EGO Osa1000 Olive Shaker Attachment Instruction Manual

June 4, 2024
EGO

EGO Logo Osa1000 Olive Shaker Attachment
Instruction Manual
EGO Osa1000 Olive Shaker
AttachmentEGO Osa1000 Olive Shaker Attachment - Fig
1EGO Osa1000 Olive Shaker Attachment -
Fig 2

READ ALL INSTRUCTIONS!
WARNING: Be sure to read and understand all safety instructions in this Operator’s Manual, including all safety alert symbols such as “WARNING,” and “CAUTION” before using this tool. Failure to follow all instructions listed below may result in electric shock, fire, and/or serious personal injury.
WARNING: The operation of any power tools can result in foreign objects being thrown into your eyes, which can result in severe eye damage. Before beginning power tool operation, always wear safety goggles or safety glasses with side shields and a full face shield when needed. We recommend a Wide Vision Safety Mask for use over eyeglasses or standard safety glasses with side shields.

SAFETY SYMBOLS

| Safety Alert| | WEEE, Waste electrical products should not be
disposed of with household waste
---|---|---|---
| To reduce the risk of injury, user must read
instruction manual| | Guaranteed sound power level according to the
European community’s Directive
| Keep bystanders away| V|  Volt
| Wear snug-fitting clothing. Do not wear a scarf, necktie, or jewelry| | Direct Current
| Wear non-slip safety footwear| BPM| Beats per Minute
**| Wear close-fitting safety glasses, earplugs, or ear muffs and a safety hard hat with a chin strap| IPX4|  Protection against ingress of water degree 4
| Wear heavy-duty work gloves made of durable material| | Keep sufficient distance away from electrical
power lines
| Do not expose to moisture| **
| Keep hands and feet away from the cutting tool
| This product is in accordance with applicable EC directives

CONNECTING THE OLIVE SHAKER ATTACHMENT TO THE POWER HEAD
This olive shaker attachment is designed for use with EGO 56V LITHIUM-ION Power Head PH1400E.
See the “INSTALLING AN ATTACHMENT TO THE POWER HEAD“ section in the power head PH1400E operator’s manual.
INSTALLING CARBON ROD

  1. Loosen the 5 fixing bolts on the comb with the Allen key respectively.
  2. Pass the 5 carbon rods through the 5 corresponding holes in the black shock absorber one by one. (Fig. C). Insert the carbon rods into each of the fixed holes corresponding to the comb and then press it to the bottom. (Fig. D)
  3. Tighten the 5 fixing bolts on the comb with the Allen key respectively.
  4. The other five-carbon rods are installed the same way.

WARNING: Never attach or adjust any attachment while the power head is running or with the battery installed.

OPERATION

WARNING: Do not allow familiarity with this product to make you careless.
CAUTION: Before each use, make sure you have pressed 10 carbon rods down to the very end. Inspect the entire product for damaged, missing, or loose parts such as screws, carbon rods, etc. Tighten securely all screws and do not operate this product until all missing or damaged parts are replaced.
APPLICATIONS
Intended use: You may use this product for the purpose of harvesting nuts and fruits. You may use EGO POWER HEAD to drive the 10 carbon rods of Olive Shaker’s working head to swing back and forth at high frequency, knocking the Olive fruit from the branches to the ground.
NOTICE: The tool is to be used only for its prescribed purpose. Any other use is deemed to be a case of misuse.
NOTICE: Keep children and bystanders away while operating a power tool.

SPECIFICATIONS

Olive shaker BPM 1780/2120 bpm
Forkhead stroke 350mm-600mm
Weight 2.1 kg

Measured sound power level L
WA| 90.1 dB(A)
K=1.97 dB(A)
Sound pressure level at
operator’s ear LpA| 70.1 dB(A)
K=3 dB(A)
Guaranteed sound power level LWA
(according to 2000/14/EC)| 92 dB(A)
Vibration ah| Front-assist Handle| 1.8 m/s2
K=1.5 m/s2
Rear Handle| 4.3 m/s2
K=1.5 m/s2

PACKING LIST

PART NAME QUANTITY
Olive shaker assembly 1
Carbon rod 10
Shock absorber 2
Bolt & Nut 10
Allen Key 1
Operator’s Manual 1

DESCRIPTION

KNOW YOUR OLIVE SHAKER ATTACHMENT (Fig. A)

  1. Carbon Rod
  2. Shock Absorber
  3. Comb
  4. Upper Piston Guard
  5. Tube

ASSEMBLY

WARNING: If any parts are damaged or missing, do not operate this product until the parts are replaced.
WARNING: Do not attempt to modify this product or create accessories not recommended for use with this olive shaker. Any such alteration or modification is misused and could result in a hazardous condition leading to possible serious personal injury.

PREPARATION FOR START
Notice: Wear non-slip gloves for maximum grip and protection. Never stand directly under the branch you are shaking. Make sure that you have a secure and balanced footing. Watch out for obstacles such as tree stumps, roots, and ditches, which could cause you to trip or stumble.
Notice: Maintain a proper grip on the unit whenever the motor is running. Hold the unit firmly with both hands.
Notice: Pay attention to the tree’s limb structure during operation. Do not be too close to the olive tree when you operate. It’s easy to get hurt if you get too close.
TO START/STOP THE TOOL
See the “STARTING/STOPPING THE POWER HEAD” section in the power head PH1400E operator’s manual.
BASIC HARVESTING PROCEDURE (Fig. B)

  1. Pay attention to the tree’s limb structure during operation:
    ◾ Comb the lower section (A) from the top downwards, this also applies to the outer branches of the tree that hang down.
    ◾ Comb the top part (B) upwards from the bottom.
    ◾ Comb from the inside of the tree to the top of the branch.

  2. While combing the branches, rotate the tube back and forth on axis (C) if necessary.

  3. Shake the whole tree even if there is very little fruit left on it.

  4. Do not fix the machine in one place for too long to avoid damaging unnecessary leaves and branches.

  5. Always switch off the machine when no one is on duty.

MAINTENANCE

WARNING: To prevent serious personal injury, remove the battery pack from the tool before servicing, cleaning, changing attachments, or removing material from the unit.
WARNING: When servicing, use only identical replacement parts. The use of any other parts can create a hazard or cause product damage. To ensure safety and reliability, all repairs, other than the items listed in these maintenance instructions, should be performed by a qualified service technician.
To assure a high performance for a long-time, the operator has to make simple maintenance work as mentioned in the following table.

POS. COMPONENT ACTION FREQUENCY
1 Carbon rods Check if assembled correctly Daily
2 Piston Grease through the proper opening 3 times a day
3 Olive Shaker Cleaning after use Daily

NOTE: The inside mechanisms of the olive shaker are protected for a lifetime with special grease. DO NOT OPEN THE MACHINE UPPER PART. Any tampering will invalidate the manufacturer’s warranty.
REPLACEMENT

  1. Loosen the 10 fixing bolts on the comb with the Allen key respectively.
  2. Hold the black shock absorber and pull the tine out outward, then 10 carbon rods be pulled out together. Replace the new tine or shock absorber directly, then insert it into the fixing hole on the comb and tighten the retaining bolt.
  3. If only one time is damaged, simply loosen the retaining bolt at the root of the time. Hold the black shock absorber with your hand, draw the damaged tine separately and pull it out.
    Pass the new tine through the black shock absorber, then insert it into the fixed hole corresponding to the comb. Press it to the bottom and simply re- tighten the retaining bolts. (Fig. E)

Protecting the environment
**** WEEE (Waste Electrical and Electronic Equipment)
Do not dispose of electrical equipment, used batteries, and chargers into household waste! Take this product to an authorized recycler and make it available for separate collection. Electric tools must be returned to an environmentally compatible recycling facility.

TROUBLESHOOTING

PROBLEM CAUSE SOLUTION
The olive shaker fails to start. ■ The battery pack is depleted. ■ Battery

pack breakdown
■ The battery pack is not properly attached to the power head
■ Beyond the above-mentioned reason still do not start.| ■ Charge the battery pack with a designated charger
■ Replace the battery pack with a new one
■ Check whether the battery pack is fully fastened
■ Do not disassemble and inspect the machine by yourself. Deliver it to the designated service point for repair
The sudden stop at work| ■ The battery pack flashes red
■ The battery pack flashes yellow
■ Olive shaker overload| ■ The electric quantity of the battery pack is too low. Please replace it with a new battery pack or recharge and use it again.
■ If the battery pack is too warm, cool it in a ventilated place for a while and then use it again. Please adjust the working mode to avoid continuous high-intensity use
■ Try tapping the olive fruit with the tip of the time. Do not insert the tine completely into the tree cluster.
■ Beyond the above-mentioned reason still do not start.| ■ Do not disassemble and inspect the machine by yourself. Deliver it to the designated service point for repair
Olive shaker is loud in vibration or noise| ■ Piston lack of lubrication
■ Tine break off
■ Drive link is abnormal
■ Gear is damaged
■ Driveshaft spline broke damaged| ■ Grease through the proper opening in the lower part of the head
■ Replace a new tine
■ Open the upper piston guard to check whether the drive link and related bearing connectors are
■ If all other parts are normal, then only the gear is damaged. Replace the gearbox component with a new one
■ Replace the tube components with a new ones.

WARRANTY
EGO WARRANTY POLICY
Please visit the website egopowerplus.com for full terms and conditions of the EGO Warranty policy

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals