VELOCITY AWR Gas Fired Stainless Steel Combi Boiler User Guide

June 12, 2024
Velocity

VELOCITY logo PRODUCT SELECTION GUIDEVELOCITY AWR Gas Fired Stainless Steel
Combi Boiler Quality Value & Service

AWR Gas Fired Stainless Steel Combi Boiler

Velocity
Boiler Works
is a leader in Hydronic Heating Technologies.
Velocity
delivers Residential and Commercial Oil and Gas-Fired Cast Iron Boilers, Stainless Steel Condensing Boilers, Indirect Water Heaters, and Warm Air Oil Furnaces with the guiding principles of offering quality products with outstanding customer service at competitive pricing.

Product Notes:
The NET AHRI Steam Ratings shown are based on a Piping and Pickup Allowance of 1.333.
The NET AHRI Water Ratings shown are based on a Piping and Pickup Allowance of 1.15.
The Manufacturer should be consulted before selecting a boiler for installations having unusual Piping Pickup requirements, such as Intermittent System Operation, Extensive Piping Systems, etc.
Not all models are suitable for installation with all fuels or altitudes.
Refer to Product Specific Literature or Manual for complete details.

CONDENSING
GAS
RESIDENTIAL HEATING
WATER

COMBI II
Condensing – Direct Vent – Stainless Steel
Gas-Fired – Adaptive Combustion
Hot Water – Water TubeVELOCITY AWR Gas Fired Stainless Steel Combi
Boiler

  • 95% AFUE with 10:1 turndown ratio
  • Heat Input – 13.6 -120 MBH Input
  • Domestic Hot Water – Up to 3.7 GPM at 70 degree rise
  • Low Loss Header Included
  • Field Convertible to LP

CLICK HERE FOR MORE INFO

  • Easy access to key components
  • Fully removable front & side panels
  • Drop down control center

Space Heating Ratings| Dimensions| Domestic Hot Water (DHW) Ratings 1| Shipping Weight (lbs)
---|---|---|---
Model| Input 2 (MBH)| DOE Heating Capacity (MBH)| AHRI Net Rating 3 (MBH)|

AFUE %

| Depth (in)| Width (in)| Height (in)| Input 2 (MBH)| Hot Water Draw Limits GPM
Min| Max| Min| Max| Max| Min 4
70°F Rise| 77°F Rise| 90°F Rise
PHTM2136C| 13.6| 120| 112| 97| 95.0| 16.3| 17.8| 29.8| 13.6| 136| 3.7| 3.4| 2.9| 0.5| 112
PHTM2200C| 20| 150| 141| 123| 95.0| 20.4| 17.8| 29.8| 20| 200| 5.2| 4.7| 4.0| 0.5| 135

  1. DHW ratings are not AHRI certified.
  2. Input and DHW draw limits for elevations up to 2,000 ft. with min vent length. See Table 3-3 in installation manual for derate at max vent length.
  3. Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent operation, extensive piping systems, etc.
  4. Min DHW flow rate required through boiler to initiate DHW demand. Higher flow rate through fixture may be required due to mixing at tempering valve and/or fixture itself.

Condensing – Direct Vent – Stainless Steel
Gas-Fired – Adaptive Combustion
Hot Water – Water TubeVELOCITY AWR Gas Fired Stainless Steel Combi
Boiler

  • 95% AFUE with 10:1 Turndown
  • Four Sizes – 80, 120, 150, 180 MBH input
  • 2” venting standard
  • 5-year parts warranty
  • Field convertible to LP

CLICK HERE FOR MORE INFO

  • Easy access to key components
  • Fully removable front & side panels
  • Drop down control center

Space Heating Ratings| Dimensions and Connections| Shipping Weight (lbs)
---|---|---
Model| Input 1 (MBH)| DOE Heating Capacity (MBH)| AHRI Net Rating 2 (MBH)| AFUE| Depth (in)| Width (in)| Height (in)| Space Heating Water sweat, (in)| Gas NPT
Min| Max
PHTM2080H| 83| 80| 75| 65| 95.0| 16.3| 17.8| 29.8| 1| 1/2| 107
PHTM2120H| 13.6| 120| 112| 97| 95.0| 16.3| 17.8| 29.8| 1| 1/2| 112
PHTM2150H| 20| 150| 141| 123| 95.0| 20.4| 17.8| 29.8| 1| 1/2| 132
PHTM2180H| 20| 180| 169| 147| 95.0| 20.4| 17.8| 29.8| 1| 1/2| 132

  1. Input for elevations up to 2,000 ft. with min vent length. See Table 3-3 for vent diameter connection sizes and derate at max vent length.
  2. Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent operation, extensive piping systems, etc.
  3. For altitudes above 2,000 ft., PHNTM2080H minimum input increased to 10 MBH.

Condensing – Direct Vent – Stainless Steel
Gas-Fired – Hot Water – Water Tube

  • Two Sizes: 210-285
  • 5:1 turndown ratio
  • Up to 95% AFUE (PHNTM 210-285)
  • Stackable for floor space savings
  • Natural gas and LP applications – consult manual

SPACE HEATING RATINGS

CLICK HERE FOR MORE INFO

MODEL| MAX. INPUT
(MBH)| MIN. INPUT
(MBH)| HEATING
CAPACITY
(MBH)| NET AHRI
WATER
RATING (MBH)| AFUE
(%)| W
(IN)| D
(IN)| H
(IN)| VENT
DIAMETER
(IN)| APPROX.
SHIPPING
WEIGHT (LBS)
---|---|---|---|---|---|---|---|---|---|---
PHNTM210| 210| 42| 194| 169| 95.0| 16-11/16| 23-15/16| 32-3/16| 3| 206
PHNTM285| 285| 57| 262| 228| 95.0
| 16-11/16| 21-13/16| 43-7/16| 3| 256

Condensing – Direct Vent – Gas-Fired
Stainless Steel – Fire Tube Design – Hot Water

  • Up to 96% AFUE
  • 10:1 turndown ratio
  • Five sizes: 85-270 MBH heat only
  • 5-year parts warranty
  • Field convertible to LP gas with optional kit

SPACE HEATING RATINGS

CLICK HERE FOR MORE INFO

MODEL| INPUT (MBH) MIN-MAX| HEATING CAPACITY (MBH)| NET AHRI WATER RATING (MBH)| AFUE (%)| W (IN)| D (IN)| H (IN)| VENT DIAMETER (IN)| APPROX. SHIPPING WEIGHT (LBS)
---|---|---|---|---|---|---|---|---|---
RPTR085HB| 8.5 – 85| 79| 69| 96.0| 19-13/16| 20| 33-5/16| 2 or 3| 140
RPTR110HB| 11 – 110| 103| 90| 96.0| 19-13/16| 20| 33-5/16| 2 or 3| 145
RPTR155HB| 15.5 – 155| 145| 126| 95.0| 19-13/16| 20| 33-5/16| 3| 160
RPTR205HB| 20.5 – 205| 189| 164| 95.0| 19-13/16| 21| 33-5/16| 3| 175
RPTR270HB| 27 – 270| 252| 219| 95.0| 19-13/16| 21| 33-5/16| 3| 185

ARUBA
(AWR SERIES)
Cast Iron – Gas-Fired – Hot Water
Atmospheric VentVELOCITY AWR Gas Fired Stainless Steel Combi Boiler -
Figure 3

  • 84.0% AFUE
  • Eight sizes: 38-280 MBH
  • Natural gas & LP models available
  • Boiler easily field convertible to left side piping
  • Controls located inside the jacket and easily accessible from the front of boiler
  • LWCO Standard

**SPACE HEATING RATINGS

CLICK HERE FOR MORE INFO**

MODEL| NATURAL GAS & LP GAS| AFUE (%)| NO. OF SECS.| W (IN)| D (IN)| H (IN)| VENT DIAM. (IN)| APPROX. SHIPPING WEIGHT (LBS)
---|---|---|---|---|---|---|---|---
INPUT (MBH)| HEATING CAPACITY (MBH)| NET AHRI WATER RATING (MBH)
AWR038B| 38| 32| 28| 84.0| 2| 9-3/4| 31-1/2| 39-1/2| 4| 234
AWR070B| 70| 59| 51| 84.0| 3| 12-7/8| 31-1/2| 39-1/2| 4| 284
AWR105B| 105| 88| 77| 84.0| 4| 15-3/8| 31-1/2| 39-1/2| 5| 334
AWR140B| 140| 117| 102| 84.0| 5| 18-1/2| 31-1/2| 39-1/2| 6| 384
AWR175B| 175| 146| 127| 84.0| 6| 21-1/2| 31-3/4| 39-1/2| 7| 434
AWR210B| 210| 176| 153| 84.0| 7| 24-5/8| 33-1/2| 39-1/2| 7| 484
AWR245B| 245| 205| 178| 84.0| 8| 27-5/8| 33-1/2| 39-1/2| 8| 533
AWR280B| 280| 234| 203| 84.0| 9| 30-3/4| 33-1/2| 39-1/2| 8| 583

BALI 2
(BWF SERIES)
Cast Iron – Gas-Fired
Hot Water – Power VentVELOCITY AWR Gas Fired Stainless Steel Combi
Boiler - Figure 4

  • Cast iron heat exchanger and stainless steel burners
  • Integral fan for sidewall venting
  • Six sizes available in natural or LP gas
  • Limited lifetime warranty
  • LWCO standard equipment
  • Optional direct vent kit available
  • Boiler easily field convertible to left side piping

CLICK HERE FOR MORE INFO

BWF Space Heating Ratings| # of Sections| ‘A’ Width| Connection Size| Water Content| Approx. Shipping Weight| Optional Direct Vent Kit
---|---|---|---|---|---|---
Basic Boiler Model| Fuel| Input| Heating Capacity| Net AHRI Rating, Water| AFUE| Gas| Vent
MBH| MBH| MBH| %| (inch)| (NPT)| (inch)| (gal)| (lbs)| (PN)
BWF070BN| NAT. GAS| 70| 60| 52| 85.0| 3| 12-3/4| 1/2| 3| 2| 260| 110019-03
BWF105BN| NAT. GAS| 105| 90| 78| 85.0| 4| 15-1/2| 1/2| 3| 3| 310| 110019-04
BWF140BN| NAT. GAS| 140| 120| 104| 85.0| 5| 18-1/2| 1/2| 3| 4| 360| 110019-05
BWF175BN| NAT. GAS| 175| 150| 130| 85.0| 6| 21-1/2| 1/2| 3| 5| 415| 110019-06
BWF210BN| NAT. GAS| 210| 179| 156| 85.0| 7| 24-3/4| 3/4| 3| 6| 470| 110019-07
BWF245BN| NAT. GAS| 245| 208| 181| 84.0| 8| 27-3/4| 3/4| 4| 7| 525| 110019-08
BWF063BL| PROPANE| 63| 54| 47| 85.0| 3| 12-3/4| 1/2| 3| 2| 260| 110019-03
BWF094BL| PROPANE| 94.5| 81| 70| 85.0| 4| 15-1/2| 1/2| 3| 3| 310| 110019-04
BWF126BL| PROPANE| 126| 108| 94| 85.0| 5| 18-1/2| 1/2| 3| 4| 360| 110019-05
BWF157BL| PROPANE| 157.5| 135| 117| 85.0| 6| 21-1/2| 1/2| 3| 5| 415| 110019-06
BWF189BL| PROPANE| 189| 161| 140| 85.0| 7| 24-3/4| 3/4| 3| 6| 470| 110019-07
BWF220BL| PROPANE| 220.5| 187| 163| 84.0| 8| 27-3/4| 3/4| 4| 7| 525| 110019-08

Direct Vent Kit is included with high altitude models.

BERMUDA
(BSI SERIES)
Cast Iron – Gas-Fired
Atmospheric Vent

  • Up to 82.2% AFUE
  • Seven sizes 69-276 MBH
  • Natural gas & LP models available
  • Fully assembled or available as knock-down package
  • Near boiler piping kit available separately for ease of installation

CLICK HERE FOR MORE INFO

BSI SPACE HEATING RATINGS NATURAL AND LP GAS| NO. OF SEC.| DIMENSIONS (IN.)| SHIPPING WEIGHT (LBS)
---|---|---|---
CROWN MODEL NUMBER| INPUT (MBH)| HEATING CAPACITY (MBH)| AHRI NET RATING STEAM (MBH)| AFUE (%)| “A” (in)| “B” (in)| “C” (in)| “D” (in)
SQ. FT.| MBH
BSI069| 69| 57| 179| 43| 82.0| 3| 12-3/4| 28| 40-7/16| 4| 365
BSI103| 103| 85| 267| 64| 82.0| 4| 16| 28| 40-7/16| 5| 432
BSI138| 138| 113| 354| 85| 82.0| 5| 19-1/4| 28| 40-7/16| 6| 504
BSI172| 172| 142| 446| 107| 82.1| 6| 22-1/2| 28| 40-7/16| 6| 589
BSI207| 207| 171| 533| 128| 82.1| 7| 25-3/4| 30| 40-7/16| 7| 669
BSI241 †| 241| 199| 621| 149| 82.2| 8| 29| 30| 40-7/16| 7| 745
BSI276 †| 276| 229| 717| 172| 82.2| 9| 32-1/4| 30| 40-7/16| 8| 826

  1. Not for use at altitudes above 2,000 ft. in natural or LP gas.
    †Available as semi-packaged boiler.

CLICK HERE FOR MORE INFO

TOBAGO
(TWB SERIES)
Cast Iron – Oil-Fired – Water
Atmospheric Vent

  • ENERGY STAR® rated with efficiencies up to 87.3%
  • Three physical sizes with firing rates from 0.65-1.90 GPH
  • Beckett AFG burner standard; Carlin & Riello burners optional on most sizes
  • Burner packaged separately for easier handling
  • Optional front-mounted tankless coil for domestic hot water supply
  • Hydrolevel Hydrostat with low water cut off

TWB SPACE HEATING RATINGS| NO. OF SECS.| TANKLESS HEATER| DIMENSIONS| SHIPPING WEIGHT
---|---|---|---|---
CROWN MODEL NUMBER| BURNER INPUT| HEATING CAPACITY| AHRI NET RATING WATER| AFUE (%)| “A”| “B”| “C”
(GAL/HR)| (MBH)| (MBH)| (GPM)| (in.)| (in.)| (in.)| (LBS)
TWB065| 0.65| 80| 70| 87.3| 3| 2.75| 17-3/8| 8-15/16| 6| 560
TWB075| 0.75| 92| 80| 87.0
| 3| 3.00| 17-3/8| 8-15/16| 6| 560
TWB100| 1.00| 122| 106| 86.3| 3| 3.25| 17-3/8| 8-15/16| 6| 560
TWB125| 1.20| 148| 129| 87.0*| 4| 3.75| 22-3/8| 10-13/16| 7| 680
TWB150| 1.50| 182| 158| 86.0| 4| 4.00| 22-3/8| 10-13/16| 7| 680
TWB175| 1.75| 214| 186| 86.4| 5| 4.25| 27-3/8| 13-5/16| 8| 800
TWB200| 1.90| 231| 201| 86.1| 5| 4.75| 27-3/8| 13-5/16| 8| 800

  • ENERGY STAR® certified product
    Notes:

    1. Net Ratings are based on piping and pick-up allowances of 1.15. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.
    2. Burner Capacity Rating, GPH is based on #2 oil with a Gross Heating Value equal to 140000 BTU/Gal.
    3. Tankless heater ratings based on 40F inlet water, 140F outlet water, and 190F boiler water. Ratings are also based on 5 minute intermittent draws with 10 minutes between draws.

FREEPORT II
(FWZ SERIES)
Cast Iron – Oil-Fired – Hot Water
Atmospheric Vent

  • Six sizes: 0.60-1.60 GPH
  • Swing door with burner disconnect plug for easy access to all heating surfaces through the front
  • Beckett AFG burner standard; Carlin & Riello burners optional on most sizes

SPACE HEATING RATINGS
CLICK HERE FOR MORE INFO

MODEL| BURNER INPUT 1 (GPH)| HEATING CAPACITY (MBH)| NET AHRI WATER RATING (MBH)| AFUE (%)| NO. OF SECS.| W (IN)| D (IN)| H (IN)| VENT DIAM. (IN)| APPROX. SHIPPING WEIGHT (LBS)
---|---|---|---|---|---|---|---|---|---|---
FWZ060| 0.60| 73| 63| 86.0| 2| 20-3/4| 16-1/4| 31-1/2| 5| 430
FWZ080| 0.80| 97| 84| 86.3| 2| 20-3/4| 16-1/4| 31-1/2| 5| 430
FWZ081| 0.80| 99| 86| 87.0| 3| 20-3/4| 22-1/4| 31-1/2| 6| 545
FWZ100| 1.00| 123| 107| 87.0
| 3| 20-3/4| 22-1/4| 31-1/2| 6| 545
FWZ130| 1.30| 160| 139| 87.0| 4| 20-3/4| 28-1/4| 31-1/2| 6| 658
FWZ160| 1.60| 197| 171| 87.0
| 5| 20-3/4| 34-1/4| 31-1/2| 7| 771

  1. Input based on 140 MBH per gallon #2 fuel oil
  • ENERGY STAR® certified product

FREEPORT II
(FSZ SERIES)
Cast Iron – Oil-Fired – Steam
Atmospheric Vent

  • Up to 86.0% AFUE
  • Four sizes: 0.80-1.60 GPH
  • Optional side-mounted tankless coil for domestic hot water
  • Near boiler piping kit available separately for ease of installation

SPACE HEATING RATINGS
CLICK HERE FOR MORE INFO

MODEL| BURNER INPUT 2 (GPH)| HEATING CAPACITY (MBH)| NET AHRI STEAM RATING| AFUE (%)| NO. OF SECS.| W (IN)| D (IN)| H (IN)| VENT DIAMETER (IN)| TANKLESS HEATER (GPM) 1| APPROX. SHIPPING WEIGHT (LBS)
---|---|---|---|---|---|---|---|---|---|---|---
(MBH)| (SQ. FT.)
FSZ080| 0.80| 97| 73| 303| 85.7| 3| 22-1/2| 22-1/4| 38-1/2| 6| 3.00| 607
FSZ100| 1.00| 122| 92| 381| 86.0| 3| 22-1/2| 22-1/4| 38-1/2| 6| 3.25| 607
FSZ130| 1.30| 158| 119| 494| 86.0| 4| 22-1/2| 28-1/4| 38-1/2| 6| 3.50| 744
FSZ160| 1.60| 195| 146| 610| 85.9| 5| 22-1/2| 34-1/4| 38-1/2| 7| 4.00| 881

  1. Tankless heater ratings based on an average temperature rise of 90°F with 200°F boiler water temperature and 40°F heater inlet temperature (intermittent draw).
  2. Input based on 140 MBH per gallon #2 fuel oil.

KINGSTON
(KSB SERIES)
Cast Iron – Oil-Fired – Steam
Atmospheric Vent

  • Efficiencies up to 86.4% AFUE
  • Three physical sizes with firing rates from 0.65-1.90 GPH
  • Optional side-mounted tankless coil for domestic hot water
  • Beckett AFG burner standard; Carlin & Riello burners optional on most sizes
  • Burner packaged separately for easier handling
  • Near boiler piping kit available separately for ease of installation

CLICK HERE FOR MORE INFO

KSB SPACE HEATING RATINGS| NO. OF SECS.| TANKLESS HEATER| DIMENSIONS| SHIPPING WEIGHT
---|---|---|---|---
CROWN MODEL NUMBER| BURNER INPUT| HEATING CAPACITY| AHRI NET RATING STEAM| AFUE (%)| “A”| “B”| “C”
(GAL/HR)| (MBH)| (Sq. Ft.)| (MBH)| (GPM)| (in.)| (in.)| (in.)| (LBS)
KSB065| 0.65| 79| 246| 59| 85.1| 3| 2.25| 17-3/8| 8-15/16| 6| 570
KSB075| 0.75| 91| 283| 68| 85.7| 3| 2.25| 17-3/8| 8-15/16| 6| 570
KSB100| 1.00| 121| 379| 91| 85.0| 3| 2.50| 17-3/8| 8-15/16| 6| 570
KSB125| 1.20| 147| 458| 110| 86.4| 4| 2.75| 22-3/8| 10-13/16| 7| 690
KSB150| 1.50| 181| 567| 136| 85.1| 4| 3.00| 22-3/8| 10-13/16| 7| 690
KSB175| 1.75| 212| 663| 159| 85.6| 5| 3.25| 27-3/8| 13-5/16| 8| 810
KSB200| 1.90| 230| 721| 173| 85.3| 5| 3.50| 27-3/8| 13-5/16| 8| 810

Notes:

  1. Net Ratings are based on piping and pick-up allowances of 1.333. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.
  2. Burner Capacity Rating, GPH is based on #2 oil with a Gross Heating Value equal to 140000 BTU/Gal.
  3. Tankless heater ratings based on 40F inlet water, 140F outlet water, and 190F boiler water. Ratings are also based on 5 minute intermittent draws with 10 minutes between draws.

Condensing – Direct Vent – Stainless Steel
Gas-Fired – Hot Water – Water Tube

  • Five Sizes: 399-800 MBH
  • 5:1 turndown ratio
  • Up to 97% thermal efficiency
  • Stackable for floor space savings
  • Natural gas and LP applications – consult manual

SPACE HEATING RATINGS
CLICK HERE FOR MORE INFO

MODEL| MAX. INPUT (MBH)| MIN. INPUT (MBH)| HEATING CAPACITY (MBH)| NET AHRI WATER RATING (MBH)| THERMAL EFFICIENCY| W (IN)| D (IN)| H (IN)| VENT DIAMETER (IN)| APPROX. SHIPPING WEIGHT (LBS)
---|---|---|---|---|---|---|---|---|---|---
PHNTM399C| 399| 80| 375| 326| 94.1†| 16-7/8| 31-3/16| 43-1/2| 4| 316
PHNTM500C| 500| 100| 485
| 422| 97.0†| 16-7/8| 46-1/2| 35-1/16| 4| 368
PHNTM600C| 625| 125| 594| 517| 95.0†| 16-7/8| 49-1/2| 35-1/16| 6| 458
PHNTM700C| 725| 145| 689
| 599| 95.0†| 16-7/8| 49-1/2| 35-1/16| 6| 458
PHNTM800C| 800| 160| 760*| 661| 95.0†| 16-7/8| 53-5/16| 35-1/16| 6| 500

*Gross output
†Thermal efficiency
ENERGY STAR® certified product Condensing – Direct Vent – Stainless Steel
Gas-Fired – Hot Water – Fire Tube**

  • 95% thermal efficiency
  • 10:1 turndown ratio
  • Two sizes: 320 & 399 MBH
  • Field convertible to LP gas with optional kit
  • Can be floor or wall mounted

SPACE HEATING RATINGS
CLICK HERE FOR MORE INFO

MODEL| INPUT
MIN-MAX
(MBH)| HEATING
CAPACITY
(MBH)| AHRI NET
RATING
(MBH)| THERMAL
EFFICIENCY%| W
(IN)| D
(IN)| H
(IN)| VENT
DIAMETER
(IN)| APPROX.
SHIPPING
WEIGHT (LBS)
---|---|---|---|---|---|---|---|---|---
RPTR320HB| 32-320| 304| 264| 95.0| 23| 22.4| 45.28| 4| 270
RPTR399HB| 39.9-399| 379| 330| 95.0| 23| 22.4| 45.28| 4| 275

SERIES 24
Gas-Fired Steam

  • Nine sizes: 476-1863 MBH gross output
  • Cast iron sectional heat exchanger and push nipples
  • Easily assembled with short individual draw rods
  • Optional tankless heater for domestic hot water
  • Top or rear vent connections

SERIES 24 STEAM (GAS-FIRED)
SPACE HEATING RATINGS

CLICK HERE FOR MORE INFO

CROWN BOILER MODEL| HORSE- POWER| GROSS OUTPUT (MBH)| AHRI NET RATING| BURNER INPUT| THERMAL EFFICIENCY % STEAM| WATER CONTENT (GAL.)| BOILER WEIGHT w/WATER
(LBS.)| NO. OF SEC.| VENT COLLAR DIA. (IN.)| APPROX. SHIPPING WEIGHT (LBS)
---|---|---|---|---|---|---|---|---|---|---
SQ. FT. STEAM| MBH STEAM| GAS (MBH)| GAS| STEAM| STEAM
24-04| 14.1| 476| 1488| 357| 594| 80.1| 53.0| 1811| 4| 7| 1590
24-05| 18.9| 634| 1983| 476| 792| 80.1| 61.5| 2184| 5| 8| 1902
24-06| 23.8| 793| 2479| 595| 990| 80.1| 70.0| 2557| 6| 8| 2218
24-07| 28.0| 940| 2938| 705| 1174| 80.1| 78.5| 2930| 7| 8| 2534
24-08| 32.5| 1089| 3404| 817| 1358| 80.2| 87.0| 3303| 8| 10| 2846
24-09| 39.3| 1316| 4133| 992| 1641| 80.2| 95.5| 3676| 9| 10| 3227
24-10| 45.0| 1497| 4758| 1142| 1867| 80.2| 104.0| 4048| 10| 10| 3559
24-11| 50.5| 1681| 5396| 1295| 2093| 80.3| 112.5| 4421| 11| 12| 3870
24-12| 55.3| 1863| 5850| 1404| 2320| 80.3| 121.0| 4794| 12| 12| 4197

Notes:

  1. Trim suffix S = Steam Boiler
    Fuel suffix N = Natural Gas

  2. I=B=R net ratings shown are based on piping and pick-up allowances which vary from 1.333 to 1.289 for steam. Consult manufacturer for installations having unusual piping and pick-up requirements, such as intermittent system operation, extensive piping systems, etc.

  3. Firebox volume does not include added volume of 8” extended burner mounting plate (BMP). If 8” BMP is specified (refer to Figure 1), add 0.7 cu. ft. to volume listed above.

  4. Boiler ratings are based on 9.7% CO2 (natural gas), + .10” (inches) water column pressure at boiler flue outlet. Ratings shown above apply at altitudes up to 2,000 feet on gas. For altitudes above those indicated, the ratings should be reduced at the rate of 4% for each 1000 feet above sea level.

Maximum Allowable Working Pressure: Steam Boiler – 15 PSI,
Standard Safety (Relief) Valve Set Pressure: Steam Boiler – 15 PSI SERIES 49
Cast Iron – Gas-Fired – Steam
Atmospheric Vent

  • Tappings on both end sections, return can be piped left or right
  • Cast iron sectional heat exchanger
  • Natural Gas Only
  • Sectional knock-down (299 to 550 MBH)
  • 2” Skim taping

SERIES 49 STEAM (NG-FIRED ONLY)
Space Heating Ratings
CLICK HERE FOR MORE INFO

Boiler Model| Input| Heating Capacity| Net AHRI Rating| AFUE 2 (%)| No. Of Sections| W (In.)| H (In.)| D (In.)| Nominal Vent Dia. 3 (In.)| Supply (NPT)| Return (NPT)| Gas Conn 4 **(NPT)| Approx. Shipping Weight (Lbs)
---|---|---|---|---|---|---|---|---|---|---|---|---|---
Steam
(MBH)| (MBH)| MBH| Sq. Ft.**
49-299S| 299| 246| 185| 771| 82.0| 7| 36-9/16| 40-3/4| 40| 8| (2) 2| 2| 3/4| 8815
49-350S| 350| 2841| 213| 890| 81.02| 8| 41-5/8| 40-3/4| 40| 6 & 7| (3) 2| 2| 1/2 & 3/4| 10085
49-399S| 399| 3231| 242| 1,012| 81.02| 9| 46-11/16| 40-3/4| 40| 6 & 8| (3) 2| 2| 1/2 & 3/4| 11235
49-450S| 450| 3651| 274| 1,143| 81.02| 10| 51-3/4| 40-3/4| 40| 7 & 8| (4) 2| 2| 3/4 & 3/4| 12395
49-500S| 500| 4051| 304| 1,269| 81.02| 11| 56-13/16| 40-3/4| 40| 7 & 8| (4) 2| 2| 3/4 & 3/4| 13545
49-550S| 550| 4461| 335| 1,397| 81.02| 12| 61-7/8| 40-3/4| 40| 8 & 8| (4) 2| 2| 3/4 & 3/4| 14695

  1. Gross output on models with inputs over 300MBH
  2. Thermal efficiency on models with inputs over 300MBH
  3. e.g. 6 & 7 indicates both 6 and 7 inch collar diameters (see installation manual)
  4. e.g. 1/2 & 3/4 indicates both 1/2 and 3/4 inch gas connections
  5. Weight for knock-down units

INDIRECT WATER HEATERS

VELOCITY AWR Gas Fired Stainless Steel Combi Boiler - logo
6 (MS2)
Stainless Steel – Indirect Water Heater

  • Five sizes: 30-119 gallon
  • Rugged design with coated steel jacket and heavy duty polymer top and bottom to resist cracks and abrasions (Available on sizes 30-75 only)
  • Large diameter and smooth surface stainless steel coil maintains superior performance over the life of the tank
  • Adjustable feet for uneven floors (Available on sizes 30-75 ONLY)

AHRI Performance Ratings

CLICK HERE FOR MORE INFO

Model| First Hour Rating| Continuous Draw Rating| Standby Loss (°F/hr)| Minimum Boiler Output (MBH)| Boiler Water Through Coil| POTABLE VOLUME (GAL)| D (IN)| H (IN)| APPROX SHIPPING WEIGHT (LBS)
---|---|---|---|---|---|---|---|---|---
(Gal/hr)| (Gal/hr)| Min Flow (Gal/min)| Head Loss (ft w.c.)
MS2-030| 162| 138| 1.4| 87| 8.0| 2.6| 30.1| 23-1/2| 33-1/8| 69
MS2-040| 192| 162| 1.1| 101| 8.0| 2.8| 37.9| 23-1/2| 39-3/8| 82
MS2-050| 236| 193| 0.9| 121| 8.0| 2.9| 50.6| 23-1/2| 49-3/4| 112
MS2-075| 307| 238| 1.0| 150| 8.0| 4.5| 74.0| 23-1/2| 68-3/4| 146
MS2-119| 497| 417| 1.4| 264| 14.0| 4.2| 111.3| 30-3/4| 62-7/8| 251

VELOCITY AWR Gas Fired Stainless Steel Combi Boiler - Figure
15

MEGA-STOR BUFFER TANK

  • Available in 3 sizes (30, 50, 75)
  • Rugged design with coated steel jacket and heavy-duty polymer top and bottom
  • Tank cylinder made of 444 stainless steel
  • Adjustable feet for uneven floors
  • 1-1/2” system connections

CLICK HERE FOR MORE INFO

Model VOLUME (GAL.) DIMENSIONS IN INCHES WEIGHT
HEIGHT WIDTH NET FULL
MSB-030 31.4 33-1/8 23-1/2
MSB-050 52.6 49-3/4 23-1/2
MSB-075 76.3 68-3/4 23-1/2

VELOCITY AWR Gas Fired Stainless Steel Combi Boiler - Figure
16 MAXI-THERM II (MT)
Glass Lined – Indirect Water Heater

  • Three sizes: 40, 50 and 120 gallons
  • Porcelain enamel tank
  • Porcelain enamel coated smooth coil surface

CLICK HERE FOR MORE INFO
AHRI Performance Ratings

Model| First Hour Rating| Continuous Draw Rating| Standby Loss (°F/hr)| Minimum Boiler Output (MBH)| Boiler Water Through Coil| POTABLE VOLUME (GAL)| D (IN)| H (IN)| APPROX SHIPPING WEIGHT (LBS)
---|---|---|---|---|---|---|---|---|---
(Gal/hr)| (Gal/hr)| Min Flow (Gal/min)| Head Loss
(ft w.c.)
MT040 GBR| 205| 180| 1.1| 120| 13.7| 1.5| 37| 22| 41-1/8| 172
MT050 GBR| 210| 180| 0.9| 120| 13.7| 1.5| 43| 22| 46-1/4| 180
MT120 GBC| 400| 325| 0.4| 220| 14.0| 5.0| 107| 28-1/4| 62-1/2| 415

Note: First hour ratings are based on the following conditions: 180 deg. F Boiler Supply, 58 deg. F cold water in, 135 deg. F domestic water out.

FURNACES

OIL FURNACE SERIESVELOCITY AWR Gas Fired Stainless Steel Combi Boiler -
Figure 17

  • Five styles available: Low Profile High Boy,
  • Low Boy, Rear Flue, Low Boy Front Flue,
  • Horizontal/Counterflow, Hi Boy
  • Limited lifetime warranty on heat exchanger
  • 5-year parts warranty

CLICK HERE FOR MORE INFO

STYLE| MODEL| BTU/H OUTPUT (1000’S)| AFUE%| Energy Star| MAX RECOMMENDED
A/C| W (IN)| D (IN)| H (IN)| APPROX. SHIPPING WEIGHT (LBS)
---|---|---|---|---|---|---|---|---|---
LOW PROFILE HIGH BOY| VCSHB60-90ABP| 60 / 72 / 90| 85%| NO| 4 TON| 21| 30| 45| 270
LOW PROFILE HIGH BOY| VCSHB60-90ABT| 60 / 72 / 90| 85%*| YES| 4 TON| 21| 30| 45| 270
LOW BOY – FRONT| VCLBF68-112DBP| 70 / 88 / 98 / 114| 85%| NO| 3 1/2 TON| 22-1/4| 47| 41-1/2| 300
LOW BOY – REAR| VCLBR68-112DBP| 70 / 88 / 98 / 114| 85%| NO| 3 1/2 TON| 22-1/4| 47| 41-1/2| 300
HORIZONTAL / COUNTER FLOW| VCHC68-96CBP| 70 / 88 / 98 / 114| 85%| NO| 3 1/2 TON| 22-1/4| 22-1/4| 61-1/4| 280
HI BOY| VCH8FA119P60B| 101 / 119 / 132| 85%| NO| 5 TON| 24-1/2| 36-1/2| 50-1/8| 316

  • ENERGY STAR® certified product

ADAVANCED FEATURES

INTEGRATED BOILER CONTROL
Features temperature control, relay and ignition functions in a single module. Included LWCO and additional circulator output for a second heating zone or an indirect water heater like the Mega-Stor II.
Standard on AWR & BWF HYDROLEVEL 3250
The Hydrolevel HydroStat 3250 control provides temperature limit and low water cutoff, while allowing for outdoor reset control with the addition of an Outdoor Sensor Kit.
Standard on TWB & FWZ
CLICK HERE FOR MORE INFO

PAT Connect is a commissioning, diagnostic and service tool consisting of a Bluetooth Adaptor and mobile device app.
CLICK HERE FOR MORE INFO

PHANTOM ADAPTIVE COMBUSTION
Adaptive combustion technology features

  • Field convertible to LP- No conversion Kit required
  • Simple start-up
  • Rate based temperature reset- no outdoor sensor required

Standard on Phantom II Combi and Heat Only boilers
CLICK HERE FOR MORE INFO

ACCESSORIES

STEAM NEAR BOILER PIPING KITS The near boiler piping kit will assist in delivering “dry” steam to the heating system, reduce short cycling, eliminate water hammering and protect against system flooding. Kit includes all components required to complete the near boiler piping as recommended in the installation manual.
Available on BSI, FSZ, KSB & S49
CLICK HERE FOR MORE INFO

CONDENSING ACCESSORIES CPVC/PVC Vent Kits
Leg Kit Raptor
Floor Stand Phantom II
Phantom II Heat Only Primary/ Secondary Header

Warranty Information Guide (Parts/Heat Exchanger)

RESIDENTIAL

WATER STEAM
OIL GAS
TOBAGO TWB FREEPORT FWZ

BERMUDA
| | | | ***
Input (GPH): .65, .75, 1.00, 1.25, 1.50, 1.75, 2.00| Input (GPH): .60, .80, 81, 1.00, 1.30, 1.60| Input (GPH): .80, 1.00, 1.30, 1.60| Input (GPH): .65, .75, 1.00, 1.25, 1.50, 1.75, 2.00| Input (MBH): 69, 103, 138, 172, 207, 241, 276
Warranty (Heat Exchanger)| 20 years
| Warranty (Heat Exchanger)| 20 years| Warranty (Heat Exchanger)| 12 years| Warranty (Heat Exchanger)| 12 years| Warranty (Heat Exchanger)| 12 years
Warranty (Parts)| 1 year| Warranty (Parts)| 1 year| Warranty (Parts)| 1 year| Warranty (Parts)| 1 year| Warranty (Parts)| 1 year

RESIDENTIAL
WATER
GAS
NON-CONDENSING

ARUBA 5 BALI 2
Input (MBH): 38, 70, 105, 140, 175, 210, 245, 280 Nat. Gas Input (MBH):

70-245 Propane Input (MBH): 63-220
Warranty (Heat Exchanger)| 20 years| Warranty (Heat Exchanger)| 20 years
Warranty (Parts)| 1 year| Warranty (Parts)| 1 year

RESIDENTIAL
WATER
GAS
CONDENSING

PHANTOM II COMBI PHANTOM II HEAT ONLY PHANTOM-X RAPTOR
Input (MBH): 136, 200 10:1 Turndown Input (MBH): 120, 150, 180 10:1 Turndown
Input (MBH): 210, 285 5:1 Turndown Input (MBH): 85, 110, 155, 205, 270 10:1

Turndown.
Warranty (Heat Exchanger)| 7 years| Warranty (Heat Exchanger)| 7 years| Warranty (Heat Exchanger)| 7 years| Warranty (Heat Exchanger)| 7 years
Warranty (Parts)| 5 years| Warranty (Parts)| 5 years| Warranty (Parts)| 5 years| Warranty (Parts)| 5 years

RESIDENTIAL/COMMERCIAL
INDIRECT WATER HEATERS

MEGA-STOR II BUFFER TANK
**** ****
Size: 30, 40, 50, 75, 119 Size: 30, 50, 75
Warranty (Heat Exchanger and Tank) 8 years**
Warranty (Parts) 1 year

COMMERCIAL

WATER STEAM WATER/ STEAM WATER
NON-CONDENSING GAS

CONDENSING
FW| SERIES 49| SERIES 24| RAPTOR-X| PHANTOM-X
| | | |
Nat. Gas Input (MBH): 433-1,299
Oil Input (GPH): 3.0 – 9.0| Nat. Gas Input (MBH): 299, 350, 399, 450, 500, 550| Nat. Gas Input (MBH): 440 – 2320
Oil Input (GPH): 3.05 – 16.0| Input (MBH): 320, 399
10:1 Turndown| Input (MBH): 399, 500, 625, 725, 800 5:1 Turndown
Warranty (Heat Exchanger)| 10 years| Warranty (Heat Exchanger)| 10 years| Warranty (Heat Exchanger)| 10 years| Warranty (Heat Exchanger)| 5 years| Warranty (Heat Exchanger)| 5 years*
Warranty (Parts)| 1 year| Warranty (Parts)| 1 year| Warranty (Parts)| 1 year| Warranty (Parts)| 1 year| Warranty (Parts)| 1 year

VELOCITY logoVelocityBoilerWorks.com

*Boiler Heat Exchanger warranty covers manufacturing defects to the original owner only. A proof of original purchase will be required. For full and pro-rated terms, please go to; https://www.velocityboilerworks.com/support/product-warranties/
Limited Lifetime Warranty for Residential Installations for the Heat Exchanger and Tank cover manufacturing defects to the original owner only. A proof of original purchase will be required.
For complete details please go to; https://www.velocityboilerworks.com/support/product-warranties/
[
CLICK HERE FOR MORE INFO**](https://www.velocityboilerworks.com/documents /Velocity-Warranty-Information-Guide.pdf)

  • High-grade materials and “smart” controls for maximum efficiency and cost savings
  • Safe, reliable and durable products for years of exceptional performance
  • Expertly engineered, inspected and certified to meet the most rigorous standards for quality, safety and efficiency
  • Delivered fully assembled and tested, easy to install and service
  • A wide range of venting options and boiler sizes to fit the needs of any home or business
  • Backed by superior warranties, with friendly and experienced technicians ready to answer questions and provide support

At Velocity Boiler Works our products are built to the highest standards, earning one or more of the following marks:

VELOCITY AWR Gas Fired Stainless Steel Combi Boiler - Symbol
5 Quality Value & Service
VelocityBoilerWorks.com
Philadelphia, PA
PSG-04/23
PN980535

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Velocity User Manuals

Related Manuals