MRCARTOOL L202 Digital Manifold Gauge Set Low Pressure Single Meter Refrigerant User Manual

June 11, 2024
MRCARTOOL

MRCARTOOL L202 Digital Manifold Gauge Set Low Pressure Single Meter Refrigerant User Manual
MRCARTOOL L202 Digital Manifold Gauge Set Low Pressure Single Meter
Refrigerant

Copyright Information

All rights reserved by SHENZHEN SHANGJIA TECH. CO., LTD. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of MRCARTOOL. The information contained herein is designed only for the use of this unit. MRCARTOOL is not responsible for any use of this information as applied to other units.

Neither MRCARTOOL nor its affiliates shall be liable to the purchaser of this unit or third parties for damages, losses, costs, or expenses incurred by purchaser or third parties as a result of: accident, misuse, or abuse of this unit, or unauthorized modifications, repairs, or alterations to this unit, or failure to strictly comply with MRCARTOOL operating and maintenance instructions.

MRCARTOOL shall not be liable for any damages or problems arising from the use of any options or any consumable products other than those designated as Original MRCARTOOL Products or MRCARTOOL Approved Products by MRCARTOOL.

Other product names used herein are for identification purposes only and may be trademarks of their respective owners. MRCARTOOL disclaims any and all rights in those marks.

This unit is made for the purpose of persons who have special techniques and certifications.

Manual are either trademarks, registered trademarks, service marks, domain names, logos, company names of or are otherwise the property of MRCARTOOL or its affiliates. In countries where any of the MRCARTOOL trademarks, service marks, domain names, logos and company names are not registered, MRCARTOOL claims other rights associated with unregistered trademarks, service marks, domain names, logos, and company names. Other products or company names referred to in this manual may be trademarks of their respective owners. You may not use any trademark, service mark, domain name, logo, or company name of MRCARTOOL or any third party without permission from the owner of the applicable trademark, service mark, domain name, logo, or company name. You may contact MRCARTOOL by visiting MRCARTOOL at
https://www.mrcartool.net, or writing to aftersale@mrcartool.net, to request written permission to use Materials on this manual for purposes or for all other questions relating to this manual.

Digital refrigerant gauge adopts the most advanced digital circuit and the high precision pressure sensor, used for both high accuracy refrigerant pressure and vacuum pressure,90 refrigerants build-in according to NIST standard refrigerants pressure and temperature relationship database, real- time test of pressure got relative temperature which can help you more convenient for refrigeration system installation or servicing.

PRODUCT FEATURES

  • Built-in 90 refrigerants and corresponding temperatures sheet data according to the US NIST standard.
  • There modes: refrigerant pressure mode, vacuum percentage mode, leak detection mode.
  • Real-time vacuum pressure test and percent indicate.
  • Pressure units: KPa,Bar,PSI,InHg,KgF/cm2
  • Temperature units: ℃,℉
  • Test range: 0 KPa~6000 KPa
  • Resolution: 1KPa
  • Accuracy: ±0.5%
  • Overload: 10MPa
  • Operating temp: -20℃~60℃
  • Auto power off function:10min(POWER ON/OFF switchable, default POWER ON).

WORKING MODES

The system comes with three common working modes: refrigerant pressure mode, vacuum percentage mode, leak detection mode. The interfaces of different working modes are as follows:

REFRIGERANT PRESSURE MODE

Refrigerant pressure mode

VACUUM PERCENTAGE MODE

Vacuum pressure mode
Vacuum pressure mode

SINGLE DIGITAL MANIFOLD IMAGE AS FOLLOW **

**

Singe Digital

OPERATING INSTRUCTIONS

  • ON/OFF
    Short-press the ” ” key to power on,long-press the ” ” key to power off.

  • Backlight
    Short-press the ” ” key to switch the backlight on and off.

  • Working modes switching
    Press ” ” key and ” ” key to switch different working modes.

  • Parameter setting mode
    In the parameter setting mode, you can set the ultimate vacuum, pressure unit, temperature unit, refrigerant type and auto power off function. The corresponding position on the screen will flash when a certain content is selected. Short-press the ” ” key to enter the setting mode, short-press the ” ” key to switch the setting content, press ” ” / ” ” to set the parameters, select and long-press the ”  ” key to save and exit.
    Note: When setting the ultimate vacuum, press the ”  ” key to reset zero.

  • Auto power off settin
    By default,the system automatically turns off after 10 minutes of inactivity. Users can set to cancel the auto power off function.

  • The setting method is as follows:
    In the parameter setting mode, press the ” ” key to switch to “AUTO ON”, and
    then press the ” ” / ” ” key to switch to “AUTO OFF” to turn off. As shown below:
    setting method

VALUE DIGITAL MANIFOLD IMAGE AS FOLLOW

Singe Digital

ROTARY SWITCH OPERATION INSTRUCTIONS:

  • High and low pressure gauge selection
    Blue arrow“ LOW” for low pressure rotary switch, red arrow“ HIGH ” for high pressure rotary switch.

  • digital Single manifold power on/off
    90 degree limit rotary switch,arrow pointing to ON /OFF,red and blue button are all close in clockwise and open in anti-clockwise.

  • 2-Valve digital manifold power on/off
    90 degree limit rotary switch, arrow pointing to ON /OFF, blue button close in clockwise and open in anti- clockwise; red button close in clockwise and open in anti-clockwise.

SINGLE DIGITAL MANIFOLD VACUUMIZE OPERATION INSTRUCTION

  1. Press ” ” to turn on the manifold, and long press” “for 2 seconds to turn on back light.
  2. After starting the machine, press” ” ” ” to switch to the vacuum mode.
  3. Connect air-condition systerm ,digital manifold and vacuum pump as shown in figure.
  4. After open the digital manifold valve, press” “button to zero cleaning.
  5. Turn on the power switch, vacuolize. Note: according to vacuolize result of 13L cylinder, LCD display” 97%”,”98%”…after 3~5 minutes vacuolized. Higher percent means higher vacuum degree.
  6. Checking the LCD display pressure results, if pressure results are stable, that means there are no gas leak in refrigeration system and connections. If pressure results rising, that means somewhere is leaking in refrigeration system or connections. It should be maintained.
  7. After vacuolize work finished, close manifold valve, remove vacuum pump, press ” ” to turn off the gauge.
    Operation Instruction

SINGLE DIGITAL MANIFOLD REFRIGERANT CHARGING OPERATION INSTRUCTION

  1. Press ” ” to turn on the power switch of digital display meter, and long press” “for 2 seconds to turn on the digital display backlight.
  2. After starting the machine, press”  “” “to switch to the pressure mode.
  3. Short press ” ” to enter the setting mode, select pressure unit and temperature unit, short press” “to switch the setting content, press” “/” “to set the parameters, long press” “to save and exit.
  4. Connect cylinder, air- condition system and single digital manifold as shown in figure.
  5. Press ” ” button to zero cleaning.
  6. Open the digital manifold valve, cylinder valve, starting refrigeration system in order.
  7. After refrigerant charging finished, close cylinder valve,digital manifold valve and remove charging hoses.
  8. Press ” ” button, turn off the gauge.

REFRIGERANT CHARGING CONNECTION METHOD IMAGE

REFRIGERATING SYSTEM
Operation Instruction

VALUE DIGITAL MANIFOLD VACUUMIZE AND REFRIGERANT CHARGING OPERATION

INSTRUCTIONV

REFRIGERATION SYSTEM VACUUMIZE OPERATION INSTRUCTION:

  1. Press” “to turn on the manifold, and long press” “for 2 seconds to turn on back light.
  2. After starting the machine, press” ” ” ” to switch to the vacuum mode.
  3. Connect air-condition systerm, digital manifold and vacuum pump as shown in figure.
  4. After open the digital manifold valve,press ” ” button to zero cleaning.
  5. Turn on the power switch, vacuolize. Note: according to vacuolize result of 13L cylinder, LCD display”97%”,”98%”…after 3~5 minutes vacuolized. Higher percent means higher vacuum degree.
  6. Checking the LCD display pressure results, if pressure results are stable, that means there are no gas leak in refrigeration system and connections. If pressure results rising,that means somewhere is leaking in refrigeration system or connections. It should be maintained.
  7. After vacuolize work finished, close manifold valve, remove vacuum pump, press ” ” to turn off the gauge.
    Operation Instruction

AFTER VACUUMIZE,REFRIGERANT CHARGING OPERATION INSTRUCTION:

  1. Connect cylinder, air- condition system and single digital manifold as shown in figure.
  2. Press ” ” to turn on the power switch of digital display meter, and long press ” ” for 2 seconds to turn on the digital display back light.
  3. After starting the machine, press” ” ” “to switch to the pressure mode.
  4. Short press” “to enter the setting mode, select pressure unit and temperature unit, short press” “to switch the setting content, press” ” / ” “to set the parameters, long press ” ” to save and exit.
  5. Press ”  ****” button to zero cleaning.
  6. Open the digital manifold valve on the left (blue button),cylinder valve, starting refrigeration system in order.
  7. After refrigerant charging finished, close cylinder valve, digital manifold valve and remove charging hoses.
  8. Open the digital manifold valve on the right(red button),test refrigeration system pressure.
  9. After the refrigeration system runs normally, close the digital manifold valve, press ” ” button, turn off the gauge.
    Operation Instruction

TECHNICAL PARAMETER

REFRIGERANT DATA AS FOLLOW FOR DIGITAL MANIFOLD

S/N| Refrigerant| S/N| Refrigerant| S/N| Refrigerant| S/N| Refrigerant| S/N| Refrigerant
---|---|---|---|---|---|---|---|---|---
1| R11| 19| R21| 37| R403B| 55| R414A| 73| R426A
2| R12| 20| R218| 38| R404A| 56| R414B| 74| R427A
3| R13| 21| R22| 39| R405A| 57| R415A| 75| R428A
4| R14| 22| R227EA| 40| R406A| 58| R415B| 76| R500
5| R113| 23| R23| 41| R407A| 59| R416A| 77| R501
6| R114| 24| R236EA| 42| R407B| 60| R417A| 78| R502
7| R115| 25| R245CA| 43| R407C| 61| R418A| 79| R503
8| R116| 26| R245FA| 44| R407D| 62| R419A| 80| R504
9| R123| 27| R290| 45| R407E| 63| R420A| 81| R507A
10| R124| 28| R32| 46| R408A| 64| R421A| 82| R508A
11| R125| 29| RC318| 47| R409A| 65| R421B| 83| R508B
12| R1270| 30| R41| 48| R409B| 66| R422A| 84| R509A
13| R134A| 31| R401A| 49| R410A| 67| R422B| 85| R50
14| R141B| 32| R401B| 50| R410B| 68| R422C| 86| R600
15| R142B| 33| R401C| 51| R411A| 69| R422D| 87| R600A
16| R143A| 34| R402A| 52| R411B| 70| R423A| 88| R717
17| R152A| 35| R402B| 53| R412A| 71| R424A| 89| R744
18| R170| 36| R403A| 54| R413A| 72| R425A| 90| R1234YF

MAINTENANCE AND MAINTENANCE

  1. Please operate according to the requirements of operating instructions or the guidance of professional personnel.
  2. The digital gauge should be keept clean, the display screen should be bright and clear, so that the data on the display screen clearly.Use slightly alkaline detergent or soapy water to wash the case and connector.
  3. The pressure gauge is perishable goods,need to checking regularly to ensure its accuracy.
  4. Handled gently , to prevent shock and fall.
  5. After use, please close all the button, to improve the service life .
  6. Plug the joint when not use,to prevent foreign body from entering, clean and replace regularly refrigerant tube, remove dirt and impurities in valve.

SHENZHEN SHANGJIA TECH CO., LTD

 www.mrcartool.net
 aftersale@mrcartool.net
+86-755-27807580
Shenhua Innovation Park, Shenzhen, China

**Symbols


**

MRCARTOOL Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals