BLUE JAY MICO-RACE Wireless Temperature Monitor
User Manual: MICO-RACE Wireless Temperature Monitor
Product Information
The MICO-RACE wireless temperature monitor is a device that allows you to monitor temperature wirelessly. It comes with a remote sensor, MRS, that should be installed within a distance of 100m outside or 20m inside a room without any electromagnetic shielding layer. The device has an Ethernet port for TCP/IP communication and is available in two versions: standard MRR-E and advanced MRR-ED. The MRR-E requires a 6~34VDC power supply and comes with a 12VDC 1A adapter, while the MRR-ED supports DHCP function.
Product Usage Instructions
Before using the MICO-RACE wireless temperature monitor, it is important to read the user manual carefully and follow the instructions for correct guidance of operations. Here are some guidelines to follow:
- Ensure that the power supply for the MRR receiver is within the provisions of the instrument before turning on the power supply.
- Make sure that the MRR wiring is consistent with the label marked.
- Install the MRS remote sensor at a standard distance between the sensor and receiver without any electromagnetic shielding layer.
- Do not impose the communication port (RS232/RS485 or Ethernet) on high pressure.
- If commissioning on PC, use a series port (RS232/RS485) or serial port simulation tools for conversion.
For MRR-E, follow these additional instructions:
- Use an Ethernet connection for communication.
- Ensure that the MRR-E device body is in a cool and well-ventilated place as the Ethernet chip will emit some heat while working.
- Follow the step-by-step guide for initial configuration.
Please read the user manual carefully and save it for future reference. For any technical assistance, contact Blue Jay Technology by email at tech@cqbluejay.com or call at +0086-023-67628702.
Read me
When you use MICO-RACE wireless temperature monitor, be sure to read this user
manual carefully, and be able to fully understand the implications, the
correct guidance of operations in accordance with user manual, which will help
you make best use of MICO-RACE wireless temperature monitor, and help to solve
the various problems at the scene.
- Before the MRR receiver turning on the power supply, be sure that the power supply within the provisions of the instrument;
- Be sure the MRR wiring consistent with the label marked;
- MRS remote sensor must be installed in standard distance(less than 100m outside and less than 20m in room), between sensor and receiver without electromagnetic shielding layer;
- Communication port (RS232/RS485 or Ethernet) is strictly prohibited to impose on high pressure;
- When commissioning on PC, please make sure use series port(RS232/RS485), or use serial port simulation tools for conversion.
- Please read this user manual carefully
- Please save this document
Guide for MRR-E and software operation
MRR-E wiring
Mico-Race data receiver MRR-E standard use RJ45 port(Ethernet connection)
and 6~34VDC power supply;
Blue Jay Technology standard provide 12VDC 1A adapter.
| MRR- E
---|---
Pictures|
Notes:
Ethernet chip will emits some of heat in working, please make sure MRR-E
device body in cool and well-ventilated place!
Package list:
MRR- E
MRR-E device 1
12VDC 1A adapter 1
1.5m 433Mhz Antenna *1
MRR-E configuration
MRR-E has a built-in Ethernet chip for TCP/IP communication, and there have
two version of MRR-E, standard MRR-E do not support DHCP, advanced MRR-ED type
with DHCP function, please follow the guide step for initial configuration:
- Close the firewall of your computer system.
- Please disable the excess NIC(Network Interface Card) in your PC or wireless NIC inyour laptop, leave only one physical NIC connected to MRR.
- 3: Connect the MRR-E to the Ethernet Router and power ON; please make sure your PC in same network.
- 4: Use the configuration software TCP232-E45_V1.4.2(DHCP types) or TCP232-T24_V5.1.0.1(Standard types) for initial configuration
Ethernet chip had done the initial setting, default parameter as following:
- Module IP: 192.168.0.7
- Subnet mask: 255.255.255.0
- Default Gateway: 192.168.0.1
- Destination IP: 192.168.0.2
- Destination Port: 16254
Part I: Ethernet Port configuration in MRR-E
Use [TCP232-T24-V5.1.0.1]
- Step 1: Run [USR-TCP232-T24 V5.1.0.1.exe] in your PC, press button Search in LAN, software will auto scan your network to find MRR-E device, device shown in right box:
- Step 2: Double click the searched device can read the configuration parameters in left chart:
- Step 3: Please change the following configuration:
Module IP :| Assign the MRR-E device IP to any one you like in your sub- network, do not duplicate existing equipment, otherwise there will be a network error.
---|---
Default Gateway :| Change Gateway IP that matched with your network setting.
Notes: if you purchase DHCP type please see Part II
Destination IP
Destination port
| Change the IP and TCP port that direction to your PC run [ Microtemp ]
Notes: Please do not change other parameter in Ethernet Port, or MRR-E may unable to work.
- Step4: Press button Set selected item via LAN to end the Set
Part II: Ethernet Port configuration in MRR-ED
Use [TCP232-E45_V1.4.2]
- Step1- Press Search Device button for auto find the MRR device
- Step2- Choose the MRR device in lists, software will update the device configuration info
- Step3- If MRR-E connects to router, you can choose DHCP mode, please make sure your router can assign IP; if connected directly to host PC, please chose Static IP mode, and configuration the MRR Ethernet gateway & IP address related your host PC setting.
Note: Only Port0 is available, and do not change other parameter in Ethernet Port, or MRR-E may unable to work.
Please do not change the Baud rate(9600)or MRR will not work
How to use Microtemp Desktop
Blue Jay Technology provide standard local software “Microtemp.exe” for MRS
sensor setting and test operation, it provide MRS parameter configuration and
basic monitor & record on your Desktop PC, please follow the guide to start.
Notes: Software only have Chinese character, if the software displayed
shows garbled code, please install the windows Chinese Language Pack.
Run “Microtemp.exe” to show temperature data from MRS in your PC
- Step 1: Set communication parameter
Click COMM Config, software will automatic detect LAN IP of your PC and show in the dialog window, please make sure the IP same as preset “Destination IP” in Chart 1.2.1 or Chart 1.2.2, then input the preset ” Destination port” (in example we use default is 16254), after that click OK:
- Step 2: Add MRS sensor
Click Add MRS, you can add MRS sensor in record list, please make sure your MRS types, and input the ID on the MRS label, then click sensor added: OK; repeat this step until all the MRS
- Step 3: Start operation
Click RUN in toolbar, then switch to “Raw_data” page, you should see a upload command, it contain MRR ID inside, mean connection success. Otherwise, the connection is unsuccessful, please check the connection of MRR-E or configuration in Chart 1.2.1 or Chart 1.2.2:
- Step 4: basic configuration
In “Curve” page, click each MRS line, you can see record curve drawn by latest 10 record point. also you can see the “Basic Config” table in the right part of screen. detail of each parameter please refer to the ” Mico Race Data Format_1.6 “
in example show setting of MRS (000075B6):
Choose any parameter you want to know in 000075B6, press Read, you can see the
data in “value” column; Double-click column can input the setting value, then
press Set.
In configuration operation, after set one MRS, you can switch to the
“Raw_Data” screen to see detail data flow, that can easy help test engineer
understand MICO-RACE protocol.
- Step 5: Advanced configuration
In [Config View] in toolbar, you can change the operation screen in “MRS Advanced Config” or “MRR Advanced Config” page:
Notes: we do not suggest client change the advance configuration, if operation step wrong, may cause MICO-RACE disable erro; please contact Blue Jay Tech Team for more support —tech@cqbluejay.com—
If you understand the operation step and accept this risk, input password “00000000” for entry the advanced configuration page:
detail meaning of each parameter please refer to the ” Mico Race Data
Format_1.6 ”
Notes: in Forest Network (FN), if you want add other MRS in existed MRR
group, just configuration “Update ID” same as this existed MRR, you can do
this work from any MRR device.
Other function:
-
Save MRS list, click [Save] on tool bar, you can save the MRS list in “Microtemp”. Next time you can press [Open] to load the MRS list and continue work.
-
Cancel MRS in your list, select the MRS you want to delete. (need switch to “Curve” page), Click Cancel MRS on the toolbar.
-
MRS record value, Software will record the latest 100 data in “History” page for each listed MRS, you can press [Export] on toolbar to save the record data in Excel file.
Notes: this guide is only for standard MRS sensor. If purchase special types, some of the function parameter read/write is disable, please refer to the “Mico Race Data Format Introduction ” for more details
Guide for MRR-R
Blue Jay provide MRR-R for special client for connect third party router(RS232 or RS485 port), only communication port is different with MRR-E
MRR-R wiring
Mico-Race data receiver MRR-R standard use DB9 PIN male port(RS232/RS485) and
used 6~34VDC power supply;
Blue Jay Technology standard provide 12VDC 1A adapter (85~265VAC input), and
DB9P adapter (for MRR-R-485).
| MRR-R- 232| MRR-R- 485
---|---|---
Terminal No.| 2- RX ** / 3- TX| 6- A / 1- B
Baud ratio| 9600| 9600
Pictures| | **
Notes:
Please refer to the wiring drawing on product label!
Please use the cross-connect wire kit in package for
MRR-R-232 communicate with PC, If you use the USB adapter cable, please also
connect the cross-connect wire between adapter and MRR-R
Package list:
Tel:+0086-023-67628702
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China
MRR-R- 232 | MRR-R- 485 |
---|
MRR-R-232 device 1
RS232 cross-connect female cable 1 12VDC 1A adapter 1
1.5m 433Mhz Antenna 1| MRR-R-232 device 1 RS485 connect kit 1 12VDC 1A
adapter 1 1.5m 433Mhz Antenna 1
MRR-R configuration
MRR-R do not need special configuration, Blue Jay Tech Team had preset the
device working parameter, user can use any series port scan software to check
MRR-R connection is success.
Notes: please make sure your series port scan software use 9600 baud
ratio and send the following code to MRR
55 7A 07 82 00 01 04 00 00
if you can received the following code mean MRR-R connect well and prepared
working AA 75 0C 83 00 00 00 01 3C 00 04 01 00 00
Guide for MRR-M
MRR is special designed for MICO-RACE system, with standard MRR-R and one GPRS router inside. GPRS router support 850/900/1800/1900 frequency, GSM network, default use 900/1800 frequency.
Front Panel Description
Notes:
- Antenna have different sharp, depends one client requirement, all use standard SMA port, if antenna damaged or dissatisfied with signal performance, users can change higher gain antenna with same specification and port.
- Aux power support standard 12/24V AC-DC adapter or battery, if power less than 6V MRR-M may work abnormal.
- Pease make sure your SMS card support GPRS network (2G), if your local mobile network service providers other frequency, please contact Blue Jay Tech team
- User can use any types of RS232 adapter for configuration, or use SMS command to set basic parameter, more details please refer to Chart 3.3
System configuration- GPRS router
MRR-M communication port is RS232, you can use any type of RS232 adapter to
connect host PC, every MRR-M default setting is send data to Blue Jay Cloud
Server www.microtemper.com, if you want send
data to other IP, please follow this guide:
Step 1: Set PID switch for GSM configuration
Change the PID switch 5.6 ON, as photo shown; and connect RS232 port to your host PC.
Step 2: Open [DTU-RTU tool.exe] (You can choose 64/32bit only for PC Windows OS). Software provides English display, press button as indicate change to English.
- Change Comport to right port no. (In demo is COM5).
- Choose Baud Rate to “9600”.
- Leave other buttons do not change or set, then press Open COM button.
- Make sure SIM card in holder and powered on MRR-M.
The left screen window show welcome info as follow, mean GPRS router is connect to PC and prepare configuration.
Notes: MRR-M default set to automatic connect remote server, please do all the configuration in 30sec, that parameter setting will invalid after screen window show “CONNECTED”. in this situation only needs to repower the MRR-M.
- Step 3: Set APN (Access Point Name) info
Please contact your local mobile network service providers for confirm the APN account and password, in demo use china mobile.
After enter right APN info, press button to confirm setting, user can press button Get to check presetting in left screen window.
- Step 4: Set destination IP to remote server
MRR-M support URL or IP setting, send data to max 6 different remote IP (named from A to F). In demo use BLUE JAY cloud server(User can get a 6 month free account for testing, you can find your own Server Port and account info in products package, or contact your sale manager. more details please refer Chart 3.
After enter right Server info, press button Set to confirm setting, user can press button to check presetting in left screen window.
Notes: Please do not change other parameter in GPRS router, if you want
advanced function, please contact Blue Jay Tech Team:
tech@cqbluejay.com
After set the GPRS configuration, powered off the MRR-M, then disconnect RS232
adapter and recovery PID switch 1.4 ON, as following photo, repower the MRR-M
it will send data to the destination IP.
Remote config & check MRR-M
MRR-M support remote configuration via SMS, just need send txt message to cell
phone number inside MRR-M.
Function | SMS command | Feedback data |
---|---|---|
[GPRS IM+8 digital] | ||
Check registered situation of DTU | (07,XXX=1) | Each digital use (0/1) |
meaning as follow:
- SMS card normal
- Had registered in GSM network
- Had obtained IP address
- Had connect to GSM server
- Had received data from server
- Heartbeat opened
- Reversed
- GPRS protocol stack open
| | [AT+CSQ +CSQ:25,0]
DTU Signal strength query| AT+CSQ| ——— Signal strength 25, the value max is
31, high value mean signal is
| | better
Query DTU| | IP_A:60.191.205.75,20006
destination IP| (20,XXX=1)| ———-
and TCP port| | Only IP_A is valid
Config DTU destination IP and TCP port| (21,XXX=IP,PORT)|
Set Heartbeat| (04,XXX=HB_time,HB_text)| HB_time: Heartbeat interval,
unit in sec
HB_text: text in Heartbeat, do not over 100 characters
Set APN Username & password| (00,XXX=apn,username,password)|
Restart DTU| (06,XXX=1)|
If need send command from TCP server, command format: [ID][SMS
command]*
[SMS command] is same in above chart [ID] is DTU ID, default is 00000000
Access Blue Jay cloud software
Blue Jay Technology also provide cloud record software in English version for test use. please configure MRR-E or MRR-M send data to following IP and TCP port:
- Destination IP: 106.75.224.56
- Destination Port: 30XXX (you can find in the customer mail in package or contact our sales team)
please refer to chart 1.2.1(2) and chart 3.2 for configuration MRR direct to Blue Jay cloud server
Then open your Web Browser
Connect this site: http://106.75.224.56
User Name and Password you can find in customer mail in package
Default test account:
- username: test@cqbluejay.com
- password: 000000
Troubleshooting
Q: Why can’t I connect MRR-E or even cannot search MRR-E ?
A: please confirm you MRR-E and you host PC in same sub-section, and please
allow the TCP port in & out your host PC 1500, 2317, 16254, 27011. if possible
please close your firewall when do configuration.
Q: Why the MRS can automatically upload data, but I cannot read data from
host actively ?
A: the MRS use IPEX connector to antenna, due to vibration the connector may
lose, please open the MRS case to re-tightening the IPEX connector.
Q: I cannot connect to Blue Jay cloud server?
A: Blue Jay provide free cloud server for every client test, our engineers
will be debug and update the cloud server program from time to time, please be
patient and server can reopen in 24 hours. Any of your comment would be much
appreciated.
Tel: +0086-023-67628702
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China
Email:tech@cqbluejay.com