EBYTE NA111-A Serial Ethernet Serial Server
Product Overview
The NA111-A is a serial port server that converts serial port data to Ethernet data. It has multiple Modbus gateway modes and MQTTC/HTTPC IoT gateway modes, making it suitable for various serial port devices/PLCs. The product comes with an RJ45 interface and 3*3.81mm Phoenix terminal for guide rail installation. It adopts industrial design standards to ensure equipment reliability.
PRODUCT Features
- Configurable gateway
- Supports quick access to Alibaba Cloud, Baidu Cloud, OneNET, Huawei Cloud, and standard MQTT servers of version 3.1
- Supports HTTP protocol (GET/POST request)
- Supports virtual serial port
- Supports timeout restart function, time can be customized
- Supports short connection function, short connection interval time customization
- Supports heartbeat package and registration package function
- Supports serial port cache cleaning function
- Supports access to external network and local area network
- Supports hardware reset to factory settings
- Supports online upgrade function
Product Usage Instructions
Preparation for Use
Before using the serial server, you need to prepare network cables, computers, USB-to-serial converters, and other related accessories. Make sure you have the following:
- NA111-A device
- Cable
- Computer
- Plug Wire
- USB to RS485 converter
Device Wiring
Connect the NA111-A to power (AC 85-265v, L (live, red), N (neutral, blue)). Connect the serial port and network port as follows:
- Use the standard 10M/100M self-adaptive RJ45 network port. After correct access, the orange indicator light of the device network port is always on, and the green indicator light is flashing.
- Use the standard RS485 interface (4*3.81mm Phoenix terminal). Connect the device 485-A to the A.
Disclaimer
EBYTE reserves all rights to this document and the information contained
herein. Products, names, logos and designs described herein may in whole or in
part be subject to intellectual property rights. Reproduction, use,
modification, or disclosure to third parties of this document or any part
thereof without the express permission of EBYTE is strictly prohibited. The
information contained herein is provided “as is” and EBYTE assumes no
liability for the use of the information. No warranty, either express or
implied, is given, including but not limited, with respect to the accuracy,
correctness, reliability, and fitness for a particular purpose of the
information. This document may be revised by EBYTE at any time. For the most
recent documents, visit www.ebyte.com.
Note:
The contents of this manual are subject to change due to product version
upgrades or other reasons. Chengdu Ebyte Electronic Technology Co.,Ltd.
reserves the right to make changes to the contents of this manual without
notice or suggestion. This manual serves only as a user guide and Chengdu
Ebyte Electronic Technology Co.,Ltd. endeavours to provide accurate
information in this manual, but Chengdu Billionaire Electronics Co., Ltd. does
not ensure that the contents are completely error-free and that all
statements, information, and suggestions in this manual do not constitute any
express or implied warranty.
Product Overview
Brief Introduction
NA111-A is a serial port server that realizes serial port data ⇌ Ethernet data
conversion; it has multiple Modbus gateway modes and MQTTC/HTTPC IoT gateway
modes, which can meet the networking functions of various serial port
devices/PLCs; Industrial design standards are adopted to ensure the
reliability of equipment; The product comes with RJ45 interface and 3*3.81mm
Phoenix terminal, guide rail installation.
- RJ45 adaptive 10/100M Ethernet interface;
- Support multiple working modes (TCP Server, TCP Client, UDP Server, UDP Client, HTTPC, MQTTC);
- Support three configuration methods: configuration tool, web page and AT command;
- Server mode supports multiple socket connections;
- Support multiple baud rates;
- Support DHCP function;
- Support DNS (domain name resolution), and custom domain name resolution server;
- Support multiple Modbus gateways (simple protocol conversion, multi-host mode, storage gateway, configurable gateway, etc.);
- Supports quick access to Alibaba Cloud, Baidu Cloud, OneNET, Huawei Cloud, and standard MQTT servers of version 3.1;
- Support HTTP protocol (GET/POST request)
- Support virtual serial port;
- Support timeout restart function, time can be customized;
- Support short connection function, short connection interval time customization;
- Support heartbeat package and registration package function;
- Support serial port cache cleaning function;
- Support access to external network and local area network;
- Support hardware reset to factory settings;
- Support online upgrade function.
Quick Start
Preparation for use
Before using the serial server (hereinafter referred to as “device”), you need
to prepare network cables, computers, USB-to-serial converters and other
related accessories. details as follows:
Device wiring
NA111-A power wiring (AC 85-265v, L (live, red), N (neutral, blue)): Serial
port and network port and wiring:
- The standard 10M/100M self-adaptive RJ45 network port is adopted. After correct access, the orange indicator light of the device network port is always on, and the green indicator light is flashing;
- The standard RS485 interface (4*3.81mm Phoenix terminal) is used, the device 485-A is connected to the A
of the USB to RS485 converter, and the device 485-B is connected to the B of the USB to RS485 converter (please use the standard RS485 twisted pair for long distances) cable, otherwise it may not be able to communicate normally due to excessive environmental interference);
Software Settings
Network test environment
Avoid server search failures and inability to open web page configuration and
other related problems in the actual application process. Check the computer
settings first.
- Turn off the firewall and anti-virus software of the computer;
- Configure the network card connected to the device;
- In this case, the PC is directly connected to the computer, and the static IP of the computer needs to be configured. The static IP of the computer, refer to the PC direct connection configuration) or the router needs to ensure that the device and the PC are on the same network end (for example 192.168.3.xxx);
- Here, configure the static IP of the PC as 192.168.3.3 (the factory default destination IP of the serial port server), configure the subnet mask as 255.255.255.0, and configure the default gateway as 192.168.3.1;
Default parameters
Item | default parameters |
---|---|
IP Address | 192.168.3.7 |
Default local port | 8887 |
subnet mask | 255.255.255.0 |
default gateway | 192.168.3.1 |
Default working mode | TCP Server |
Default destination IP | 192.168.3.3 |
Default destination port | 8888 |
Serial port baud rate | 115200 |
Serial port parameters | None / 8 / 1 |
Data transmission test
After the above operation steps, follow the factory default parameters of the
device and perform the following operations to realize the transparent
transmission test of data. The operation steps are as follows:
- Open the test TCP/IP debugging assistant software.
- Select the TCP client mode (TCP Client) in the “Network Setting Area”, corresponding to the remote host address (the default local IP of the device: 192.168.3.7). The remote host port corresponds to the factory port 8887 of the device, click Connect.
- Wait for the computer to connect to the serial server. After the connection is completed, the LINK light of the serial server is always on.
- Open the serial port assistant, select the corresponding serial port, set the baud rate to 115200, set other serial port parameters to None/8/1, and click “Open Serial Port”.
Data transmission test, the serial port assistant (serial port side) sends the test data, and the network debugging assistant (network side) receives the test data. The network debugging assistant (network side) sends test data, and the serial port assistant (serial port) receives test data. Realize duplex communication (that is, two-way data sending and receiving from local to network).
Product Overview
Technical parameters
Item | Instruction |
---|---|
Operating Voltage | AC 85~265V |
Interface | Serial port (RS485, 3*3.81mm phoenix terminal) |
Ethernet port (RJ45)
Work Mode| TCP Server、TCP Client、UDP Server、UDP Client、HTTP Client、
MQTT Client(default TCP Server)
Socket connection| Support 6-way client connection (TCP server mode)
Network protocol| IPv4、TCP/UDP、HTTP、MQTT
How to get IP| DHCP、Static IP (default static IP)
DNS| Support
DNS server| Customizable (default 114.114.114.114)
Configuration method| Web pages, configuration tools, AT commands
IP address| Customizable (default 192.168.3.7)
local port| Customizable (default 8887)
subnet mask| Customizable (default 255.255.255.0)
gateway| Customizable (default 192.168.3.1)
target IP| Customizable (default 192.168.3.3)
destination port| Customizable (default 8888)
Serial port cache| 1024Byte
Packaging mechanism| 512 Byte
Serial port baud rate| 1200 ~ 230400 bps(default 115200)
data bits| 5、6、7、8(default 8)
stop bit| 1、2(default 1)
Check Digit| None、Odd、Even、Mark、Space(default None)
Product Size| 92 mm 66mm 30mm (lengthwidthheight)
product weight| 93g ± 5g
Working temperature
and humidity
| -40 ~ +85℃、5% ~ 95%RH(no condensation)
Storage temperature
and humidity
| -40 ~ +105℃、5% ~ 95%RH(no condensation)
Interface and Indicator Description
No. | Name | Function | Instruction |
---|---|---|---|
1 | Restore | Restore | Press and hold for 5 seconds to restore factory Settings |
2 | RJ45 | Ethernet | Ethernet interface |
3 | G | Signal ground | RS458 signal ground, The first pin of the 3 x 3.81mm |
terminal
4| A| RS458 signal A| RS458 signal A connects to RS485 signal A of the
terminal
device, Second pin of the 3 x 3.81mm terminal
5| B| RS458 signal B| RS458 signal B connects to RS485 signal B of the terminal
device, The third pin of the 3 x 3.81mm terminal
6| PWR-LED| Power LED| The power input indicator is steady on
7| TXD-LED| Serial send light| Data sent: Light on.
No data sent: Lights off.
8| RXD-LED| Serial reception
indicator
| Data sent: Light on.
No data sent: Lights off.
9
|
M0-LED
|
Link light
| TCP mode: network connection, light on. The network is down and the lights are off.
UDP mode: The light is always on.
10| M1-LED| STATE indicator| The network cable is connected and the light is always on.
The network cable is disconnected and the light goes out.
11
|
PWR
|
power interface
| 2*5.08mm power input interface, the left side is positive, the right side is negative;
Power input range: DC8-28V.
[Note] When the network cable is not connected, PWR, TXD,RXD, and M0 all light up, and the device is in the standby state.
Dimensions
Installation method
The equipment is mounted by rail.
Functional Introduction
Serial port parameters
The basic parameters of the serial port include baud rate, data bits, stop
bits, and parity bits. Baud rate: serial communication rate, configurable
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 230400bps.
Data Bits: The length of the data bits, the range is 5, 6, 7, 8. Stop
bit: range 1, 2 can be set.
Check digit: The check digit of data communication, supports five check
modes: None, Odd, Even, Mark, Space.
Flow Control: Does not support.
Introduction to basic functions
Web page configuration
The device has a built-in web server, which is convenient for users to set and
query parameters through web pages.
The port of the web server can be customized (2-65535), default: 80 Operation
method (Microsoft Edge version 94.0.992.50 is an example, it is recommended to
use Google kernel browser, IE kernel browser is not supported):
- Step 1 : Open the browser, enter the IP address of the device in the address bar, for example 192.168.3.7 (the IP address and the computer need to keep the same network segment), if you forget the IP of the machine, you can query it through AT commands and configuration software
- Step 2: The webpage pops up the main interface, and you can query and set relevant parameters;
- Step 3: Click Submit to save the configuration parameters after entering the correct key. The factory default key is: 123456;
- Step 4: The progress bar indicates the configuration progress. Do not refresh the web page again after the configuration is completed (refresh the web page to enter the configuration mode again, you can restart the device or submit it again to enter the communication mode);
It can also be opened through the Open Web Configuration button of the
configuration software.
[Note] If the port number is modified, the port number should be added to
the address input field. For example, if you modify the web page access port
to 8080, you need to enter 192.168.3.7:8080 in the address bar to connect to
the web page configuration.
Subnet mask/IP address
The IP address is the identification of the module in the local area network
and is unique in the local area network. Therefore, it cannot be duplicated
with other devices on the same local area network. There are two ways to
obtain the IP address of the module, static IP and DHCP.
- Static IP: Static IP needs to be set manually by the user. In the process of setting, pay attention to writing IP, subnet mask and gateway at the same time. Static IP is suitable for scenarios where IP and device statistics are required and one-to-one correspondence is required.
- Advantages: Access to devices that cannot be assigned IP addresses can be searched through the broadcast mode of the entire network segment, which is convenient for unified management;
- Disadvantages: Different network segments in different LANs, resulting in normal TCP/UDP communication.(2) Dynamic DHCP: The main function of DHCP is to dynamically obtain the IP address, gateway address,
DNS server address and other information from the gateway host, thereby eliminating the tedious steps of setting the IP address. It is suitable for scenarios where there is no requirement for IP, and there is no mandatory one- to-one correspondence between IP and modules. Advantages: devices with DHCP Server such as access routers can communicate directly, reducing the trouble of setting IP address gateway and subnet mask. Disadvantage: Connecting to a network without DHCP Server, such as direct connection with a computer, the module will not work properly. The subnet mask is mainly used to determine the network number and host number of the IP address, to indicate the number of subnets, and to determine whether the module is in the subnet. The subnet mask must be set. Our commonly used class C subnet mask: 255.255.255.0, the network number is the first 24 bits, the host number is the last 8 bits, the number of subnets is 255, and the module IP is in the range of 255 within this subnet, the module IP is considered to be in this subnet. Gateway refers to the network number of the network where the current IP address of the module is located. If a device such as a router is connected to the external network, the gateway is the router
Domain Name Resolution (DNS)
Domain name resolution translates domain names into network-recognized IP
addresses through Domain Name Resolution (DNS) servers. The domain name
resolution (DNS) server address of the serial port server supports user
definition, and can realize domain name resolution through a custom domain
name resolution server in the event of an abnormal domain name server. The
device will report the resolution to the custom domain name resolution (DNS)
server during domain name resolution. Request, return the device connection
parameters (usually the IP address) after the parsing is completed.
In DHCP mode, the domain name resolution (DNS) server address is automatically
obtained (synchronized with the router’s domain name resolution address) and
cannot be modified. In static IP mode, the factory default address of the
Domain Name Resolution (DNS) server is 114.114.114.114.
Restore factory settings
Press and hold the Reload pin of the device until the LED indicator lights
up to release the key.
Socket function
TCP server mode
TCP Server is the TCP server. In TCP Server mode, the device listens to the
local port, accepts the client’s connection request and establishes a
connection for data communication. When the Modbus gateway function is turned
off, the device sends the data received by the serial port to all client
devices that establish connections with the device, and supports connecting up
to 6 clients. After the Modbus gateway function is enabled, the non-Modbus
data will be cleared and not forwarded. Typically used for communication with
TCP clients within a local area network.
TCP Client Mode
TCP Client is the TCP client. When the device is working, it will actively
initiate a connection request to the server and establish a connection to
realize the interaction between serial port data and server data. To use the
client, you need to configure the target IP address/domain name and target
port accurately.
UDP Server Mode
UDP Server means that the device does not verify the IP address of the data
source when communicating with the UDP protocol. After receiving a UDP data
packet, it saves the source IP address and source port of the data packet, and
sets it as the destination IP and port, so The data sent by the device only
sends data packets to the source IP address and port where the device received
data last time. This mode is usually used in scenarios where multiple network
devices communicate with this device, and the frequency is high, and the TCP
Server cannot meet the conditions. Using UDP Server requires the remote UDP
device to send data first, otherwise the data cannot be sent normally.
[Note] In UDP mode, the data sent by the network to the device should be
less than 512Bit per packet, otherwise, it will cause data loss
UDP Client Mode
UDP Client is a connectionless transmission protocol that provides
transaction-oriented simple and unreliable information transmission services.
There is no connection establishment and disconnection, and data can be sent
to the other party only by configuring the destination IP and destination
port. It is usually used in data transmission scenarios where there is no
requirement for the packet loss rate, the data packets are small and the
transmission frequency is fast, and the data is to be transmitted to the
specified IP. In UDP Client mode, the device will only communicate with the
configured (target IP and target port) remote UDP devices.
In this mode, the target address is set to 255.255.255.255, and the sent data
will be broadcast on the entire network segment, but the transceiver device
needs to ensure that the ports are consistent, and the device can also receive
broadcast data.
HTTP Client Mode
This mode can realize the function of HTTP grouping. It provides two modes:
GET and POST. Customers can configure URL, Header and other parameters by
themselves, and the device (serial port server) will send packets to realize
fast communication between the serial port device and the HTTP server. In HTTP
client mode, it is recommended to use random ports and enable short
connections to save HTTP server resources.
Configure the local network parameters and the HTTP server address and port(You are advised to enable DHCP and random ports), As shown in the figure below(Above is the upper computer, below is the web page):
MQTT Client mode
The serial port server supports quick access to standard MQTT3.1.1 protocol
servers (OneNET, Baidu Cloud, Huawei Cloud, user-built and other server types)
and Alibaba Cloud servers, supports service quality level configuration (QoS
0, QoS 1), and supports super long text Configuration, convenient and better
access to network service operators (server address, three elements,
subscription and publishing addresses support up to 128 characters of
configuration).
Alibaba Cloud
Alibaba Cloud Supports the use of Alibaba Cloud’s “Three Elements” to directly
connect to the server to obtain the “Three Elements” required to connect to
Alibaba Cloud, as shown in the figure(The following parameters are only
examples):
Select the corresponding product, go to “Custom Topic” under the Topic class list (for details, please refer to the Alibaba Cloud documentation), click “Define Topic Class”, set the name to 1234, and grant publish and subscribe permissions (for data return pass). Configure the device connection parameters, as shown in the following figure:
- “ProductKey”: “a1GlhuTU1yN”,
- “DeviceName”: “DEV04”,
- “DeviceSecret”: “xxxxxxxxxxxxxxxxxxxxxxxxxxx”
Alibaba Cloud server address: ProductKey.iot-as-mqtt.cn- shanghai.aliyuncs.com:1883 Topic for subscription and publication: /a1GlhuTU1yN/DEV04/user/1234
Advanced Features
Random native port
TCP client, UDP client, HTTP client, MQTT client can configure the local port
to 0 (use random local port), and server mode cannot use random port,
otherwise the client cannot establish a connection correctly. Using a random
port connection can quickly re-establish the connection when the device
disconnects the server unexpectedly, preventing the server from rejecting the
connection due to four waves of incompleteness. It is recommended to use a
random port in client mode .
The device will automatically enable random ports when configuring the TCP
client, HTTP client, and MQTT client modes.
Heartbeat Packet Function
In client mode, users can choose to send heartbeat packets and set the time of
heartbeat packets by themselves. The heartbeat packet can be selected in two
modes: network heartbeat packet and serial port heartbeat packet. It supports
hexadecimal and ASCII transmission. This heartbeat packet is not MQTT
heartbeat and needs to be turned off in MQTT client mode. MQTT heartbeat only
needs to configure KeepAlive in “MQTT function settings” Time, it is
recommended not to configure less than 60s, for example, 120s is recommended
in the Alibaba Cloud manual.Heartbeat packet sending mode:
- The default is to turn off the heartbeat packet mode.
- Serial port mode -> The device sends heartbeat content to the serial bus according to the set heartbeat interval.
- Network port mode -> The device sends heartbeat content to the network port bus according to the set heartbeat interval. Customize heartbeat packet content (maximum support 40 bytes (ASCII) data, 20 bytes (HEX) data) Customize the interval for sending heartbeat packets. When it is set to 0, the heartbeat packet function is turned off. If the setting value is greater than zero, the heartbeat packet function is turned on. When it is turned on, the range can be set: (1-65536) seconds.
Registration package function
In the client mode, the user can choose to send the registration package, and
set the registration package time by definition.The registration package
supports the following modes:
- The MAC address (OLMAC) is sent when the network establishes a connection with the device
- The data of the custom registration package sent when the network establishes a connection with thedevice (OLCSTM)
- After the network and the device are connected, each packet of data sent by the device to the network is preceded by a MAC address (EMBMAC)
- After the network and the device are connected, each packet of data sent by the device to the network is prepended with custom registration packet data (EMBCSTM)Custom registration package content (maximum support 40 bytes (ASCII) data, 20 bytes (HEX) data)
Short connection function
In client mode, short network connection is supported (this function is
disabled by default). TCP short connection is mainly used to save server
resource overhead, and is generally used in multi-point (multi-client)-to-
point (server) scenarios. In client mode, short network connection is
supported (this function is disabled by default). TCP short connection is
mainly used to save server resource overhead, and is generally used in multi-
point (multi-client)-to-point (server) scenarios. When the short link hold
time is set to 0, the short link function is turned off. When the setting
range is (2-255) seconds, the short connection function is enabled, and the
default hold time is 0 seconds (disabled).
Timeout restart function
Supports the timeout restart function (default: 300 seconds), which is mainly
used to ensure the long-term stable operation of the device. If data is not
sent and received within the set timeout restart time, the device will restart
to avoid the impact of abnormal conditions on communication. The parameter
range of timeout restart time is (60-65535) seconds. If it is set to 0, it
means shutdown timeout restart. The default is 300 seconds.
Cache cleaning function
The device is in the client mode. When the TCP connection is not established,
the data received by the serial port will be placed in the buffer area. The
serial port receiving buffer is 1024 bytes, and the data larger than 1024
bytes will cover the earliest received data. After the network connection is
successful, you can Select to clear the serial port cache or send the cache
through the network through configuration.Enable: The device does not save the
data received by the serial port before the connection is established.
Disabled: After the connection is established, the network will receive the
serial buffered data.
Network disconnection and reconnection
In client mode, after the device is disconnected from the network, it will try
to actively connect to the server at the specified time. If the request times
out and the set number of reconnections has not been successfully reconnected,
the device will restart to prevent the device from disconnecting from the
network. Unable to restore connection. Disconnection and reconnection time:
The time interval between each attempt of the device to re-establish the
network. Number of reconnections: The number of times the device tries to re-
establish the network, and the cumulative number of requests reaches the
preset value. If the connection is not successful, the device will
automatically restart. The actual restart time is the network disconnection
reconnection period multiplied by the number of reconnections. It is
recommended to use the factory default parameters without special
requirements.
Remote upgrade
In order to facilitate later maintenance and upgrade functions and to replace
different firmware, the serial server (NA11x series, NB114, NS1, NT1, etc.)
supports online upgrade, and users can upgrade or replace the current firmware
through the upgrade firmware provided by our company through the host
computer.
Network upgrade firmware operation steps:
- Step 1: Open the host computer, open the device upgrade assistant in the menu bar, and select the required firmware (The official website only provides the latest firmware, please refer to “Firmware Instructions” for details);
- Step 2: Click to search for devices, and click to stop searching after finding the device;
- Step 3: Select the corresponding device that needs to be upgraded;
- Step 4: Click to start the upgrade, the device indicator flashes, and wait for the upgrade to complete.
[Note] When the device is just powered on, click “Search Device” in the upgrade assistant, the device will enter the firmware burning state, and it will return to normal mode after power off and restart.
Modbus Gateway
Modbus RTU and Modbus TCP protocol conversion
Enable(Check): Convert Modbus RTU protocol to Modbus TCP protocol.
Disabled: Do not perform protocol conversion but verify Modbus data, discard
non-Modbus data (RTU/TCP) and not transmit.
Simple Protocol Conversion Mode
Convert Modbus RTU data to Modbus TCP data, or convert Modbus TCP data to
Modbus RTU data, to realize the mutual conversion of Ethernet Modbus data and
serial port Modbus data. Simple protocol conversion can work in any mode (TCP
client, TCP server, UDP client, UDP server etc.), no matter what mode it is
working in, there can only be one Modbus master station. Simple protocol
conversion configuration (TCP server mode as an example, the upper computer on
the left, web page on the right).
Multi-host mode
There is only one Modbus master station for relatively simple protocol
conversion, while the multi-master mode can handle up to 6 Modbus TCP masters.
One request is processed at a time, while the multi-host mode will be
sequenced according to the TCP request, and other links will wait) to solve
the bus conflict problem (currently only 6 host connections are supported),
only supports working in TCP server mode, slave machine Only in the serial
port, otherwise, it will not work properly.It is recommended to configure
“Simple Protocol Conversion” when no multi-channel host is used. Multi-host
mode configuration (upper computer, web page below) :
Storage Gateway
The storage gateway not only arbitrates the bus data but also stores the
repeated read commands. When different hosts request the same data, the
gateway does not need to query the register status of the RTU device multiple
times, but directly returns the data cached in the storage area. To a certain
extent, the multi-host request processing capability of the gateway is
improved, and the time consumed by the entire request process is also
shortened. Users can customize the storage area command polling interval and
command storage time according to their needs. As the optimization of multi-
host request performance, the storage gateway can only work in the TCP server
mode, which improves the response speed of the network side.
Features:
- The gateway has a 5K cache for storing instructions and returning results (reading 10 holding registers an example, it can store 189 instructions and return results);
- The RTU response time-out automatically clears the cache to ensure the real-time and authenticity of the
- The polling interval can be customized, 0-65535ms;
- The gateway will poll the RTU device according to the storage time of the instruction used for configuration. If the MODBUS host does not query the instruction again during the storage time, the gateway will automatically delete the storage instruction to release the cache;
- The first command and control command (05, 06, 0F, 10 function codes) will directly access the RTU device;
- Only 01, 02, 03, 04 Modbus function code query result storage is supported; Storage gateway configuration (upper computer, web page) :
Configurable Gateway
The gateway automatically polls the RTU device registers according to the pre-
configured MODBUS commands (only supports the configuration of the MODBUS read
command), and the commands in the non-storage table will directly operate the
RTU device. Frequently read commands can be stored in the gateway in advance,
which can shorten the response time (query configured commands). Due to the
above features, the serial port side of the configurable gateway can only be
connected to Modbus slaves.![4.5.5 Configurable Gateway
The gateway automatically polls the RTU device registers according to the pre- configured MODBUS commands (only supports the configuration of the MODBUS read command), and the commands in the non-storage table will directly operate the RTU device. Frequently read commands can be stored in the gateway in advance, which can shorten the response time (query configured commands). Due to the above features, the serial port side of the configurable gateway can only be connected to Modbus slaves.](https://manuals.plus/wp- content/uploads/2023/05/EBYTE-NA111-A-Serial-Ethernet-Serial-Server-FIG-32.jpg )
Configurable gateway configuration (Left picture software right picture web page) :
Automatic upload
In client mode (TCP client, UDP client etc.), the gateway will automatically
poll the instructions in the stored instruction table and upload it to the
server, and the feedback format (Modbus RTU format or Modbus TCP format) can
be selected according to the requirements. ) and the command polling interval
(0-65535ms).
For instruction pre-storage, refer to “Configurable Gateway – Instruction
Storage Instructions”, and automatically upload the upper computer/web page
configuration:
TCP client demo (Modbus RTU format on the left and Modbus TCP format on the right):
Configuration Mode
Web Settings
You can customize the relevant parameters through the Web setting method. Open
the browser, enter the device IP in the address bar (default: 192.168.3.7),
enter the page, you can query and set parameters, and finally click the
“Submit” menu to wait for the page to return to the successful prompt, and it
will take effect.
Note: Do not enter the web page configuration during normal use, which may
cause data loss. If you enter the web page configuration, you need to restart
to enter the communication mode.
Web page configuration initialization password: 123456, can be customized
configuration, only supports 6-bit uppercase and lowercase letters and
numerical configuration.
The webpage configuration requires browsers with newer kernels to work
properly, such as Microsoft Edge (96.0.1054.62), Google chrome
(96.0.4664.110), Firefox (95.0.2), etc.
[Note] IE, 360 compatibility mode, QQ browser compatibility mode and
other browsers using IE core are not supported to use web page configuration.
5.2 Configuration tool software settings
Open the configuration tool software, search for devices, double-click the
identified device, and the parameter query configuration interface will pop
up. You can customize and modify relevant parameters according to your needs,
then save the configuration, restart the device, and complete the parameter
modification.
Note】: Do not use multiple host computers in the same local area network
environment. Multi-network card industrial computers need to temporarily
disable and do not use network cards, otherwise the host computer will not be
able to search for devices normally (the same device is displayed multiple
times, no device can be found, etc.)
The host computer shields the wireless network card, so the network cable must
be connected to use the host computer, and the wireless network card can be
configured through the web page.
AT command configuration
The query and modification of relevant parameters of the device can be
completed through AT command configuration. For specific AT commands, please
refer to “NA11x&NT&NS-AT Command Set”.
Version | Date | Description | Issued by |
---|---|---|---|
1.0 | 2021-06-28 | Initial version | LC |
1.1 | 2022-09-13 | Content revision | LZX |
1.2 | 2022-02-12 | Adapt to “9013-2-xx” firmware | LC |
About us
- Technical support: support@cdebyte.com.
- Documents and RF Setting download link: www.ebyte.com.
- Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com —————————————————————————-
- Phone: +86 028-61399028
- Web: www.ebyte.com.
- Address: B5 Mould Park, 199# Xiqu Ave, High-tech District, Sichuan, China
- Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.