saxby 103936 HeroPro CCT Microwave Bulkhead Installation Guide
- June 10, 2024
- saxby
Table of Contents
saxby 103936 HeroPro CCT Microwave Bulkhead Installation Guide
Microwave Movement Sensor
This product is fitted with a microwave movement sensor. Please see below detailed operating instructions
Technical Specifications
Operating voltage | 220 ~ 240V AC 50/60Hz |
---|---|
Rated load | 400W (Capacitive load) 800W (Resistive load) |
Stand-by power | ≤0.5W |
Sensitivity | Ceiling mounted height: 3m |
Ceiling mountedheight: 6m* | 100% / 75% / 50% |
Wall mounted height: 2m | 100% / 75% / 50% / 25% / 10% |
Hold-time | 5s / 30s / 90s / 3min / 20min / 30min |
Daylight sensor | 2Lux / 10Lux / 25Lux / 50Lux / Disable |
Microwave frequency | 5.8 GHz ±75MHz |
Transmitting power | 1mW Max. |
Detection range | Ceiling mounted height: 3m |
Wall mounted height: 1.5-2m | 12-15m |
Detection angle | 3600 (Ceiling) / 1200 (Wall) |
Working temperature | -200C ~ 600C |
*50%, 75%, 100% detection sensitivity is workable when installed at 6m mounting height. Only 10%, 25% sensitivity is not able to detect motion signal.
Settings
-
Sensitivity
Sensitivity can be adjusted by selecting the combination on the DIP switches for different applications.
-
Hold-time
Hold-time refers to the time period that the light remains 100% on if no more movement is detected.
-
Daylight sensor
Different daylight threshold can be preset on DIP switches. Light will always turn on upon movement if daylight sensor is disabled.
*Disable means the daylight sensor does not work. The sensor will turn on light once motion is detected regardless of ambient light level.
Trouble shooting:
Malfunction Cause Remedy | Cause | Remedy |
---|---|---|
The light will not come on | Incorrect light-control setting selected | Adjust |
daylight threshold setting
Faulty lamp| Replace lamp
No power supply| Check power to sensor
The lamp is always on| Continuous movement in the detection zone| Check
detection area setting
The lamp is on without any identifiable movement| The sensor is not mounted
for reliably detecting movement| Securely mount enclosure
Movement occurred, but not identified by the sensor (Movement behind wall,
movement of small object in immediate lamp vicinity etc.)|
- Reduce sensitivity.
- Check the movement behind walls to avoid facilities such as water pipe, fan, which may mis-trigger the sensor.
The lamp will not work despite movement| Rapid movements are being suppressed to minimize malfunctioning or the detection radius is too small.| Check detection area setting
Care and Safety
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive
cleaners as these could damage the finish.
For your safety, always switch off the power supply before cleaning.
For further information, please visit https://www.lighting-info.co.uk/95541
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is double insulated and does not require connection to an earth circuit.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge.
If you are in any doubt, please consult a qualified electrician.
This light fitting should be connected to a circuit with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note of the connections.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.
Technical data
Supply
Voltage : 220-240 V~, 50 Hz
Voltage :
Bulb
Type : 95541—-18/14/9W LED module (SMD) CCT, 3000/4000/6000K
103936—12/9/6W LED module (SMD) CCT, 3000/4000/6000K 103939—28/24/20W LED
module (SMD) CCT, 3000/4000/6000K
This product contains a light source of energy efficiency class D.
Non-replaceable light source
Replaceable control gear by a professional
Conformity with all relevant UKCA Directive requirements
Conformity with all relevant EC Directive requirements
The power supply is Double Insulated and does not require connection to an Earth circuit.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or local store for recycling advice.
This product is not suitable for dimming
This product is rated at IP65
This product is rated at IK10 for 95541, 103936.
This product is rated at IK08 for 103939.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between each light fitting.
Avoid locating any cables in positions that would cause a hazard. Position cables and junction boxes (not supplied) away from areas where they may be at risk from being cut, trapped or damaged.
The mains supply cable must have a minimum cross section area of 1.0mm2
Cables must be protected using suitable conduit or plastic trunking.
The products can be wall or ceiling mounted. If wall mounting ensure that the power supply is at the bottom.
Installation
Existing fittings must be completely removed before installation of a new product.
Before removing the existing fitting, carefully note the position of each set of wires.
Note the switch is turned off before installation.
The ceiling surface must be flat and smooth to ensure a good fit.
Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
- Twist and remove the lamp cover from the product, keep safe for refitting later.
- Turn the clip to loose the LED tray in the rear casing.
- Using the rear casing as a template mark the position to drill out the fixing holes. Take care to avoid damaging any concealed wiring and pipes.
- Fix the rear casing into the position using the installation plugs and screws.
- Pull the cable through the cable entry hole and seal to maintain the IP rating and wire as detailed Wiring Diagram.
- Refit the LED tray back into the rear casing and lock the clip.
- Twist the lamp cover back onto the product and lock in place
- Replace fuse or circuit breaker and switch on. Your light is now ready for use.
Replace fuse or circuit breaker and switch on. Your light is now ready for
use.
The wattage is changeable between the diffrent wattage using the wattage switch on the driver before installation.
For the 103936 is the 12W/9W/6W selectable
For the 95542 is the 18W/14W/9W selectable
For the 103939 is the 28W/24W/20W selectable
The colour is changeable between 3000/4000/6000K using the CCT switch on the driver before installation.
Choose your preferred wattage and colour before installing by wattage switch or CCT switch on the driver.
Note : Befeore you change the wattage or colour, please turn off the power switch for safety.
Bezels for 95541 only
The following individual casings are available for purchase separately
- 95545 : Chrome plain
- 95546 : White eyelid
- 95547 : White grill
- 95548 : Black plain
- 95549 : Black eyelid
- 95550 : Black grill
- 95551 : Anthracite grey plain
- 95552 : Anthracite grey eyelid
- 95553 : Anthracite grey grill
Wiring
Having correctly identified the wiring from your existing light fitting, pull
the mains wire through the hole and connect to the quick fit connection block
in the following way. No tools are necessary.
Check that…
- You have correctly identified the wires.
- The connections are tight.
- No loose strands have been left out of the connection block.