CLF LIGHTING Haze II Built-In Flightcase Touring Hazer User Manual

June 4, 2024
CLF LIGHTING

CLF LIGHTING Haze II Built-In Flightcase Touring Hazer User Manual

CLF LIGHTING Haze II Built-In Flightcase Touring Hazer User
Manual

DIMENSIONS

ALL DIMENSIONS ARE IN MILLIMETERS

CLF LIGHTING Haze II Built-In Flightcase Touring Hazer User Manual -
Dimensions

MACHINE OVERVIEW

CLF LIGHTING Haze II Built-In Flightcase Touring Hazer User Manual - Product
Overview

  1. LCD Display
  2. 3-pin OMX socket
  3. 5-pin OMX socket
  4. Breaker
  5. Power cord (Powercon from 2022)
  6. Fluid container
  7. Fluid container handle
  8. Fluid container fixation
  9. Smoke output

SAFETY INSTRUCTION

⚠ WARNING!
Read the safety precautions in this section before installing, powering, operating or servicing this product

CLF LIGHTING Haze II Built-In Flightcase Touring Hazer User Manual - Safety
Instruction CLF LIGHTING Haze II Built-In Flightcase Touring Hazer
User Manual - Safety Instruction

RC POWER

POWER VOLTAGE
Check that the voltage range specified on the machine serial number label matches the local AC mains power voltage before applying power to the fixture. The machine accepts AC mains power at 100-240 V nominal. 50/60 Hz. Do not apply AC mains power to the machine at any other voltage than specified.

POWER CABLES
Power input and throughput cables must be rated 20 A minimum, have three conductors 1.5 mm2 (16 AWG)
minimum conductor size and an outer cable diameter of 5 – 15 mm. Cables must be hard usage type (SJT or equivalent) and heat- resistant to 90ºc minimum. In the EU the cable must be HAR approved or equivalent. If you install a power plug on the power cable, install a grounding-type (earthed) plug that is rated 20 A minimum. Follow the plug manufacturer’s instructions. Table 1 shows standard wire color-coding schemes and some possible pin identification schemes; if pins are not clearly identified, or if you have any doubts

CLF LIGHTING Haze II Built-In Flightcase Touring Hazer User Manual - Wire
color coding and power connections

A DMX 512 data link is required in order to control a machine via DMX. The machine has 3 & 5-pin XLR connectors for DMX data input and output. The pin- out on all connectors is pin 1 = shield, pin 2 = cold (-), and pin 3 = hot(+) Pins 4 and 5 in the 5-pin XLR connectors are not used.

TIPS FOR RELIABLE DATR TRANSMISSION

To connect the machine to data:

  1. Connect the DMX data output from the controller to the closest machines male 3 & 5-pin XLR DMX input connector.
  2. Connect the DMX output of the machine closest to the controller to the DMX input of the next machine and continue connecting machines output to input.

PHYSICAL INSTALLATION

Warning! The machine must be either fastened to a flat surface such as a stage or wall, or clamped to a truss or similar structure in any orientation using a rigging clamp.
Warning! At all times machine can cause injury or damage it if falls, attach an approved safety cable to one of the safety cable attachment points on the base (see “machine overview” on page 4).

OPERATING INSTRUCTIONS

  1. After checking that all the parts are intact and complete, position the machine on a flat surface.
  2. Only use designated CLF Lighting haze liquid. Machine can be harmed when using other fluids and warranty is expired
  3. Connecting the power cord. Before power on, make sure it is connected with the rated voltage.
  4. Tum on the machine, it will immediately start heating up, the digital display will show “WARMING UP”.

MENU INSTRUCTION

  1. MENU button: When it shows “HEAT”, press “menu” button to enter the page “ADDR”
  2. UP button: Increase the relevant value of each page
  3. DOWN button: Decrease the relevant value of each pag
  4. ENTER button: Enter or exit each page

MENU: Scroll through setting menu;
UP: Increase, multiplex “TIMER” button;
DOWN: Decrease, multiplex “VOLUME” button;
ENTER: In/Out, multiplex “stop” button;

Press” MENU” button to switch different pages, 9 pages in total:

  1. Ready To Fog: The machine is ready to work
  2. Interval Set: To set the interval of timer mode , adjustable from 5-200s
  3. Duration Set: To set the duration of timer mode , adjustable from 5-200s
  4. Timer out: Set the haze fog output from 1 – 100% under Timer mode
  5. Volume out: Set the haze fog output from 1 – 100% under Volume mode
  6. Fan speed: Set the fan speed from 1 – 100%
  7. DMX512 Address: The DMX address can be set up from 1 to 512
  8. Direct timer: Direct timer on / off after power on
  9. Language: Select the language saved by “Enter”

Under any setting pages, press STOP to exit or return to the page one.

When the unit is working, press STOP to stop running and return to the page one. After enter into different setting pages, press UP and DOWN to change the value. When it is in the page one, press TIMER button to enter into timer mode.

DMX CHANNELS

CLF LIGHTING Haze II Built-In Flightcase Touring Hazer User Manual - DMX
Channels

MAINTENANCE

Fluid injection trouble:
Refers to the fog fluid atomizing in the heater pipe of the machine is not good, heater temperature cannot be timely and effective transmit to the fog fluid, fog fluid cannot all atomization and lead to fluid injection.

  1. Using the low quality or counterfeit fog fluid, low quality fog fluid have more impurities, easy to adhere to the pipe wall and hindered temperature transmission result in incomplete atomization caused fluid injection.
  2. Using an incorrect fog fluid. Different fog fluid have different required atomization temperature. If you use the wrong fog fluid result in oil cannot fully atomization caused fluid injection.(fig 1)

Heater blocking trouble:
Poor atomization fluid injection is the easy signs of heater block. Using no CLF quality fog fluid or not timely maintenance dealing the fog machine for a long lime. Inevitable will appear the terminal symptom of heater blocking.

  1. heater blocked is because used inferior fog fluid or not maintenance for a long time. Have nothing to do with the quality of machine.
    Like a car with poor quality gasoline produce poor fluid circuit failure or long-time no maintenance the car will inevitably appear bigger problems. (fig

Solutions to these problems:
Fog machine heating pipes used for a long time and then the pipe wall will easily produce sediments (The more inferior fog fluid the more impurities thus lead to fluid injection or blocked). All fog machines need regular maintenance (fog machine maintenance cycle for 1 to 2 months/time).

Specific maintenance method: after heating the 35% white vinegar plus 65% distilled water and then spray 1 Oto 15 limes

Conclusion:
As long as the fog machine with fluid injection or heater blocking after using a period of time. It was caused by fog fluid quality or lack of maintenance, has nothing to do with the quality of the machine. Please use the CLF original high quality fog fluid and timely maintain ii, then ii can be used for a long time

CLF LIGHTING Haze II Built-In Flightcase Touring Hazer User Manual - Fig
1,2

⚠ Fluid restrictions:
Only use CLF or JEM hazer fluid. Any other fluid will damage the machine and warranty is not valid anymore. Always check if the fluid is still dear looking. Never use perfume or any other chemical additions to the hazer.

EXPLODED VIEW

CLF LIGHTING Haze II Built-In Flightcase Touring Hazer User Manual -
Exploded View

  1. Empty flight case CLF-70-035
  2. Top cover CLF-70-036
  3. Air pump support CLF-70-037
  4. Main PCB plate CLF-70-038
  5. Main PCB CLF-70-039
  6. Aluminium heat sink CLF-70-040
  7. Fluid container CLF-70-041
  8. LCD cover CLF-70-042
  9. Display PCB CLF-70-043
  10. Fluid cap CLF-70-044
  11. LCD display CLF-70-015
  12. 3-pin OMX PCB (male/female) CLF-70-046
  13. 5-pin OMX PCB (male/female) CLF-70-047
  14. Front plate CLF-70-048
  15. Copper cap fluid line CLF-70-049
  16. Copper connector fluid line CLF-70-050
  17. Fuse CLF-70-051
  18. Position part air direction CLF-70-052
  19. Air director CLF-70-053
  20. Pump mounting bracket CLF-70-054
  21. Position part air direction inside CLF-70-055
  22. Nozzle CLF-70-056
  23. Filter air direction CLF-70-057
  24. Thermostat CLF-70-058
  25. Heat filter CLF-70-059
  26. Fast heater CLF-70-060
  27. Pump support plate CLF-70-061
  28. Fan CLF-70-062
  29. Air pump CLF-70-063
  30. Fluid pump CLF-70-064
  31. Copper connector fluid pump CLF-70-065
  32. Copper cap fluid pump CLF-70-066
  33. Connection cable CLF-70-067
  34. Cable gland CLF-70-068

SPECIFICATIONS

CLF LIGHTING Haze II Built-In Flightcase Touring Hazer User Manual -
Specifications

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals