9 |Page
STROLL DC Fan Installation Instructions
Reverse function Your ceiling fan can operate either in fan (summer) mode or
reverse fan (winter) mode. Use the ” ” button on the remote to switch between
summer and winter mode. Summer mode: The fan will rotate in an anticlockwise
direction. The airflow will be directed downwards, for cooling in summer.
Winter mode: The fan will rotate in a clockwise direction. The airflow will be
directed upwards, for energy conservation, ensuring an even temperature
throughout your room during winter.
Fig. 11
REPAIRING THE FAN RECEIVER & REMOTE PAIRING Note: The remote and receiver have
already been paired during manufacturing. The following steps are only
necessary if remote and fan become unpaired or if pairing multiple fans.
Should the remote and receiver lose control after installation or during use,
the pairing of the remote and the receiver must be repaired. Below are the
operating symptoms and method to repair the pairing of the DC ceiling fan
remote and receiver. Symptoms: · Loss of control – Fan is only running at high
speed after installation · Loss of control – No reverse function after
installation · Loss of control – Remote cannot communicate with the receiver
Repairing Steps: · Switch OFF the main power to the ceiling fan at least 1
minute. · Switch on the main power to the ceiling fan. Press and hold the ” ”
button on the remote for 5
seconds within 30 seconds after switching on. There will be a notification
`beep’ sound from the receiver to indicate that the paring process is
successful. · Turn on and select the different speed of the ceiling fan to
check the operation of the fan.
10 | P a g e
STROLL DC Fan Installation Instructions
AFTER INSTALLATION
NOTE: Ceiling fans tend to move during operation due to the fact that they are
mounted on a rubber grommet. If the fan was mounted rigidly to the ceiling it
would cause excessive vibration. Movement of a few centimetres is quite
acceptable and DOES NOT suggest any problem.
TO REDUCE THE FAN WOBBLE: Please check that all screws which fix the mounting
bracket and down rod are secure.
NOISE: When it is quiet (especially at night) you may hear occasional small
noises. Slight power fluctuations and frequency signals superimposed in the
electricity for off-peak hot water control, may cause a change in fan motor
noise. This is normal. Please allow a 24-hour “settling-in” period, most
noises associated with a new fan disappear during this time. The
manufacturer’s warranty covers actual faults that may develop and NOT minor
complaints such as hearing the motor run All electric motors are audible to
some extent.
CARE & CLEANING
NOTE: Always turn OFF the power at the mains switch before performing any
maintenance or attempting to clean your fan.
· Every 6 months periodic cleaning of your ceiling fan is the only maintenance
required. Use a soft brush or lint free cloth to avoid scratching the paint
finish. Please turn off electricity power when you do so.
· Do not soak or immerse your ceiling fan in the water or other liquids. It
could damage the motor or the blades and create the possibility of an
electrical shock.
· Ensure that the fan does not come in contact with any organic solvents or
cleaners. · To clean the fan blade, wipe with only a damp clean cloth with NO
organic solvents or cleaners. · The motor has a permanently lubricated ball
bearing so there is no need to oil. · The light source of this luminaire is
not replaceable; when the light source reaches its end of life, the
whole luminaire shall be replaced. There are no serviceable parts, do not
attempt to dismantle or open the product.
SAFETY PRECAUTIONS FOR BATTERY – WARNING Keep new and used batteries away
from children. – CAUTION Do not ingest battery–Chemical burn hazard. –
Always use 2 x AAA battery type with this ceiling fan remote controller. –
Ensure the batteries are inserted with the correct polarity. – To prevent
false operation during battery insertion or replacement, this ceiling fan must
be disconnected
from the supply mains. – non-rechargeable batteries are not to be recharged; –
different types of batteries or new and used batteries are not to be mixed; –
Remove batteries from the product when not in use for long periods of time.
11 | P a g e
STROLL DC Fan Installation Instructions
– Batteries must be removed from the remote transmitter before it is
discarded. – Dispose of exhausted batteries immediately and safely (so they
cannot be retrieved by children).
Batteries can still be dangerous. Contact your local council to safely dispose
of the battery. – Regularly check the product and make sure the battery box
lid is correctly secured. If the battery
compartment does not close securely, stop using the product and keep it away
from children. – If you think batteries might have been swallowed or placed
inside any part of the body, seek immediate
medical attention. If you suspect your child has swallowed or inserted a
button battery, immediately call the 24-hour Poisons Information Centre on 13
11 26 for fast, expert advice. – Battery Leaks: Battery contains chemicals and
should be treated as any chemical would. Take precautions when handling leaked
battery chemicals. Battery chemicals should not be placed near the eyes or
ingested. Contact Poisons Information Centre on 13 11 26 for fast, expert
advice.
Fan Fan Models Rated Voltage Rated Wattage (Motor)
Rated wattage (Lamp)
Battery for remote Weight Canopy Dimensions
TECHNICAL INFORMATION 42” STROLL DC fan SKU# 216129 220-240V~ 50Hz
30W LED 33W, 2700K 3200 lumens 4000K 3300 lumens 5700K 3500 lumens 2 x
AAA (Included)
6.4kg
H:55mm Dia:148mm
12 | P a g e
STROLL DC Fan Installation Instructions
BAYSIDE CEILING FAN WARRANTY DETAIL
BAYSIDE WARRANTY HOTLINE – 1300 289 808
THIS WARRANTY IS VALID IN AUSTRALIA ONLY
In the event of service being required, please call the Bayside Fan Warranty
Hotline on 1300 289 808 between 9am & 5pm (EST) Monday to Friday. Please make
sure you have all the ceiling fan details filled out at the end of the manual
before making the call.
Every Bayside ceiling fan is thoroughly inspected and tested before being
released for sale. In addition to any warranty rights or conditions under
statutory regulations, Bayside warrants all of its ceiling fans against
defective workmanship and faulty materials with an in-home warranty period of
twenty four (24) months from the date of purchase. Following this, an
additional fourty eight months (48) part replacement warranty applies.
Bayside undertakes, at its option, to repair or replace, free of charge, each
product or part thereof on condition that;
1. The fan or relevant part has not been subjected to misuse, neglect, or
been involved in an accident. 2. The repairs are not required as a result of
normal wear and tear. 3. The product was installed by a licensed electrical
contractor. 4. A copy of the original receipt of purchase is presented. 5. 12
month warranty applies when used in any non-domestic applications. 6. This
warranty does not cover stains, scratch and scuff marks, or dents if the
product is purchased
through a factory outlet or to refurbished items.
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure
and compensation for any other reasonably foreseeable loss or damage. You are
also entitled to have the goods repaired or replaced if the goods fail to be
of acceptable quality and the failure does not amount to a major failure.
Bayside design cannot be held responsible for any repair other than those
carried out by it or one of its Authorised Service Agents. Please keep this
warranty information in a safe place. This information must be produced in the
event of service being required.
Distributed by: Bayside Fans and Lighting 140 Fulton Drive, Derrimut 3026,
Victoria, Australia Ph: 1300 289 808 Email:
warranty@baysidefansandlighting.com.au
13 | P a g e
STROLL DC Fan Installation Instructions
CEILING FAN WARRANTY INFORMATION
BAYSIDE WARRANTY HOTLINE – 1300 289 808
Complete and retain this form for your personal records and warranty purposes.
NAME………………………………………………………………………………… ADDRESS……………………………………………………………………………
……………………………………………………POSTCODE…………………… MODEL NUMBER……………………………………………………………………
(PO# + DATECODE Sticker here) PO NUMBER or DATECODE ……………………………………………………… DATE
OF PURCHASE……………………………………………………………… INSTALLING LICENSED
ELECTRICAN…………………………………………… ………………………………………………………………………………………… LICENCE
No………………………………………………………………………… ATTACH PROOF OF PURCHASE HERE
14 | P a g e
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>