Safety Instructions

  • Don’t adjust or alter the unit in any way.
  • The use of unauthorized parts will void your warranty. Contact your approved distributor for assistance.
  • Always unplug the unit prior to removing the cover.
  • Inspect the power cord prior to use and do not use if it is damaged
  • The unit should only be used with a 115V/60Hz circuit protected by a GFCI outlet.

Identification

Prior to installation of the unit, write down the serial number and date of purchase. You will need this information if you nee das si stance in the future. The data label on the side of your unit has the necessary information.

  • Model Number:
  • Hurricane LGR85
  • Serial Number:
  • Date of Purchase:

For additional questions concerning your dehumidifier:

Electrical Supply

  • Power Supply: 115V, 60 Hz AC, Single Phase
  • Outlet Requirement: 3-Prong, CPC’
  • Cicuit Protector: 15 Amp

WARNING:
Using a 240V outlet may cause serious injury from electric shock. To reduce risk of injury:

  1. Always disconnect machine from electrical power before servicing,
  2. Only plug unit into a gounded electrical cicuit.
  3. Do not use an extension cord. 4. Do not use a plug adapter.

How the Hurricane LGR85 Works

The Hurricane LGR85 dehumidifier utilizes its integral humidistat to monitor the conditioned space. Once conditions are outside the desired setpoint, the compresser energizes and air is drawn across an evaporator coil. The evaporator coil is cooler than the dew point of the air so the water vapor will turn into liquid condensation. The air is then reheated through the condenser coil and distributed back into the room

Guidelines

Operation Notes

  • Always make sure that the unit is operated, transported, and stored on a stable surface.
  • For maximum efficiency, operate the unit with all windows and doors closed.
  • Do not place the unit anywhere that may block the inlet or outlet airflow. Drain Hose Notes
  • The dehumidifier is equipped with an external drain line connection, making it easy to plug in.
  • The drain line can be directed outside or into any sink, drain, etc.
  • For more effective draining, uncoil the entire hose before using.
  • Never place the end of the hose higher than 15 feet.
  • Always ensure that the drain hose is not blocked prior to use.

Transportation Notes

  • Always secure the dehumidifier during transportation.
  • If the unit is transported vertically, return it to a normal horizontal position, and let sit for 30 minutes prior to use.

Parts Diagram

Control Panel Guide

Power Button
gm The Power Button is used to turn the dehumidifier on and off.You can also press this button whileon a sub-menu if you wish to retum to the main screen.
Set Button
The Set Button is used to confirm your selected setting, as well as set the humidity level. Each time you press the button, the humidity level will increase 5% (between 25% and 80%). The default humidity level is 50%.
Manual Drain Button
The Manual Drain Button is used before moving or storing the machine. Press the Manual Drain Button to remove water from the integral pump reservoir.

Menu Button
The Menu Button is used to cycle through the different interfaces of the display screen. When cycling through the display, you’ll be able to access nine different sub-menus (Job Hours, Life Hours, Inlet/Outlet Temperatures, Humidistat Mode, Humidity Setpoint, Temperature Measurement, Language, Coil Temperature, Compressor Current).

Using the Display- Main Screen

Power On and Off
To power on the machine, press the power button once. The display will show:

  • To power off the machine, press the power button while on the main display screen. The display will show:

Setting Up the Unit

  • Once the machine has powered on, you will see the following display:

a. UNIT ON- means the unit is powered on.
b. 00.0HRS- describes any time the machine is running from power on to power off. It includes defrosting time, but does not include the standby time once the set point is reached. The working time can be reset using the sub-menu. If it is never reset, the time will accumulate with a maximum time of 99.9 hours. Once the maximum is reached, it will reset to zero.
c. INLET 00°C 00%” desrcibes the temperature and humidity of air inlet. You can switch the temperature measurement (°F/°C) in the sub-menu.
d. When operating in the sub-menu, press the power key to return to the main menu.

Defrosting Screen

  • When the unit enters defrosting mode, it will show “Defrost 000”. This is the countdown until defrosting is finished. After defrost is completed, it will return to the main interface.

NOTE: If you are in a submenu, you will not see the countdown until you return to the main interface.

Maintenance Instructions

Before Use

  • Check the power cord for signs of damage such as fraying. Replace the cord before use if there is any damage.
  • Check the filter for signs of dirt or obstructions. Clean or replace the filter as necessary.
  • Check the coils for signs of buildup. Clean if needed.
    Cleaning the Machine Body Use a soft, damp cloth to clean the exterior of the unit. Do not use any soap or solvents.

Filter Maintenance

  1. Unplug the unit
  2. Slide out the filter.
  3. Check the filter for dirt and buildup.
  4. For a Pre-Filter or MERV-8: Clean the filter mesh by vacuuming it or washing with warm water (no soap orcleaners). Gently shake the filter dry, then reinsert it.
  5. For a Carbon, or HEPA Filter: If there is dirt or buildup, replace filter.

Removing the Housing

  1. Remove the screws on the housing.
  2. Remove the screws on the air inlet grill and air outlet grill.
  • Once per year, clean the coils with an approved coil cleaner. •
  • Coil cleaner should be a self-rinsing, foaming cleaner such as WEB® Coil Cleaner.

Limited Warranty

This limited warranty starts from the date of purchase. Abestorm Solutions Inc. warrants to the original purchaser that this Abestorm product is free from manufacturing defects in material or workmanship for the limited warranty period of:

Six (6) Month parts and labor. This includes the shipments charges for replacement parts or unit.

One (1) year parts and labor. This does not include the shipment charge to send the defective product back to be repaired or replaced.

Three (3) years parts and labor on Refrigeration System ONLY (Compressor, Condenser, and evaporator).

Transportation cost, not included

Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser, and evaporator). Transportation cost, not included

This limited warranty is valid only on products purchased from the manufacturer or Abestorm authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. Abestorm Solutions Inc will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service. To receive warranty service, the purchaser must contact Abestorm at (888)276-9833 or sales@abestorm.com. A proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of Abestorm.

Limited Warranty Exclusions

This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following: