FRICO IR Series Infrared Heater Industrial Heater Instruction Manual
- June 13, 2024
- FRICO
Table of Contents
FRICO IR Series Infrared Heater Industrial Heater
Important Information
Ecodesign Regulation (EU) 2015/1188 concerning local space heaters does not apply to all application areas. The Regulation applies when an installation is intended to provide thermal comfort for people in the premises. The Regulation does not apply to heating installations of a more technical nature e.g. in engineering/utility rooms, in production processes, frost protection, etc. The Regulation also does not apply to installations in vehicles, offshore or outdoors. Many of Frico’s products can be used as both local space heaters (as defined in (EU) 2015/1188) and for technical heating purposes. It is up to the installer responsible for the installation to assess whether the Ecodesign Regulation is applicable or not. Control solutions for installations not covered by the Ecodesign Regulation are listed in a separate table.
Dimension
Type | L1 [mm] | L2 [mm] |
---|---|---|
IR3000 | 600 | 1125 |
IR4500 | 900 | 1500 |
IR6000 | 1200 | 1875 |
Minimum distances
| | [mm]
---|---|---
Ceiling| A| 400
Wall, long side of the unit| B| 400
Wall, short side of the unit| C| 400
Flammable material| D| 700
Floor| E| 2300
Accessories
Type | HxWxD [mm] |
---|---|
IRG3000 | 869x362x40 |
IRG4500 | 1235x362x40 |
IRG6000 | 1615x362x40 |
Controls
Type | HxWxD [mm] |
---|---|
TAP16R | 87x87x53 |
TEP44 | 87x87x55 |
RB3 | 155x87x43 |
RB123 | 155x87x43 |
RTX54 | 82x88x25 |
SKG30 | 115x85x40 |
PDK65 | 102x70x50 |
Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188
Type | HxWxD [mm] |
---|---|
KRT1900 | 165x57x60 |
KRTV19 | 165x57x60 |
S123 | 72x64x46 |
Technical specifications
Type| Output steps [kW]| Voltage [V]| Amperage [A]| Max. element temperature
[°C]| Dimensions LxHxW [mm]| Weight [kg]
---|---|---|---|---|---|---
IR3000| 1/2/3| 400V3N~| 4,3| 700| 1125x83x358| 9.0
IR4500| 1.5/3/4.5| 400V3N~| 6,5| 700| 1500x83x358| 11.1
IR6000| 2/4/6| 400V3N~*| 8,7| 700| 1875x83x358| 13.2
*) Can also be connected 400V3~, but then without output steps. With neutral, one element tube at a time can be connected.
Protection class: IP44.
CE compliant.
Wiring diagrams
-
Internal wiring diagram
-
Control by thermostat and relaybox
-
Control by thermostat, relaybox and black bulb sensor
-
Control by relaybox with 3 step output control and presence detector
-
Control by thermostat, contactor and switch – for installations not covered by the Ecodesign Regulation (EU) 2015/1188
ATTENTION Some device parts can become very hot and burns cause. In the presence of children or frail people is special Be careful.
Customer Support
Main office
Frico AB Tel: +46 31 336 86 00
Industrivägen 41
SE-433 61 Sävedalen mailbox@frico.se
Sweden www.frico.net
For latest updated information and information about your local contact:
www.frico.net
References
Read User Manual Online (PDF format)