Microwave Movement Sensor
This product is fitted with a microwave movement sensor. Please see below detailed operating instructions.
Technical Specifications
Operating voltage | 220 ~ 240V AC 50/60Hz |
---|---|
Rated load | 400W (Capacitive load) 800W (Resistive load) |
Stand-by power | ≤0.5W |
Sensitivity
| Ceiling mounted height: 3m| 100% / 75% / 50% / 25% / 10%
Ceiling mounted
height: 6m*
| 100% / 75% / 50%
Wall mounted height: 2m| 100% / 75% / 50% / 25% / 10%
Hold-time| 5s / 30s / 90s / 3min / 20min / 30min
Daylight sensor| 2Lux / 10Lux / 25Lux / 50Lux / Disable
Microwave frequency| 5.8 GHz ±75MHz
Transmitting power| 1mW Max.
Detection range| Ceiling mounted height: 3m| 3- 6m (radius )
Wall mounted height: 1.5-2m| 12-15m
Detection angle| 3600 (Ceiling) / 1200 (Wall)
Working temperature| -200C ~ 600C
*50%, 75%, and 100% detection sensitivity is workable when installed at 6m mounting height. Only 10% and 25% sensitivity are not able to detect motion signals.
Settings
Sensitivity
Sensitivity can be adjusted by selecting the combination on the DIP switches for different applications.
Hold-time
Hold-time refers to the time period that the light remains 100% on if no more
movement is detected.
Daylight sensor
Different daylight thresholds can be preset on DIP switches. Light will always
turn on upon movement if the daylight sensor is disabled.
Troubleshooting
Malfunction Cause Remedy | Cause | Remedy |
---|
The light will not come on
| Incorrect light-control setting selected| Adjust daylight threshold setting
Faulty lamp| Replace lamp
No power supply| Check power to sensor
The lamp is always on| Continuous movement in the detection zone| Check
detection area setting
The lamp is on without any identifiable movement
| The sensor is not mounted for reliably detecting movement| Securely mount enclosure
Movement occurred, but not identified by the sensor (Movement behind wall, movement of small object in immediate lamp vicinity etc.)
| 1. Reduce sensitivity.
2. Check the movement behind walls to avoid facilities such as water pipe, fan, which may mis-trigger the sensor.
The lamp will not work despite movement| Rapid movements are being suppressed to minimize malfunctioning or the detection radius is too small.|
Check detection area setting
Care and Safety
- We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
- For your safety, always switch off the power supply before cleaning.
Thank you for purchasing this light fitting. Please read the instructions
carefully before use to ensure safe and satisfactory operation of this
product. Please retain these
instructions for future reference.
Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before commencing any work. This unit
must be fitted by a competent and qualified electrician. Install in accordance
with IEE Wiring regulations and current Building Regulations. To prevent
electrocution switch off at mains supply before installing or maintaining this
fitting. Ensure other persons cannot restore the electrical supply without
your knowledge. If you are in any doubt, please consult a qualified
electrician. This light fitting should be connected to a circuit with a 30mA
RCD fitted. If replacing an existing fitting, make a careful note of the
connections. This system contains non-replaceable parts and cannot be
serviced. If damage occurs the part should be scrapped. Waste electrical
products should not be disposed of with household waste. Please recycle where
facilities exist. Check with your local authority or retailer for recycling
advice.
Technical data
Layout
-
Plan the desired layout of these fittings carefully, ensuring the cables will reach the distance between the junction box and the light fitting.
-
Avoid locating any cables in positions that would cause a hazard. Position cables and junction boxes (not supplied) away from areas where they may be at risk
from being cut, trapped, or damaged. -
The main supply cable must have a minimum cross-section area of 1.0mm2.
-
Cables must be protected using suitable conduit or plastic trunking.
-
The products can be wall or ceiling mounted. If wall mounting ensure that the power supply is at the bottom.
Installation
Existing fittings must be completely removed before the installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires.
-
Plan the desired layout of these fittings carefully, ensuring the cables will reach the distance between the junction box and the light fitting.
-
Avoid locating any cables in positions that would cause a hazard. Position cables and junction boxes (not supplied) away from areas where they may be at risk
from being cut, trapped, or damaged. -
The main supply cable must have a minimum cross-section area of 1.0mm2.
-
Cables must be protected using suitable conduit or plastic trunking.
-
The products can be wall or ceiling mounted. If wall mounting ensure that the power supply is at the bottom.
-
Note that the switch is turned off before installation.
-
Open the shade and set aside.
-
Hold the product in place and mark the position of the holes.
-
Ensure the wall is capable of holding the weight of the product, or if fitting to a ceiling, ensure there is a joist at the point of fixing to support the weight of the product.
Take care to avoid damaging any concealed wiring and pipes. The correct fixings should be used for brick, cavity walls or plasterboard. -
Fix into position.
-
Pierce the hole in the grommet, and pull the cable through.
-
Wire as detailed below
Wiring
- Having correctly identified the wiring from your existing light fitting, pull the mains wire through the hole and connect to the quick-fit connection block in the following way. No tools are necessary
Check that
- You have correctly identified the wires.
- The connections are tight.
- No loose strands have been left out of the connection block.
Commissioning
- Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
- Refit the shade, ensuring that the seals are correctly located.
- Replace the fuse or circuit breaker and switch it on. Your light is now ready for use.
Fitting/replacing bulbs
- This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.
www.saxbylighting.com.
Saxby Lighting. BH17 7BY