MILESEEY TR256B Handheld Thermal Camera User Manual
- June 11, 2024
- MILESEEY
Table of Contents
Handheld Thermal Camera
TR256B/TR256E
User Manual
Legal Disclaimer
The thermal cameras manufactured by Mileseey are warranted for a period of two-year and the accessories are warranted for a period of three-month form the delivery date of the original purchase, provided such products have been under normal storage, use and maintenance. This warranty extends only to the original purchaser and is not transferable. It is not applicable to any product which has be subjected to misuse, neglect, accident or abnormal conditions of operation. In the case of a defect in a product covered by this warranty the product must not be further used or maintained in order to prevent additional damage. The purchaser shall promptly report any defect to Mileseey or this warranty will not apply. Mileseey will, at its option, repair or replace any such defective product free of charge if, upon inspection, the product or accessories prove to be defective, the user can contact with after- sales service department of Mileseey within the said warranty period.
Safety Information
| Make sure you read all applicable Material Safety Data Sheets (SDS) and
warning labels on containers before you use a liquid. The liquids can be
dangerous. Injury to persons can occur.
---|---
| It is prohibited to use the product in a high temperature above 85 °C or in
a low temperature below-45 °C.
| It is forbidden to disassemble or refit the thermal camera at will.
| Do not use too long screws when installing the front/rear mounting bracket,
which may damage the thermal camera.
| No matter there is a lens cover or not, do not point the infrared thermal
camera towards strong light or equipment with laser radiation. This will
affect the accuracy of the thermal camera and even damage the detector in the
thermal camera.
| Do not use the product under conditions that doesn’ t match the
environmental requirements. For specific use environment requirements, see the
product parameter table.
| Do not apply solvents or equivalent liquids to the camera, the cables, or
other items.
| Be careful when you clean the infrared lenses. The lens has an anti-
reflective coating which is easily damaged. Damage to the infrared lens can
occur with too much force or cleaning with rough objects such as tissues.
Notice to user
- Accuracy
For very accurate results, we recommended that you wait 5 minutes after you have started the camera before measuring a temperature.
Technical Parameter
Model | TR256B | TR256E |
---|---|---|
Temperature range | -20°C—+550°C | -20°C—+350°C |
Temperature unit | °C / °F / K | °C/°F/K |
Temperature resolution | 0.1°C | 0.1°C |
Emissivity | 0.1-4.0 Adjustable | 0.1-1.0 Adjustable |
Display | 2.8LCD (320 x 240) | 2.8LCD (320 x 240) |
Temperature Alarm | LED flash/screen tip | LED flash/screen tip |
Accuracy | ±2°C/ ±2°C/±2% | ±2°C/ ±2% |
Response time | <10ms | <10ms |
IR resolution | 256 x 192 | 256 x 192 |
Digital Camera | I | x |
Visual Resolution | 200W | / |
Color Palette | White Hot,Black Hot,Iron, Lava,Rain Bow, RainBowHC, RdGy |
White Hot,Black Hot,Iron, Rain Bow
Image mode| I R,Fuse,P I P,Visble,Align ment| IR
Pixel size| 12pm| 12pm
Infrared spectral bandwidth| 8-14pm| 8-14pm
Field of view (FOV)| 56°X 42°| 56° x 42°
NETD| 40mK| 40mK
Focus Mode| focus-free| focus-free
Frame rate| 50hz| 50hz
PC software| Yes| Yes
Real-time image transmission| Yes| Yes
USB connection| U disk| U disk
Battery| 5000mah Li-ion battery 26650| 5000mah Li-ion battery 26650
Battery life| 12h| 12h
Charging time (Power off state)| 4 h| 4 h
Charging voltage/ current| 5V 1A or 5V 2A| 5V 1A or 5V 2A
Image storage| Micro SD Card| Micro SD Card
Transportation/ storage
environment| -20°C–60°C (-4°F-140°F) 10%-95% RH (non- condensing)| -20°C–60°C
(-4°F–140°F) 10%-95% RH (non-condensing)
Operating environment| -10°C-50°C| -10°C–50°C
IP rating| I P54| IP54
Drop test| 2M| 2M
Camera
-
Digital Camera (Only TR256B)
-
Infrared Lens
-
LED lamp
-
Trigger
-
Screen
-
Gallery button
Click to open the archive images -
Navigation button
Press up/down/left/right button to move the cursor among Menu, Settings and Gallery; Press the Center Button (Also called Confirm Button) to confirm. -
Power button
Long press to turn on/off -
Back button
Press to cancel operation or back to previous menu -
LED lamp
Long press to turn on/off the LED lamp -
USB Slot
Connect the power adapter to charge via USB cable Connect the computer to charge or transmit data via USB cable -
SD card
Standard microSD card, 16GB by default, support up to 32GB The microSD card can be taken out to transmit data to PC or other equipment with card readers
Quick Start Guide
-
Charging
• Please charge with 5V lA or 5V 2A power adapter and USB cable.
• You can connect the PC with the USB cable to charge the device.
• Open the protective cover on the top of the device, and charge the device by connecting the USB Type-C connector with the PC or adapter via data cable. -
Power on
Long press the power button to turn on. -
Point the camera at the object you are interested in
-
Image Capture
Click the trigger to capture the image. -
PC analysis
Download the client software, start client, import the data to perform the secondary analysis via USB cable or SD card.
1.Main toolbar measurement mode, image mode, color palette and settings can be set. 2.Secondary toolbar detailed options can be set here, such as selecting color palette.
-
Main toolbar
measurement mode, image mode, color palette and settings can be set. -
Secondary toolbar
detailed options can be set here, such as selecting color palette. -
Temperature measurement spot
it is divided into center spot, Max. temperature / Min. temperature spot tracing, closing thermographic spot, custom thermographic spot. -
Central spot temperature
display the temperature of the central spot. -
Date and time
display date and time. -
Battery Capacity
display the remaining battery capacity. -
Temperature range
display the temperature range in the current image.
Operating Instructions
Power On & Off
- In the shutdown status, long press the power button to turn on.
- In the power-on status, long press the power button to turn off.
- If the device crashes, you can shut it down by pressing and holding the power button.
Saving Images
- In the auto save mode, click the trigger to save the picture automatically.
- In the manual mode, click the trigger, then manually save images or cancel saving.
- The 16G SD card can save about 70, 000 images.
Note: the auto/manual mode can be switched in the “Settings -auto save” option.
View / Delete Pictures
When you take and save a picture, it will be stored in SD card, you can view
the saved image at any time as follows:
- Click the View Memory button to enter the library.
- Use the direction button to select the picture you want to view.
- Press confirm button to view the picture in full screen.
- Click the View Memory button or the return button continuously to return to the thermal imaging interface.
Center Spot Temperature Measurement
You can use point temperature measurement for temperature measurement. The
measurement results will be displayed in the upper left corner of the screen,
see Section 3.4.
- In the thermal imaging interface, press the center button to display the main toolbar.
- Select the measurement icon on the toolbar, and press the center button to bring up the secondary toolbar.
- Select “Center Point” icon on the secondary menu, and press the center button to enable the Center point temperature measurement(on by default), the temperature of the center point will be displayed in the upper left corner of the screen.
Cold/Hot Spot Tracing
You can turn on cold point / hot spot tracking to identify the lowest/highest
temperature on the screen by checking the moving cursor:
- In the thermal imaging interface, click center button to display the main toolbar.
- Select the measurement icon on the toolbar, and press the center button to bring up the secondary toolbar.
- Select “High Temperature” or “Low Temperature” icon on the secondary menu, and press the confirm button to enable tracking of high/low temperature point.
User-defined Spot Measurement
- In the thermal imaging interface, click center button to display the main toolbar.
- Select the measurement icon on the toolbar, and press the center button to bring up the secondary toolbar.
- In the toolbar, select the “User-defined Spot 1” option. The spot can be moved by the navigation key in the thermal imaging interface. Click the center button to confirm the placement, and the return button to cancel the placement. Select the “User-defined Spot 1” again to turn off the spot display. “User-defined Spot 2” and “User-defined Spot 3” can be set in the same way.
Image Mode
Imaging Mode Introduction
- Thermal image: Infrared images only(TR256E only in this mode)
- Fusion: Fusion of infrared image and visual image in a certain scale. In the main interface, you can use the left and right navigation keys to adjust the fusion ratio of infrared and visible light.
- PIP(Picture in Picture):Thermal image is overlaid on the center of visual camera image.
- Digital Camera:Visual camera image only
Note: In order to achieve better overlay image effect, when using the picture in picture, and thermal fusion modes, you need to set the alignment distance, which is the approximate distance from the thermal camera to the target. In picture in picture/thermal fusion / digital camera mode, please make sure that the thermal image displayed on the screen is aligned with the target.
Steps of Changing Image Modes
- In the thermal imaging interface, press the center button to display the main toolbar
- select the “Image Mode” icon on the toolbar, and press the center button to bring up the secondary toolbar
- Select the image mode you need on the secondary toolbar and press the confirm button to switch into the selected image mode.
Color Palettes
You can change the color palette to distinguish temperature difference on the
thermal camera. A appropriate color palette can help you analyze images more
easily.
- In the thermal imaging interface, press the center button to display the main toolbar
- Select the “Color Palette” icon on the toolbar, and press the center button to bring up the secondary toolbar
- You can select a new palette and press the center button to switch into the selected palette.
Shutter Correction
Shutter Correction Introduction
Shutter correction is used to compensate for the non-uniformity of the
detector pixels or the non-uniformity caused by other optical interference.
When the picture effect is poor, you can perform shutter correction, which is
common in situations where the ambient temperature changes rapidly.
Shutter Correction Operation
In the imaging interface, click the return button to perform a non-uniformity
correction. During shutter correction, the screen will freeze for a short
time, which is normal.
Settings
Setting Emissivity
In order to get more accurate measurement results, you need to set the
emissivity according to the target to be measured before each measurement,
instead of using the default configuration. Emissivity refers to the ratio of
the radiation ability of an object to that of a blackbody at the same
temperature, which is relative to the reflectivity of the object. The lower
the emissivity, the higher the percentage of energy reflected, and the higher
the emissivity, the lower the percentage of energy reflected. For example,
human skin emissivity is 0.98 and printed circuit board emissivity is 0.91.
For more emissivity information, you can refer to the quick start guide in the
package or inquire from other ways.
Emissivity Setting
- In the thermal imaging interface, press the center button to display the main toolbar.
- select the “Settings” icon on the toolbar, and press the center button to enter the settings menu.
Setting Ambient Temperature
- In the thermal imaging interface, press the center button to display the main toolbar
- Select the “Settings” icon on the toolbar, and press the center button to enter the settings menu.
- Select “measurement parameters” in the list, press the confirm key, and then select “ambient temperature” to set ambient temperature.
Setting Distance
Different distances will have different effects on the measurement results.
For accurate temperature measurement, the distance information of the object
is necessary for compensating for the result.
- In the thermal imaging interface, click the OK button, and the main menu toolbar will be displayed.
- In the toolbar, select the “Settings” option and click the OK button to enter “Settings”.
- Select “measurement” in the list, click the confirm button, and then select “distance” to set the distance.
Temperature Unit
The camera supports temperature displays in degrees Celsius, Fahrenheit, and
Kelvin.
High/Low Temperature Alarm
The camera supports the high and low temperature alarm function. The user can
set the high and low temperature alarm threshold. The alarm function can be
turned on or off by setting the “on” and “off” options. After the high and low
temperature alarm is triggered, a prompt icon will appear on the screen. If
the “LED alarm” option is turned on, the LED light will flash promptly when an
alarm occurs.
For alarm snapshot function, you can set the alarm snapshot time interval and
the number of photos taken. Turn on this function, after triggering the high
and low temperature alarm, it will take pictures according to the set time
interval. When the set number of pictures is reached, the camera will stop
taking photos and this function will be turned off automatically. It needs to
be turned on again when it is used.
Automatically Save Photos
Turn on this function, the picture will be automatically saved after taking a
picture.
Timed Photo
The camera supports the function of taking pictures at regular intervals, and
users can independently set the time interval and number of pictures taken. If
this function is turned on, photos will be taken at the set time interval.
After the set number of photos is reached, the camera will stop taking photos
and this function will be automatically turned off.
Temperature Measurement Gear
The temperature measurement range of the equipment is -20-550°C. In order to
ensure the imaging effect and temperature measurement range, the temperature
measurement range is divided into -20-150°C and 100-550°C. Users can choose
different temperature measurement ranges independently according to the
application conditions.
System Settings
In system settings, you can view the relevant information of this camera, and
perform operations such as restoring factory default settings and formatting
the SD card. In the “USB Mode” option, the default is U-disk mode, and the
computer can directly access the SD card in the device through the USB cable.
the option of “USB Camera” is provided in some models, which can synchronize
the picture in the camera to the PC software for real-time display and
analysis.
Application Scenarios
Warehouse Detecting
With the help of C series handheld thermal camera, warehouse inspection
personnel can quickly find abnormal high temperature objects in the warehouse,
and take corresponding measures to eliminate potential safety hazards timely.
Detecting of Power Distribution Cabinet
The temperature distribution of power distribution equipment can directly
reflect the running status of the equipment. Improper contact or damage may
cause abnormal high temperature. The inspection personnel can detect anomalies
in time to ensure the safety of power distribution equipment. Detecting of
Heating Wire of Rear Car Window
The heating wire on the rear car window can defrost and defog to ensure the
safety of driving, especially on rainy and snowy days. The whole on-off
condition of the heating wire can not be seen through visible light. The whole
heating wire can be quickly detected by TR256 series handheld thermal camera
to analyze whether the heating wire is broken. HVAC Detecting
TR256 series handheld thermal camera can help HVAC engineers to fully capture
the temperature distribution of the measured pipeline, quickly find abnormal
points, make accurate judgment and positioning, effectively avoid the economic
loss caused by disassembly, and at the same time improve service quality and
enhance customer satisfaction.
FAQ
1. There is a big difference between the measured temperature and the actual temperature.
– Solutions: set the correct emissivity; the actual distance should be consistent with the set distance.
2. The client software can not be connected and the real-time image can not be previewed.
– Possible causes: the USB mode has not been successfully set.
– Solutions: change the USB mode to USB camera mode.
3.The measured temperature is abnormal if the target temperature is above 150°C.
– Possible causes: the temperature measurement mode has not been changed.
– Solutions: choose the corresponding temperature measurement mode for
different targets.
4.The camera will shut down automatically if it is not operated for a long time.
– Possible causes: the auto power-off is enabled.
– Solutions: you can choose 5min, 10min, 20min and auto power-off disabled
according to your actual need.
Cleaning Thermal Camera
Cleaning Camera Housing, Cables and Other Items
Liquids| One of the following liquids can be used.
1. Warm water
2. A Weak detergent solution
---|---
Cleaning Tools| A soft cloth
Cleaning Procedure| Please follow this procedure:
1.Soak a soft cloth in the liquid.
2.Twist the cloth to remove excess liquid.
3.Clean the camera parts with the cloth.
Do not apply solvents or similar liquids to the camera, the cables, or other
items. This can cause damage.
Cleaning Infrared Lens
Liquids| One of the following liquids can be used.
1.Commercial lens cleaning liquid with more than 30% is opropyl alcohol.
2.96% ethyl alcohol(C2H5OH).
---|---
Cleaning Tools| cotton wool
Cleaning Procedure| Please follow this procedure:
1.Soak the cotton wool in the liquid.
2.Twist the cotton wool to remove the excess liquid.
3.Clean the lens one time only and discard the cotton wool.
Do not clean the infrared lens too vigorously. This can damage the anti- reflective coating.
Contact Us
Shenzhen Mileseey Technology Co., LTD.
Website: www.mileseeytools.com
Email: service@mileseey.com.
MILESEEY has started researching and development manufacturer of quality
optical products including Golf rangefinder, laser measure device and
binoculars since 2009.
Focus on the development, researching, and manufacturing for over 13 years.
We strive to provide you with premium qualified products and satisfying
customer service to make your life easier and smarter.
Warranty
30-Day return and refund guarantee, 12-Month warranty, lifetime technique
support by MILESEEY.
Please feel free to reach us with any concerns,
Email: service@mileseey.com.
We strive to reply to you within 24hours.
Shenzhen Mileseey Technology Co., Ltd.
No.3601 Block A, Tanglang Town Plaza West,Fuguang
Community,Taoyuan Street,Nanshan District,Shenzhen,China
Web: www.mileseeytools.com
E-mail: service@mileseey.com
Made in China
Read User Manual Online (PDF format)