EXOR eX705 Industrial HMI PLC 5 Inch Display Installation Guide
- June 11, 2024
- EXOR
Table of Contents
- DIMENSION-CUT OUT
- FIXING BRACKET
- REAR VIEW
- POWER SUPPL
- CONNECTIONS
- EXPANSION SLOT FOR PLUG-IN MODULES
- DISPOSE OF BATTERIES
- STANDARDS AND APPROVALS
- SPECIAL INSTRUCTION FOR USE
- PRODUCT IDENTIFICATION
- OPTIONAL PLUGIN MODULE
- PRODUCT IDENTIFICATION
- INSTALLATION PROCEDURE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EXOR eX705 Industrial HMI PLC 5 Inch Display Installation Guide
DIMENSION-CUT OUT
CSD = 150mm/5.91” = Minimum Compass Safe Distance of standard compass/ Minimaler Kompass Sicherheitsabstand von Standardkompass
CSD2 = 100mm/3.94” = Minimum Compass Safe Distance of steering compass, standby steering compass, emergency compass/ Minimaler Kompass Sicherheitsabstand von Lenkkompass, Standby-Lenkkompass, Notkompass
FIXING BRACKET
A. eX705
B. Installation cut-out/ Einbauausschnitt
4 pieces/ Stücke
Tightening torque: 130Ncm or screw each fixing screw until the bezel corner gets in contact with the panel.
REAR VIEW
Description
- USB port V2.0, max. 500 mA
- Power
- Serial Port
- Ethernet Port 0 (10/100 Mb)
- Ethernet port 1 (10/100/1000 Mb)
- Expansion slots for plugin modules
- SD Card Slot
*for maintenance only
**** All ports are SELV (Safety Extra – Low Voltage) according European Standards and Class 2 according UL Standards
WARNING – EXPLOSION HAZARD – (Ethernet, USB connectors, memory card slot) DO NOT CONNECT OR DISCONNECT UNLESS THE POWER HAS BEEN DISCONNECTED OR THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS
**** Don’t open the panel rear cover when the power supply is applied.
POWER SUPPL
**** Extra low voltage power supply
DC Power Connector, Female – R/C Terminal Blocks (XCFR2), manufactured by Weid muller Inc., Cat. No. BLZ 5.08, torque 4.5 lb-in
**** Do not open the cabinet while the system is powered up.
The unit must always be grounded to earth with 1.5mmq wire size minimum. Earth
connection will have to be done using either the screw or the faston terminal
located near the power supply terminal block. Also connect to ground the
terminal 3 on the power supply terminal block. All the electronic devices in
the control system must be properly grounded. Grounding must be performed
according to applicable regulations
**** Ensure that the power supply has enough power capacity for the operation of the equipment
CONNECTIONS
PIN | Description |
---|---|
1 | RX/CHB- |
2 | TX/CHA- |
3 | CTS/CHB+ |
4 | RTS/CHA+ |
5 | +5V output |
6 | GND |
8 | SHIELD |
To operate in RS-485 pins 1-2 and 4-3 must be connected externally
EXPANSION SLOT FOR PLUG-IN MODULES
The validity of UL certification is ensured only by using accessories (PLxx) covered by the same certificate.
DISPOSE OF BATTERIES
These devices are equipped with rechargeable Lithium battery, not user- replaceable.
**** Dispose of batteries according to local regulations
This device cannot be disposed of as a domestic waste but according to WEEE
European Directive 2012/19/EU
USAGE IN EXPLOSION-HAZARDOUS AREAS ZONE 2 AND ZONE 22
**** The connection and installation have to be done in conformity with ATEX Directive, IEC EN 60079-14, and have to be performed by authorized, qualified personnel and in possession of necessary skills
**** Confirm that the location is free from explosively hazardous gases or dust before connecting or disconnecting equipment, replacing or wiring modules. Confirmthat the power supply has been turned OFF before disconnecting, replacing or wiring modules
**** Before turning ON, clean the front panel of the graphic panel with a damp cloth to avoid any electrostatic discharge
**** The graphic panel must not be exposed to direct sunlight.
**** End User is responsible to ensure that the maximum operating temperature is not exceeded in the end use application.
**** Ensure that the labelling specifications are compatible with the conditions permitted for the hazardous area at the site where it is being used (Zones 2/22 Group II: Surface industries
ATEX markings, apllied to the Models eX705:
DEMKO 17 ATEX 1871X / UL22UKEX2726X
Type examination certificate number: / Baumusterprüfbescheinigung Nummer:
**** DO NOT DISCONNECT WHILE CIRCUIT IS LIVE
IECEx markings, apllied to the Model / IECEx-Kennzeichnung, aplied der Modelle: eX705
Type examination certificate number/Baumusterprüfbescheinigung Nummer
The products have been designed for use in an industrial environment in compliance with the 2014/30/EU directive
Software available in these products is based on OpenSource. Visit oss.exorint.net for more details
EN 61000-6-4 | EN 61000-4-3 |
---|---|
EN 61000-6-2 | EN 61000-4-4 |
EN 60945 | EN 61000-4-5 |
EN 60079-0 | EN 61000-4-6 |
EN 60079-7 | EN 61000-4-8 |
EN 60079-31 | EN 61000-4-11 |
EN 61000-4-2 | EN 61000-4-29 |
Equipment group II, category 3 intended for use in potentially explosive atmospheres zones 2/22, G:gas and D:dust
The installation of these devices into the residential, commercial and light- industrial envi- ronments is allowed only in the case that special measures are taken in order to get the conformity to IEC-61000-6.3.
WARNING – Power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods, Article 501.10 (B) of the National Electrical Code, NFPA 70 for installation in the U.S., or as specified in Section 18-1J2 of Canadian Electrical Code for installations within Canada and in accordance with the authority having jurisdictions.
A. WARNING – EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENT MAY IMPAIR
SUITABILITY FOR CLASS I, DIVISION 2
B. WARNING – EXPLOSION HAZARD – WHEN IN HAZARDOUS LOCATIONS, TURN OFF
POWER BEFORE REPLACING OR WIRING MODULES, and
C. WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT WHILE THE
CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOW TO BE FREE OF IGNITABLE
CONCENTRATIONS.
D. SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D
HAZARDOUS LOCATIONS, OR NONHAZARDOUS LOCATIONS ONLY.
E. WARNING – EXPLOSION HAZARD – DO NOT CHANGE BATTERY UNLESS THE AREA IS
KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS
F. This equipment, except for the front panel display, is an open-type
device and is required to be installed in an enclosure suitable for the
environment such that the internal part of the equipment is only accessible
with the use of a tool.
STANDARDS AND APPROVALS
IECEx: IECEx: IECEx ULD 17.0019X
IEC 60079-0: Ex ec IIC T5…T4 Gc 0°C≤Tamb≤+50°C or -20°C≤Tamb≤+60°C
IEC 60079-7: Ex tc IIIC T95°C D
IEC 60079-31:
ATEX; DEMKO 17 ATEX 1871X / UL22UKEX2726X
EN 60079-0: II 3G Ex ec IIC T5…T4 Gc 0°C≤Tamb≤+50°C or-20°C≤Tamb≤+60°C
EN IEC 60079-7 + A1: II 3D Ex tc IIIC T95°C D
SPECIAL INSTRUCTION FOR USE
- For EPL Gc,
- the equipment shall only be used in an area of at least pollution degree 2, as defined in IEC/ EN 60664-1.
- the equipment shall be installed through an end-equipment enclosure that provides a minimum ingress protection of IP54 in accordance with IEC/EN 60079-0, suitable for applicable Gas Group, Temperature Classification and Ambient temperature range; and
- transient protection shall be provided that is set at a level not exceeding 140% of the peak rated voltage value at the supply terminals to the equipment.
- For EPL Dc, the equipment shall be installed through an end-eqipment enclosure that provides a minimum ingress protection of IP6X in accordance with IEC/EN 60079-0, suitable for applicable Dust Group, Temperature Classification and Ambient temperature range.
- Care shall be taken not to allow layers of dust to form on the graphic panel in a way that might cause the accumulation of static charges.
- eX700 series have only been evaluated for low risk of mechanical impact.
The relation between maximum ambient temperature and the assigned temperature class is as follow:
Maximum Ambient Temperature Range | Temperature Class |
---|---|
20°C up to 60°C | T4 |
0°C up to 50°C | T5 |
PRODUCT IDENTIFICATION
The product may be identified through a plate attached to the rear cover. You
will have to know the type of unit you are using for correct usage of the
information contained in the guide. An example of this plate is shown in the
figure below:
product model name: eX705
product part number: EX705U5P1
year/week of production: 1816
serial number: AA00011FR000000561AA
version id of the product: 121004B0220100
manufacturer address and: Exor International S.p.A.
read instruction warning: Via Monte Fiorino 9-13
IT-37057 San Giovanni Lupatoto (VR)
ATEX Marking
DEMKO 17 ATEX 1871X / UL22UKEX2726X
II 3G Ex ec IIC T5…T4 Gc 0°C≤Tamb≤+50°C or -20°C≤Tamb≤+60°C
II 3D Ex tc IIIC T95°C Dc
IECEx Marking
IECEx: IECEx ULD 17.0019X
Ex ec IIC T5…T4 Gc 0°C≤Tamb≤+50°C or -20°C≤Tamb≤+60°C
Ex tc IIIC T95°C Dc
OPTIONAL PLUGIN MODULE
The panels have several optional plugin module, multiple modules configurations are possible.
Slot #2 is available only if plugin module has the “bus extension connector”./
Each slot carries two communication channels:
- 1 serial interface
- 1 CAN interface
- 1 SPI interface
- 1 2G/3G interface
Note : It is not possible to stack two modules that are using the same type of interface.
PRODUCT IDENTIFICATION
Note: the PLCM01 label is used as an example for PLCM01, PLCM05, PLCM09X, PLIO03
product model name PLCM01
product part number PLCM01U0P1
year/week of production 2243
serial number AA0000225000000561AA
version id of the product 050100A00000000
manufacturer address and read Exor International S.p.A.
instruction warning Via Monte Fiorino 9-13 IT-37057 San Giovanni Lupatoto (VR)
INSTALLATION PROCEDURE
| Application| Max Modules| Bus Extension connector
---|---|---|---
PLCM01| CAN| 1| Y
PLCM01-NE| CAN| 1| N
PLCM05| CODESYS License| 1| Y
PLCM09X| 3G Modem| 1| Y
PLIO03| Multifunction I/O| 1| N
PLCM01 / PLCM01-NE Operating temperature -20°C to 60°C
PLCM05 Operating temperature -20°C to 60°C
PLCM09X Operating temperature -20°C to 60°C
PLIO03 with part number PLIO03xxxxY where:
- Y≤2 is operating temperature range 0°C≤Tamb≤+50°C with Operating Temperature Code T5 (vertical installation), 12-30VDC
- Y>2 is operating temperature range –20°C≤Tamb≤+60°C with Operating Temperature Code T4 (vertical installation), 12-30VDC
Note the above different “Operating Temperature Code” for different part number of PLIO03 module.
PLCM and PLIO03 electrical ratings:
- PLCM01: For electrical rating refers to the host eX700 models.
- PLCM05: For electrical rating refers to the host eX700 models and PLIO03 ratings
- PLCM09X: 2xDigital Inputs voltage 12÷30 Vdc, 3mA; 2xDigital Outputs voltage 12÷30 Vdc, 0.5A
- PLIO03: 20xDigital Inputs voltage 12÷30 Vdc; 12xDigital Outputs voltage 12÷30 Vdc, 0.5A; 4xAnalog inputs 0÷10 Vdc, 4-20mA; 4xAnalog outputs: 0÷10 Vdc, 4-20mA
Reproduction of the contents of this copyrighted document, in whole or part, without written permission of Exor International S.p.A., is prohibited. Dieses Dokument ist urheberrechtlich geschützt. Das vervielfältigen in Auszügen oder im Ganzen darf nicht ohne die schriftliche Zustimmung von Exor International S. p. A. vorgenommen werden.
User Manual available on/ Benutzerhandbuch verfügbar auf www.exorint.com
MANEX705U002 V.1.07 20.12.2022
© 2018-2022 Exor International S.p.A
Exor International S.p.A. – San Giovanni Lupatoto VR, Italy
www.exorint.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>