Important Information

Ecodesign Regulation (EU) 2015/1188 concerning local space heaters does not apply to all application areas. The Regulation applies when an installation is intended to provide thermal comfort for people in the premises. The Regulation does not apply to heating installations of a more technical nature e.g. in engineering/utility rooms, in production processes, frost protection, etc. The Regulation also does not apply to installations in vehicles, offshore or outdoors. Many of Frico’s products can be used as both local space heaters (as defined in (EU) 2015/1188) and for technical heating purposes. It is up to the installer responsible for the installation to assess whether the Ecodesign Regulation is applicable or not. Control solutions for installations not covered by the Ecodesign Regulation are listed in a separate table.

Dimension

Type L1 [mm] L2 [mm]
IR3000 600 1125
IR4500 900 1500
IR6000 1200 1875

Dimension

Minimum distances

Minimum distances

| | [mm]
---|---|---
Ceiling| A| 400
Wall, long side of the unit| B| 400
Wall, short side of the unit| C| 400
Flammable material| D| 700
Floor| E| 2300

Minimum distances

Accessories

Type HxWxD [mm]
IRG3000 869x362x40
IRG4500 1235x362x40
IRG6000 1615x362x40

Accessories

Controls

Type HxWxD [mm]
TAP16R 87x87x53
TEP44 87x87x55
RB3 155x87x43
RB123 155x87x43
RTX54 82x88x25
SKG30 115x85x40
PDK65 102x70x50

Controls

Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188

Type HxWxD [mm]
KRT1900 165x57x60
KRTV19 165x57x60
S123 72x64x46

Controls

Technical specifications

Type| Output steps [kW]| Voltage [V]| Amperage [A]| Max. element temperature [°C]| Dimensions LxHxW [mm]| Weight [kg]
---|---|---|---|---|---|---
IR3000| 1/2/3| 400V3N~| 4,3| 700| 1125x83x358| 9.0
IR4500| 1.5/3/4.5| 400V3N~
| 6,5| 700| 1500x83x358| 11.1
IR6000| 2/4/6| 400V3N~*| 8,7| 700| 1875x83x358| 13.2

*) Can also be connected 400V3~, but then without output steps. With neutral, one element tube at a time can be connected.

Protection class: IP44.
CE compliant.

Wiring diagrams

  • Internal wiring diagram
    Wiring diagrams

  • Control by thermostat and relaybox
    Wiring diagrams

  • Control by thermostat, relaybox and black bulb sensor
    Wiring diagrams

  • Control by relaybox with 3 step output control and presence detector
    Wiring diagrams

  • Control by thermostat, contactor and switch – for installations not covered by the Ecodesign Regulation (EU) 2015/1188
    Wiring diagrams

ATTENTION Some device parts can become very hot and burns cause. In the presence of children or frail people is special Be careful.

Customer Support

Main office
Frico AB Tel: +46 31 336 86 00
Industrivägen 41
SE-433 61 Sävedalen mailbox@frico.se
Sweden www.frico.net
For latest updated information and information about your local contact: www.frico.net

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals