CSF-4004 Pressure Balanced 3 Function Wall Mount Shower System
“`html
Specifications
- Dimensions: Various critical dimensions detailed in mm
- Parts List: Detailed list of components included
Product Usage Instructions
Before Installation
Make sure to read the installation guide thoroughly to prevent
personal injury or product failure. Contact customer service for
assistance.
Installation
-
It is recommended to have a licensed plumber install the
unit. -
Read the instructions carefully and gather all necessary tools
and supplies. -
Flush the water system before installation.
Cleaning and Care
Regularly clean the faucet with a soft cloth. For heavy
cleaning, mild liquid detergents can be used. Avoid abrasive
cleaners as they may damage the finish.
Tools Needed
- Plumbers Tape
- Safety Glasses
- Phillips Screwdriver
- Wrench
- Silicone Sealant
Installation Schematics
Detailed placement instructions for shower and tub components
are provided. Follow the specified measurements for proper
installation.
Frequently Asked Questions (FAQ)
Q: Can I install the Halo CSF-4004 unit myself?
A: It is recommended to have a licensed plumber install the unit
to ensure proper installation and to avoid any issues.
Q: What should I do if I encounter missing parts during
installation?
A: Contact customer service at CASA FIXTURE VOLUME-C for
assistance with any missing parts or assembly questions.
Q: How should I clean the faucet to maintain its
appearance?
A: Use a soft cloth for regular cleaning and mild liquid
detergents for heavier cleaning. Avoid abrasive cleaners that may
damage the finish.
“`
Installation Guide
Halo CSF-4004
Before Installation
CAUTION
Failure to read these instructions prior to installation may result in
personal injury, property damage, or product failure. Manufacturer assumes no
responsibility for product failure due to improper installation.
DO NOT RETURN TO STORE
If you have any trouble, contact us before reaching out to the retailer. we’ll
make it right. Our customer service team will be glad to assist you with any
assembly, missing part or questions that you may have about your products.
Contact CASA FIXTURE VOLUME-C
833-888-8223
PRIOR TO INSTALLATION
1- For best results, we recommends that this unit be installed by a licensed,
professional plumber. 2- Please read over these instructions thoroughly before
beginning installation. Make sure that you have all
tools and supplies needed to complete the installation. 3- Please flush the
water system to ensure that no metal swarf, solder, and other impurities can
enter the
faucet that might damage the cartirdge. (Most of the leakages and water flow
issues are from avoilding this very necessary step). 4- Turn off the hot and
cold water lines at the angle valve and turn on the old faucet to release any
built-up pressure. 5- Keep this booklet and the receipt (or other proof of
date and place of purchase) for this product in a safe place. The receipt is
required should it be necessary to request warranty parts. 6- Please keep the
box and packaging materials until your product is completely installed and
functional.
Cleaning and Care
Clean the faucet often with a soft cloth to keep it looking like new. For
heavy cleaning you can use mild liquid detergents or non-abrasive liquid
polisher. Rinse with water and dry with a soft cloth. Avoid abrasive cleaners,
steel wool and harsh chemicals as these will dull the finish and void your
warranty.
Tools you may need
Plumbers Tape
Safety Glasses
Phillips Screwdriver
Wrench
Silicone sealant
Installation Schematics
Min. 78″(1981mm) Max. 94″(2387mm)
Min. 48″(1219mm) Max. 59″(1498mm)
Shower Only: Min. 45″(1143mm) Max. 48″(1219mm)
With Tub: Min. 32″(813mm) Max. 42″(1067mm)
Min. 23″(584mm) Max. 26″(661mm)
Installation Schematics Measuring for Ideal Tub/Shower Performance
Installation of this product at non-recommended measurements may lead to
issues such as water discharge from the showerhead during tub fill mode.
Tub/Shower Position the valve body 32-42 inches from the floor of the tub
basin. (Follow valve instruction for proper valve body installation).
Shower Only Position the valve body 45-48 inches from the floor of the tub
basin. (Follow valve instruction for proper valve body installation).
The shower arm should be placed 78-94 inches above the floor of the tub basin.
(Follow shower arm instruction for proper threaded adapter installation).
The hand shower should be placed 48-59 inches above the floor. (Follow hand
shower holder instruction for proper threaded adapter installation).
The tub spout should be placed 23-26 inches above the floor. (Follow tub spout
instruction for proper threaded adapter installation).
Dimensions
Critical dimensions show in mm
Five 1/2 in. MNPT
4 1/4″ (107 mm)
2 11/16 ” (68 mm) 1 3/4 ” (45 mm)
6 1/8″ (155 mm) 1 1/2 ” (38 mm)
2 13/16 ” (72 mm)
5 3/8 ” (136 mm)
5/8 ” (16 mm)
1 9/16 ” (40 mm)
3 1/16 ” (78 mm)
4 3/16 ” (106 mm)
1/2 MNPT
2 3/8″ (60 mm)
7 1/16″ (180 mm)
2 3/16″ (55 mm)
2 3/8″ (60 mm)
15 3/4″ (400 mm)
1 3/4″ – 3″ (45-75 mm)
1/2 MNPT
9 13/16″ (250 mm)
3 1/8″ (80 mm)
7 7/8″ (200 mm)
1/2 MNPT 1/2 FNPT
Parts List
Shower Head
Escutcheon
Shower Arm
Hand Shower
Trim Plate
Decorative Tub Assembly
Escutcheon
Decorative Tub
Gear Cipher Adapter
Diverter Handle
Cover
Handle
Quick Connect for Supply Elbow
Supply Elbow with HandShower Holder
Set Screws for Supply Elbow
Mounting Screws for Shower Valve
Shower Hose Escutcheon
Bath Spout
Diverter Cartridge Retaining Nut
Rough-in Box and Screws Mudguards
Check Valves
Pressure Balaning Cartridge
Retaining Nut
Valve Installation Instructions
1
Finished wall
SHUT OFF WATER SUPPLIES. Consider the type and thickness of your finished wall before placing your stringer back plate.
Flush with the finished wall
2
Install the body so the surface of the finished wall is flush with the front of the rough-in box. Make
sure the word “UP” are on top of the valve body
when installing.
3A
Hot
Connect the valve body to water supplies using
proper fittings (copper tubing, iron pipe or PEX).
Note: For PEX, be sure to use the right fitting
for crimping and the right tool for cold
expansion.
If any of the three outlet ports is to be unused,
seal the port with a pipe plug.
Note: Left is the hot inlet port and right is the
cold inlet port.
If you are making a back-to-back or reverse
installation (hot on the right and the cold on left)
install the valve body as described, but the water
supply lines will be reversed.
Note: Right is the hot inlet port and left is the
Cold
cold inlet port.
Valve Installation Instructions
3B For 1/2″ Copper Tube Soldering
Solder water supply tube to the valve body. Note: Prior to soldering remove check stops, pressure balancing cartridge and diverter cartridge. Remove check stops by loosening hex nut counterclockwise. Remove the pressure balancing cartridge and diverter cartridge by unscrewing retaining nut with an adjustable wrench. Avoid soldering excessively at high temperature.
4 Flushing
Remove two round mudguards by turning counterclosewise. Remove the rough-in box.
5 Flushing
Remove pressure balancing cartridge by unscrewing retaining nut with an adjustable wrench. Slowly turn on both hot and cold supplies and flush out the valve body and lines. Close the check stops and reinstall the cartridge.
Valve Installation Instructions
6 Pressure Testing
With both check stops in the fully OPEN position, turn on cold and hot water supplies and conduct a system water pressure leak test. Note: To protect the valve, keep mudguards and rough-in box on during installation. Remove only when you are ready to install trims.
Open Close
Open Close
7
Use the rough-in box as a template to cut the wall properly.
8
Reinstall rough-in box , two round mudguards by turning clockwise and complete the wall finish
installation.
Note: In keeping with standard plumbing
practices it is essential that all tub/shower
systems be tested extensively for leaks before
the finishing wall, (tile, etc.) is completed.
Also ensure that the check stops are exposed,
(not covered by tile, boarding etc.) under the
removable trim plate. The trim plate should
completely cover the rough-in opening when
attached. (Having access to these stops allow
you to stop the water flow to your shower
system without turning off the water to the
rest of the bathroom or home.)
Trim Installation Instructions
1
Remove two round mud guards by turning counter-closewise and discard. Remove the rough-in box and discard.
2
Screw small decorative tube(1) over the diverter valve and slide large decorative tube(2) and
cartridge cover(3) onto the pressure balancing
valve.
1
4 5
Use water to wet the round rubber gaskets on
the cover plate(4) and slide cover plate over(4)
6
two decorative tubes. Gently press cover plate(4)
against the finished wall.
Screw the Gear Cipher Adapter(5) on the diverter
cartridge.
2
3
Install cartridge handle(6) and diverter handle(7). Secure by tightening set screw by using the
supplied Allen Wrench. Cover the hole with the
7
supplied plug.
3
When firmly securing the trim plate onto the wall, apply a thin layer of silicone sealant around its
perimeter to prevent water splashes from entering
the wall.
Make sure not to apply it to the back of the trim
plate, in order to avoid potential issues during
future disassembly.
Cleaning and Maintenace Instructions
1
Remove cartridge handle(7), diverter handle(6) and Gear Cipher Adapter(5).
Remove the trim panel(4).
Remove the decorative ring(1) and decorative
1
4 5
sleeve tube(2).
6
2
3
7
2
Using light force only, turn 2 check stops clockwise to close the check stops with the flat head
screwdriver, until you feel resistance, the check
stops are in the closed position.
Close
Close
3
Remove the retaining nut using an adjustable wrench.
Use two fingers to grasp the stem of the cartridge
and wiggle, then pull out.
Shake cartridge and ensure that a clicking sound
is heard, which means the pressure balancing
spool moves freely and works properly.
You may soak the cartridge in 50-50 vinegar/water
mix to remove any calcium and mineral build-up.
Replace the cartridge if it is damaged.
Shower Head and Shower Arm Instructions
1
SHUT OFF WATER SUPPLIES. Consider the type and the thickness of your
finished wall before placing your stringer back
plate.
Finished wall
Install the threaded adapter (Not supplied) so the
surface of the finished wall is flush with the front
of the threaded adapter.
Flush with the finished wall
Make sure that 1/2″ threaded adapter is installed securely inside the wall.
2
Slide escutcheon over shower arm, and apply Teflon tape onto male threads.
3
Screw the shower arm into threaded adapter. Screw the shower head onto the shower arm and
tighten with an adjustable wrench.
Hand Shower Holder Instructions
1
SHUT OFF WATER SUPPLIES. Please note the wall type and thickness before
positioning the stringer back plate. Attach the 1/2″
NPT nipple (Not supplied) in a manner that allows
1/2″(13mm)
it to extend 1/2″ (13 mm) beyond the finished wall
surface.
1/2″-14 NPT Finished wall
2
1/2″(13mm)
3
Wrap plumber’s tape around the threaded ends of the 1/2″ (13 mm) pipe nipple
(not provided), then proceed to attach the Quick Connect onto the pipe
nipple’s threaded end.
Place the escutcheon over the hand shower holder, then attach the hand shower
holder to the quick connect. Secure it in place using the provided Allen key.
Tub Spout Instructions
1
Finished wall Flush with the finished wall
SHUT OFF WATER SUPPLIES. Consider the type and the thickness of your finished wall before placing your stringer back plate. Install the threaded adapter (Not supplied) so the surface of the finished wall is flush with the front of the threaded adapter. Make sure that 1/2″ threaded adapter is installed securely inside the wall.
2
Slide escutcheon over tub spout, and apply Teflon tape onto male threads.
3
Screw tub spout into the threaded adapter.
Limited Lifetime Warranty
Thank you for choosing our faucets and accessories. We are dedicated to
providing you with exceptional products that are built to last. CASA FIXTURES
is proud to offer a comprehensive limited lifetime warranty on our kitchen and
bathroom faucets and accessories. Here are the details of our warranty policy:
CASA FIXTURES warrants the structure and finish of the faucets and accessories
to be free from defects in material and workmanship under normal usage for as
long as the original purchaser resides in the residence in which the product
was first installed. Additionally, the following warranty periods apply to
specific components:
· Sprayhead Assembly: CASA FIXTURES warrants the sprayhead assembly, including
the engine, aerators, structure, restrictors, backflow preventers, sprayer
hoses, and braided supply line hoses (nylon, silicon, and stainless steel), to
be free from defects in material and workmanship under normal usage for a
period of one (1) year from the date of purchase.
· Cartridge: CASA FIXTURES warrants the faucet’s cartridge to be free from
defects in material and workmanship under normal usage for a period of five
(5) years from the date of purchase.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>