PolyScience 110-822 Refrigerated Circulator Instruction Manual

June 10, 2024
PolyScience

110-822 Refrigerated Circulatory
Instruction Manual

Safety Recommendations

WARNING:

  • This Circulating Bath is suitable for use with Class I non-flammable fluids only.
  • Be aware of chemical hazards that may be associated with the bath fluid used as well as those contained In the material safety data sheet.
  • Use only recommended bath fluids, see Technical Information in the instruction manual for recommended fluids. Always use fluids that satisfy safety. health, and equipment compatibility requirements.
  • Use only non-acid bath fluids.

WARNING:
When using hazardous bath fluids, the user must attach the following warning labels to the front of the unit so that they are well visible.
WARNING:

  • Always connect the power cord on this Circulatory to a grounded (3-prong) power outlet. Make certain that the outlet is the same voltage and frequency as your unit. The use of an extension cord is not recommended.
  • Never operate the Circulatory with a damaged power Cord.
  • Always turn the Circulatory OFF and disconnect mains power before performing any maintenance or service.

WARNING:

  • Never operate the Circulatory without bath fluid In the reservoir. Periodically check the reservoir to ensure that the liquid depth is within acceptable levels. Always refill the reservoir using the same bath fluid type that Is already in the reservoir. Bath oil must not contain any water contaminants and should be preheated to the actual bath temperature before adding as there Is an explosion hazard at high temperatures.
  • Always drain all fluid from the reservoir before moving or lifting your Circulatory. Be sure to follow your organization’s procedures and practices regarding the safe lifting and relocation of heavy objects.

WARNING:

It Is the user’s responsibility to properly decontaminate the unit in the event hazardous materials are spilled on exterior or interior surfaces. Consult manufacturer If there Is any doubt regarding the compatibility of decontamination or cleaning agents.
WARNING: Read the safety data sheet for the bath fluid being used before filling the reservoir. Always use fluids that satisfy safety, health, and equipment compatibility requirements.
WARNING: The use of an extension cord is not recommended.
WARNING:

  • Always allow the bath fluid to cool to ambient temperature before draining.
  • The reservoir cover, top deck, and/or external pump connections may become hot with continuous use. Exercise caution when touching these pads.
  • Always keep within the 85°C maximum operating temperature limit if using a bicarbonate tank.

General Safety Symbols

**** This symbol alerts you to a wide range of potential dangers.
**** This symbol advises you of danger from electricity or electric shock.
**** This symbol indicates that a hot surface may be present.
This symbol marks Information that is particularly important.
This symbol indicates alternating current.
These symbols on the Power Switch/Circuit Bleaker indicate that they place

the main power supply ON/OFF.
| This symbol on the Power Key indicates that it places the unit in a standby mode. R DOES NOT fully disconnect the unit from the PPM, supply.

Read all instructions pertaining to safety, set-up, and operation. Proper operation and maintenance is the user’s responsibility.

Circulating Bath Buick Start Guide

110-822 SD
This guide offers the quickest way to install and begin operating your Circulating Bath. It provides only the details necessary to get you up and running. Please refer to the instruction manual contained on the Resource Disk that came with your circulator for full operational information.

  1. Fill reservoir with fluid. PolyScience 110-822 Refrigerated Circulator - icon3

  2. Connect to grounded electrical power of the correct voltage.

  3. Turn Mains power ON.

  4. Turn Controller power ON.

  5. Adjust Safety Set temperature.
    Safety setting default is approximately 90°C.
    5a. Using a small flat blade screwdriver, rotate the Safety Thermostat clockwise until it stops. 5b. Press’
    5c. Touch the scroll bar until the displayed set point temperature is approximately 5° above the desired operating temperature.
    5d. Allow the bath fluid to stabilize at the desired Safety Set Temperature.
    5e. Slowly rotate the Safety Set temperature counter-clockwise until the OVER TEMP or LOW FLUID alarm message appears on the display and the alarm sounds.
    5f. Press to turn the Circulatory OFF. 5g. Allow bath to cool and then press the Safety Reset. 5h Press to turn the Circulatory ON.

  6. Enter temperature set point.
    6a Press then touch the scroll bar until the desired set point temperature is displayed.
    6b.  To accept. press’ or allow the LCD to return to the main operations

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals