OLIMPIA SPLENDID LIMPIA 4 Humidifier Instructions
- June 10, 2024
- OLIMPIA SPLENDID
Table of Contents
LIMPIA 4 Humidifier
Instructions
LIMPIA 4
INSTRUCTION FOR USE AND MAINTENANCE
LIMPIA 4 Humidifier
WARNINGS
- This appliance can be used by children aged from 8 years and above and person with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. (be applicable for the European Countries).
- This appliance is not intended for use by persons (including chalder) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. (be applicable for other countries except the European Countries).
- If the power cable is damaged, it must be replaced by the manufacturer or by its technical support service or by similarly qualified personnel, to prevent any risk to the user.
- To prevent any electrocution risk, it is essential to disconnect the plug from the power socket before performing any maintenance operation on the appliance.
WHEN USING ELECTRICAL APPLIANCES, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:
This product should be used only in accordance with the specifications
outlined in this manual. Usage other than what has been specified here may
result in serious injury.
THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES TO PERSONS OR PROPERTY CAUSED
BY FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL.
- Read this manual carefully before performing any operation (installation, maintenance, use) and follow the instructions contained in each chapter.
- CAUTION To reduce the risk of severe burns, keep this product out of the reach of children and pets.
- CAUTION after removing the packaging, check that the appliance is in perfect condition. The packaging materials must not be left within reach of children as they can be dangerous.
- Disassembly, repair or remodeling by an unauthorized person may result in serious harm and will void the manufactures warranty.
- Do not operate the appliance in case of damaged cord or plug, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment or repairing.
- Always place this humidifier on a firm, flat and level surface at least 60cm from the floor. This humidifier may not work properly on an uneven surface.
- Do not clog the air inlet or outlet, do not position the unit on cloth, mats or any other absorbing material or any other absorbing material.
- Do not permit the area around the humidifier to become damp or wet. If dampness occurs, turn the output of the humidifier down. If the humidifier output volume cannot be turned down, use the humidifier intermittently. Do not allow absorbent materials, such as carpeting, curtains, drapes, or tablecloths, to become damp.
- Do not place humidifier near heat sources such as stoves, radiators and heaters
- Do not place humidifier near electrical outlet
- This product releases mist. Do not place this humidifier directly on wood furniture, flooring or any surfaces that could be damaged by water. Manufacturer does not accept any liability for damage in the case of the unit being placed incorrectly.
- Unplug the appliance during filling and cleaning.
- Once the humidifier has been plugged in, do not tilt or move the unit.
- Do not remove the water tank from the unit while it is on.
- Do not handle the plug with wet hands.
- Do not excessively bend, twist, pull or damage the power cord.
- Avoid placing this product where the humidity spout is pointed directly at an object or person.
- Do not inhale the mist/vapor expelled from the product or drink water from the tank.
- Do not fill the water tank with hot or boiling water.
- Do not use this product in direct sunlight or near a heat source such as a stove, heater or radiator.
- If the water tank becomes cracked or damaged, do not use.
- Do not keep this product running for an extended period of time.
- Unplug the cord when unit is not in use for an extended period of time and/or when no one is home.
- Do not keep water in the tank when not in use for an extended period of time.
- Do not clean the unit, water tank or water reservoir with detergents or chemicals of any kind.
- The use of water additives including ethereal/essential oils, fragrances, eucalyptus, water conditioners, etc. will damage the appliance materials and as a consequence the whole unit. Any use of such additives will void the manufactures warranty.
- Do not use this product near any other electronic device.
- Do not cover the spray spout at any time during use. Do not put anything on or in the tank.
- When unplugging from outlet hold humidifier securely.
- Do not place cord over objects.
- Do not get water in or on the power cord or where it connects to the product.
- Do not use near a sink.
- Do not touch the water tank during operation.
- Do not submerse the unit in water or pour water on the unit or in the humidity spout.
- When emptying water from water tank, pour on drain side.
- Do not cover the spout with cloth or hand and do not use without the spout.
- Use clean or distilled water in tank. Hard water areas will require more frequent cleaning.
- If moisture forms on the walls or windows of the room, turn off the humidifier. The room already has plenty of humidity and additional moisture may cause damage.
- NEVER leave water in the reservoir when the appliance is not in use.
- Empty and clean the humidifier before storage.
- Clean the humidifier before next use.
- Be aware that high humidity levels may encourage the growth of biological organisms in the environment.
- Micro-organisms that may be present in the water or in the environment where the appliance is used or stored, can grow in the water reservoir and be blown in the air causing very serious health risks when the water is not renewed and the tank is not cleaned properly every 3 days.
Clean the water tank every three days.
DISPOSAL
This symbol on the product or its packaging indicates that the appliance
cannot be treated as normal domestic trash, but must be handed in at a
collection point for recycling electric and electronic appliances.
Your contribution to the correct disposal of this product protects the
environment and the health of your fellow men. Health and the environment are
endangered by incorrect disposal.
Further information about the recycling of this product can be obtained from
your local town hall, your refuse collection service, or in the store at which
you bought the product.
This regulation is valid only in EU member states.
MAIN FEATURES AND OPERATING
PRE-OPERATING INSTRUCTION
Select a firm, level, flat location at least 15cm from any wall or object for
proper air flow. Place the humidifier on a water-resistant surface, as water
can damage furniture and some flooring. Do not place unit directly on carpet,
towels, blankets or other absorbent surfaces.
We will not accept responsibility for damage caused by water spillage.
2a- FILLING
Make sure unit is unplugged.
- Separate the tank from the base of the unit.
- Flip over water tank and open the tank lid, turning it to the left.
- Pour cool, clean water directly into the tank. Do not pour anything but water into the tank.
- Close the tank lid, turning it to the right. It is important to FIRMLY secure cap after filing the tank with water.
- Replace the water tank to the base.
- Connect the power with electric outlet.
- Attach tank to base of unit.
- Before turning ON the humidifier make sure there is water in the Bowl.
OPERATING INSTRUCTIONS
A) ON/OFF
Turn the knob to switch the unit On or Off and to regulate the level of mist.
(1) Turn the knob to ON and the humidifier starts working.
(2) Turn the knob clockwise to regulate the level of mist from min. to max.
(3) Turn the knob counter clockwise to regulate the level of mist from max. to
min.
(4) Turn the knob to OFF and the humidifier stops.
B) Timer
Press the TIMER button, when the appliance is working, to set the time (hours)
left until the appliance turns off.
C) Night light
PRESS ONCE: multicolor night light comes on.
PRESS AGAIN: night light comes on with just one color.
PRESS A THIRD TIME: night light goes out.
DAILY MAINTENANCE
Before clearing, turn off the power and unplug the appliance from the
electrical outlet.
Lift off the tank of the humidifier from the housing.
Carry the water tank and the housing to a sink, drain all the remaining water.
Drain and rinse water tank and housing to remove any sediment and dirt.
Wipe clean and dry with clean soft cloth or paper towel.
Refill the water tank with cool tap water as instructed in filling water tank
paragraph.
It is necessary to remove daily any residual water, from both the tank and the tank and the bowl, then clean and dry both and finally refill with new and clean tap water.
CLEANING
Always unplug the unit before servicing in any way.
5a- GENERAL CLEANING
-
Inside the bowl. Pour excess water out of the unit. Wash the unit with fresh water, using a soft paintbrush and a soft cloth as necessary.
Do not submerse the base of the unit into water, or allow water to enter inside the dry air exhaust port of the unit. -
Water tank. Empty water tank. Clean the mist tube with fresh water and a light brush (a soft paintbrush is advised).
-
Outer surface of the unit. Wipe the surface of the unit with a soft, damp cloth if needed. If you notice an accumulation of water during usage, reduce humidity and dry outer surface with a cloth.
-
Ultrasonic Transducer. If you use the hard water, distilled or tap water, you should clean the transducer weekly.
-
Air filter. Remove the grid, clean the filter. Reinstall grid and filter.
-
Purifier filter (if provided). Rinse with clean water and let it dry.
5b- DESCALING
- Depending on usage and waterpipe, cleaning to remove scale may be required weekly or every other week to optimize unit performance.
- If you live in a hard water area, we recommend the use of distilled water or soften water for your humidifier. This will help reduce the precipitation of minerals or white dust
- Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.
5c- ULTRASONIC DISK
- Unplug unit.
- Remove the tank and empty all water from unit bowl and tank.
- Locate the ultrasonic disk on the inside center of the base unit
- ONLY use a soft paintbrush to delicately clean the disk and remove accumulations and deposits.
Do nostrum or scrape the ultrasonic disk.
- Clean the disk with a soft paintbrush. No other cleaning tool should be used. ONLY A PAINTBRUSH.
If calcium becomes difficult to remove with a paintbrush:
- Fill the bowl with mixture of 1 tea spoon of white vinegar and 1 tea spoon of water.
- Let solution stand for 5 minutes.
- With the vinegar in the bowl, clean all interior surfaces with a soft cloth or brush to help remove scale.
- Also check mist nozzle and mist tube in water tank. Clean as needed.
- Rinse the Base thoroughly with water to remove scale and vinegar solution.
5d- END OF SEASON STORAGE
-
Follow the Cleaning and Descaling instructions when the humidifier will be stored at the end of the season.
-
Dry the humidifier completely before storing.
DO NOT store with water inside the bowl or Water Tank. -
Pack the unit in its original carton and store in a cool, dry location.
IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR PERSONAL INJURY.
TROUBLESHOOTING GUIDE
PROBLEM | SOLUTION |
---|
Water vapor and humidity are not
produced.| • Power plug: Unplug and then try again.
• Power Failure: When the power is returned, try again.
• Tank Installation: Make sure the tank is correctly attached.
• The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
Air blows but water vapor is not
produced.| • Excessive Water: Remove a certain amount of water from the tank.
• Detergent residue and/or oil ingredients from cosmetics, etc may be in tank;
wash out tank and try again.
• The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
• If you use hard water, replace with softer water.
Humidity level is low.| • The surface of the ultrasonic disk is dirty: Clean
ultrasonic disk.
• The water in the unit is too cold: Replace with cool, but not cold water.
The humidity has a bad smell.| • Poor maintenance or dirty water: Clean the
product thoroughly, and fill it with fresh water.
White dust is forming on nearby
furniture.| • Hard water may deposit a certain of dust. Dust in the air also
settles because of added humidity in the room. Use distilled water if this
becomes a nuisance.
Unit has stopped working.| • No or low water. Unplug unit and refill tank.
Water is accumulating outside of unit or area surrounding unit.| • Saturation
of humidity. Lower mist control setting.
• Unit not level and water is accumulating. Unplug and place on level surface.
Point spray away from objects. Raise unit on a water-resistant level surface
at least 60 cm from the floor.
Water dripping when refilling.| • Water remaining on bottom of tank. Wipe tank
or tilt to drain before transporting.
Increased noise level.| • Unit must be placed on a flat, level, hard surface.
Make sure it is NOT placed on a soft or absorbent surface.
Flashing light symbols.| • Indicates low water. Unplug and refill tank.
OLIMPIA SPLENDID spa
via Industrial 1/3 25060 Celestica (BS)
www.olimpiasplendid.it
info@olimpiasplendid.it
I data tecniciele caratteristiche estetiche
deli promote Pocono sub ire cambiamenti.
Olympia Splendid siriserva di modifiable in
omni memento senza praise.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>