EGO Osa1000 Olive Shaker Attachment Instruction Manual
- June 4, 2024
- EGO
Table of Contents
Osa1000 Olive Shaker Attachment
Instruction Manual
READ ALL INSTRUCTIONS!
WARNING: Be sure to read and understand all safety instructions in this
Operator’s Manual, including all safety alert symbols such as “WARNING,”
and “CAUTION” before using this tool. Failure to follow all instructions
listed below may result in electric shock, fire, and/or serious personal
injury.
WARNING: The operation of any power tools can result in foreign objects
being thrown into your eyes, which can result in severe eye damage. Before
beginning power tool operation, always wear safety goggles or safety glasses
with side shields and a full face shield when needed. We recommend a Wide
Vision Safety Mask for use over eyeglasses or standard safety glasses with
side shields.
SAFETY SYMBOLS
| Safety Alert| | WEEE, Waste electrical products should not be
disposed of with household waste
---|---|---|---
| To reduce the risk of injury, user must read
instruction manual| | Guaranteed sound power level according to the
European community’s Directive
| Keep bystanders away| V| Volt
| Wear snug-fitting clothing. Do not wear a scarf, necktie, or jewelry| |
Direct Current
| Wear non-slip safety footwear| BPM| Beats per Minute
**| Wear close-fitting safety glasses, earplugs, or ear muffs and a safety
hard hat with a chin strap| IPX4| Protection against ingress of water
degree 4
| Wear heavy-duty work gloves made of durable material| | Keep sufficient
distance away from electrical
power lines
| Do not expose to moisture| **| Keep hands and feet away from the cutting
tool
| This product is in accordance with applicable EC directives
CONNECTING THE OLIVE SHAKER ATTACHMENT TO THE POWER HEAD
This olive shaker attachment is designed for use with EGO 56V LITHIUM-ION
Power Head PH1400E.
See the “INSTALLING AN ATTACHMENT TO THE POWER HEAD“ section in the power head
PH1400E operator’s manual.
INSTALLING CARBON ROD
- Loosen the 5 fixing bolts on the comb with the Allen key respectively.
- Pass the 5 carbon rods through the 5 corresponding holes in the black shock absorber one by one. (Fig. C). Insert the carbon rods into each of the fixed holes corresponding to the comb and then press it to the bottom. (Fig. D)
- Tighten the 5 fixing bolts on the comb with the Allen key respectively.
- The other five-carbon rods are installed the same way.
WARNING: Never attach or adjust any attachment while the power head is running or with the battery installed.
OPERATION
WARNING: Do not allow familiarity with this product to make you careless.
CAUTION: Before each use, make sure you have pressed 10 carbon rods down
to the very end. Inspect the entire product for damaged, missing, or loose
parts such as screws, carbon rods, etc. Tighten securely all screws and do not
operate this product until all missing or damaged parts are replaced.
APPLICATIONS
Intended use: You may use this product for the purpose of harvesting nuts
and fruits. You may use EGO POWER HEAD to drive the 10 carbon rods of Olive
Shaker’s working head to swing back and forth at high frequency, knocking the
Olive fruit from the branches to the ground.
NOTICE: The tool is to be used only for its prescribed purpose. Any other
use is deemed to be a case of misuse.
NOTICE: Keep children and bystanders away while operating a power tool.
SPECIFICATIONS
Olive shaker BPM | 1780/2120 bpm |
---|---|
Forkhead stroke | 350mm-600mm |
Weight | 2.1 kg |
Measured sound power level L
WA| 90.1 dB(A)
K=1.97 dB(A)
Sound pressure level at
operator’s ear LpA| 70.1 dB(A)
K=3 dB(A)
Guaranteed sound power level LWA
(according to 2000/14/EC)| 92 dB(A)
Vibration ah| Front-assist Handle| 1.8 m/s2
K=1.5 m/s2
Rear Handle| 4.3 m/s2
K=1.5 m/s2
PACKING LIST
PART NAME | QUANTITY |
---|---|
Olive shaker assembly | 1 |
Carbon rod | 10 |
Shock absorber | 2 |
Bolt & Nut | 10 |
Allen Key | 1 |
Operator’s Manual | 1 |
DESCRIPTION
KNOW YOUR OLIVE SHAKER ATTACHMENT (Fig. A)
- Carbon Rod
- Shock Absorber
- Comb
- Upper Piston Guard
- Tube
ASSEMBLY
WARNING: If any parts are damaged or missing, do not operate this product
until the parts are replaced.
WARNING: Do not attempt to modify this product or create accessories not
recommended for use with this olive shaker. Any such alteration or
modification is misused and could result in a hazardous condition leading to
possible serious personal injury.
PREPARATION FOR START
Notice: Wear non-slip gloves for maximum grip and protection. Never stand
directly under the branch you are shaking. Make sure that you have a secure
and balanced footing. Watch out for obstacles such as tree stumps, roots, and
ditches, which could cause you to trip or stumble.
Notice: Maintain a proper grip on the unit whenever the motor is running.
Hold the unit firmly with both hands.
Notice: Pay attention to the tree’s limb structure during operation. Do
not be too close to the olive tree when you operate. It’s easy to get hurt if
you get too close.
TO START/STOP THE TOOL
See the “STARTING/STOPPING THE POWER HEAD” section in the power head PH1400E
operator’s manual.
BASIC HARVESTING PROCEDURE (Fig. B)
-
Pay attention to the tree’s limb structure during operation:
◾ Comb the lower section (A) from the top downwards, this also applies to the outer branches of the tree that hang down.
◾ Comb the top part (B) upwards from the bottom.
◾ Comb from the inside of the tree to the top of the branch. -
While combing the branches, rotate the tube back and forth on axis (C) if necessary.
-
Shake the whole tree even if there is very little fruit left on it.
-
Do not fix the machine in one place for too long to avoid damaging unnecessary leaves and branches.
-
Always switch off the machine when no one is on duty.
MAINTENANCE
WARNING: To prevent serious personal injury, remove the battery pack from
the tool before servicing, cleaning, changing attachments, or removing
material from the unit.
WARNING: When servicing, use only identical replacement parts. The use of
any other parts can create a hazard or cause product damage. To ensure safety
and reliability, all repairs, other than the items listed in these maintenance
instructions, should be performed by a qualified service technician.
To assure a high performance for a long-time, the operator has to make simple
maintenance work as mentioned in the following table.
POS. | COMPONENT | ACTION | FREQUENCY |
---|---|---|---|
1 | Carbon rods | Check if assembled correctly | Daily |
2 | Piston | Grease through the proper opening | 3 times a day |
3 | Olive Shaker | Cleaning after use | Daily |
NOTE: The inside mechanisms of the olive shaker are protected for a
lifetime with special grease. DO NOT OPEN THE MACHINE UPPER PART. Any
tampering will invalidate the manufacturer’s warranty.
REPLACEMENT
- Loosen the 10 fixing bolts on the comb with the Allen key respectively.
- Hold the black shock absorber and pull the tine out outward, then 10 carbon rods be pulled out together. Replace the new tine or shock absorber directly, then insert it into the fixing hole on the comb and tighten the retaining bolt.
- If only one time is damaged, simply loosen the retaining bolt at the root of the time. Hold the black shock absorber with your hand, draw the damaged tine separately and pull it out.
Pass the new tine through the black shock absorber, then insert it into the fixed hole corresponding to the comb. Press it to the bottom and simply re- tighten the retaining bolts. (Fig. E)
Protecting the environment
**** WEEE (Waste Electrical and Electronic Equipment)
Do not dispose of electrical equipment, used batteries, and chargers into
household waste! Take this product to an authorized recycler and make it
available for separate collection. Electric tools must be returned to an
environmentally compatible recycling facility.
TROUBLESHOOTING
PROBLEM | CAUSE | SOLUTION |
---|---|---|
The olive shaker fails to start. | ■ The battery pack is depleted. ■ Battery |
pack breakdown
■ The battery pack is not properly attached to the power head
■ Beyond the above-mentioned reason still do not start.| ■ Charge the battery
pack with a designated charger
■ Replace the battery pack with a new one
■ Check whether the battery pack is fully fastened
■ Do not disassemble and inspect the machine by yourself. Deliver it to the
designated service point for repair
The sudden stop at work| ■ The battery pack flashes red
■ The battery pack flashes yellow
■ Olive shaker overload| ■ The electric quantity of the battery pack is too
low. Please replace it with a new battery pack or recharge and use it again.
■ If the battery pack is too warm, cool it in a ventilated place for a while
and then use it again. Please adjust the working mode to avoid continuous
high-intensity use
■ Try tapping the olive fruit with the tip of the time. Do not insert the tine
completely into the tree cluster.
■ Beyond the above-mentioned reason still do not start.| ■ Do not disassemble
and inspect the machine by yourself. Deliver it to the designated service
point for repair
Olive shaker is loud in vibration or noise| ■ Piston lack of lubrication
■ Tine break off
■ Drive link is abnormal
■ Gear is damaged
■ Driveshaft spline broke damaged| ■ Grease through the proper opening in the
lower part of the head
■ Replace a new tine
■ Open the upper piston guard to check whether the drive link and related
bearing connectors are
■ If all other parts are normal, then only the gear is damaged. Replace the
gearbox component with a new one
■ Replace the tube components with a new ones.
WARRANTY
EGO WARRANTY POLICY
Please visit the website egopowerplus.com for full
terms and conditions of the EGO Warranty policy
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>