GE Lighting CFIXRSCR6CRVD Recessed Downlight Installation Guide
- June 10, 2024
- GE Lighting
Table of Contents
GE Lighting CFIXRSCR6CRVD Recessed Downlight
Getting Started
For set-up help, visit cyncsupportgelighting.com or call 1-844-302-2943
Let’s Do It
Included:
You’ll need:
GE is a trademark of General Electric Company. Used under trademark license. Amazon, Alexa, and all related logos are trademarks of Amazon.com, Inc, or its affiliates Google and other related marks and logos ere trademarks of Goodie LIC.
Specifications
Dimming Capability
NOT FOR USE WITH DIMMER SWITCHES. Compatible with only CYNC smart dimmers that provide dimming at the switch or through the CYNC App.
STOP
Before you begin: Read these instructions completely and carefully.
WARNING : RISK OF ELECTRIC SHOCK
Risk of fire or electric shock. Instol this kit only in luminaires that have
the construction features and dimensions shown in the photographs and/or
drawings and where the input rating of the retrofit kit does not exceed the
input rating of the luminaire. Do not make or alter any open holes in an
enclosure of wiring or electrical components during kit installation
Prepare Electrical Wiring
ELECTRICAL REQUIREMENTS
The LED downlights must be supplied with 120VAC 60Hz
GROUNDING INSTRUCTIONS
The grounding and bonding of the overall system shall be done in accordance
with National Electric Code(NEC) Article 600 and local codes.
You Got This!
And we’re here to help.
For in-depth instructional videos and a guided tour through the installation,
go to: cyncsupport.gelighting.com or call
1-844-302-2943
INSTALLATION
Step 1
Turn Off The Power!
Turn off power af the source to the recessed housing(s) that you are
installing the fixture(s) in,
Step 2
Remove Existing Trim and Bulb
Remove the existing trim and bulb, revealing the housing and the existing
socket inside.
Step 3
Determine the Mounting Method
The Recessed Downlight is designed to install in most 6 in, and 5 in recessed
can fixtures. Use either the torsion spring or flip clip.
- Housing with torsion bracket, Use the manufacturer-installed torsion springs for installation.
- Mousing without torsion bracket. Replace the torsion springs with the flip dips included in the packaging using a screwdriver.
Step 4
Installing the Base
Medium Base Sockets Screw the medium (E26) base into the socket and then
connect the base to the fixture using the plug connector.
Plug-In Connection
Insert the plug connector from the ceiling into the plug connector on the
fixture.
Step 5
Finish Installation
- Housing with torsion bracket, Check that the “torsion springs” are firmly attached. Compress the torsion springs and insert into the bracket inside the housing. Release springs and gently push up until flush with the celling.
- Housing without torsion bracket, Check that the flip dips* are firmly attached. Canter the fidure in the housing opening and gently push up until flush with the ceiling.
Congratulations!
You’ve completed the Recessed Downlight installation.
Next
Enable Your Voice Assistant
Connect to your Amazon Alexa or Hey Google voice assistants in the CYNC App.
Then try this
- Alexa, turn off the living room. Hey Googie, turn on the lights.
- Alexa, turn on the bedroom. Hey Google, good morning.
- Alexa set kitchen to 50% Hey Google, I’m leaving.
FCC Compliance Statement Compliance
Warning Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate
the equipment. Note: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to protect reasonably against harmful interference
in a residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. Suppose this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on. In that case, the user is encouraged to try
to correct the interference by one or more of the folowing measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device must not be co-located or operating in conjunction with any other
antenna or transmitter.
This device complies with part 15 of FCC rules. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
RF Exposure Information:
Caution: To maintain compliance with the FCC’s RF exposure guidelines, place
the product at least 20cm from nearby persons.
IC Statement
This device complies with RSS247 of Industry Canada. Cet appareil se conforme à RSS247 de Canada d’Industrie. This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(a) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Like your new Recessed Downlight?
Share your experience!
Leave a review where you purchased the product.
THIS ART IS SUPPLIED AT 100% SCALE DO NOT RESIZE, RESHAPE OR ALTER
Documents / Resources
| GE
Lighting CFIXRSCR6CRVD Recessed
Downlight
[pdf] Installation Guide
CFIXRSCR6CRVD Recessed Downlight, CFIXRSCR6CRVD, Recessed Downlight, Downlight
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>