MEAN WELL LRS-50 Series Single Output Switching Power Supply Owner’s Manual
- June 10, 2024
- MEAN WELL
Table of Contents
MEAN WELL LRS-50 Series Single Output Switching Power Supply Owner’s Manual
Features
- Universal AC input / Full range
- Withstand 300VAC surge input for 5 second
- No load power consumption<0.3W
- Miniature size and 1U low profile
- High operating temperature up to 70℃
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Compliance to IEC/BS EN/EN 60335-1(PD3) and IEC/BS EN/EN61558-1, -2-16 for household appliances
- Operating altitude up to 5000 meters (Note.8)
- Withstand 5G vibration test
- High efficiency, long life and high reliability
- LED indicator for power on
- Over voltage category Ⅲ
- 100% full load burn-in test
- 3 years warranty
Description
LRS-50 series is a 50W single-output enclosed type power supply with 30mm of low profile design. Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 3.3V, 5V, 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 90%, the design of metallic mesh case enhances the heat dissipation of LRS-50 that the whole series operates from -30℃ through 70℃ under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.2W), it allows the end system to easily meet the worldwide energy requirement. LRS-50 has the complete protection functions and 5G antivibration capability; it is complied with the international safety regulations such as TUV BS EN/EN62368-1, BS EN/EN60335-1,BS EN/EN61558-1/-2-16, UL62368-1 and GB4943. LRS-50 series serves as a high price- to- performance power supply solution for various industrial applications.
Model Encoding
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- Household appliances
GTlN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL| LRS-50-3.3| LRS-50-5| LRS-50-12| LRS-50-15|
LRS-50-24| LRS-50-36| LRS-50-48
---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V| 36V| 48V
RATED CURRENT| 10A| 10A| 4.2A| 3.4A| 2.2A| 1.45A| 1.1A
CURRENT RANGE| 0 ~ 10A| 0 ~ 10A| 0 ~ 4.2A| 0 ~ 3.4A| 0 ~ 2.2A| 0 ~
1.45A| 0 ~ 1.1A
RATED POWER| 33W| 50W| 50.4W| 51W| 52.8W| 52.2W| 52.8W
RIPPLE & NOISE (max.) Note.2| 80mVp-p| 80mVp-p| 120mVp-p| 120mVp-p|
150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 2.97 ~ 3.6V| 4.5 ~ 5.5V| 10.2 ~ 13.8V| 13.5 ~ 18V|
21.6 ~ 28.8V| 32.4 ~ 39.6V| 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%
LINE REGULATION Note.4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%|
±0.5%
LOAD REGULATION Note.5| ±2.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%|
±0.5%
SETUP, RISE TIME| 1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full
load
HOLD UP TIME (Typ.)| 30ms/230VAC 12ms/115VAC at full load
INPUT| VOLTAGE RANGE| 85 ~ 264VAC 120 ~ 373VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 80%| 83%| 86%| 88%| 88%| 89%| 90%
AC CURRENT (Typ.)| 0.95A/115VAC 0.56A/230VAC
INRUSH CURRENT (Typ.)| COLD START 45A/230VAC
LEAKAGE CURRENT| <0.75mA / 240VAC
PROTECTION| OVER LOAD| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE| 3.8 ~ 4.45V| 5.9~ 7.3V| 13.8 ~ 17.2V| 18.75 ~ 25.75V| 28.8
~ 36.6V| 41.4 ~ 51.6V| 55.2 ~ 67.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS
EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters
SAFETY & EMC (Note 9)| **SAFETY STANDARDS| UL62368-1, TUV BS
EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,CCC GB4943.1, BSMI
CNS15598-1, EAC TP TC 004, AS/NZS 60950.1(by CB),KC K60950-1(for LRS-50-12/24
only),BIS IS13252(Part1): 2010/IEC 60950-1: 2005(except for LRS-50-48)
approved
WITHSTAND VOLTAGE| I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN55014, BS EN/EN61000-3-2,-3, GB/T 9254, BSMI CNS15936, EAC TP TC 020,KC
KN32,KN35(for LRS-50-12/24 only)
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035,heavy industry level, EAC TP TC
020,KC KN32,KN35(for LRS-50-12/24 only)
OTHERS| MTBF| 3149.8K hrs min.
Telcordia SR-332 (Bellcore) ; 561.6Khrs min. MIL-HDBK-217F (25℃)
DIMENSION| 998230mm (LWH)
PACKING| 0.23Kg; 60pcs/14.8Kg/0.88CUFT
NOTE**|
-
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
-
Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
-
Tolerance : includes set up tolerance, line regulation and load regulation.
-
Line regulation is measured from low line to high line at rated load
-
Load regulation is measured from 0% to 100% rated load
-
Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
-
3.3V,5V when the load factor 0~50%, the switching power less is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications.
-
8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).
-
The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness.
The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.(as available on http://www.meanwell.com)- Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
Block Diagram
fosc : 115Vac : 75KHz
230Vac :110KHz
Derating Curve
Static Characteristics
Mechanical Specification
Terminal Pin No. Assignment
Pin No. | Assignment | Pin No. | Assignment |
---|---|---|---|
1 | AC/L | 4 | DC OUTPUT –V |
2 | AC/N | 5 | DC OUTPUT +V |
3 | FG |
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>