MEAN WELL RSD-30 Series 30W Reliable Railway DC-DC Converter Instruction Manual

June 11, 2024
MEAN WELL

MEAN WELL RSD-30 Series 30W Reliable Railway DC-DC Converter Instruction Manual
MEAN WELL RSD-30 Series 30W Reliable Railway DC-DC
Converter

QR Code

Features

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • Ultra compact and 1U low profile(25mm)
  • 4:1 wide input range
  • No minimum load required
  • Protections: Short circuit / Overload / Over voltage / Input reverse polarity
  • 4000VDC I/O isolation (reinforced isolation)
  • Half encapsulated , cooling by free air convection
  • 40~+70℃ wide working temperature
  • Built-in constant current limiting circuit
  • LED indicator for power on
  • 3 years warranty

Symbols

Applications

  • Bus,tram,metro or railway system
  • Wireless network
  • Telecom or datacom system
  • Highly vibrating, highly dusty, extremely low or high temperature harsh environment

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

RSD-30 is a 30W enclosed type DC-DC reliable railway converter. This series is compliant with BS EN/EN50155/
IEC60571 railway standard, constituting three types of models with 4:1 wide but different input ranges 9~36V/18~72V/40~160V, suitable for railway and all kinds of transportation systems exploiting the frequently used standard input voltages such as 12V, 24V, 36V, 48V, 72V, 96V and 110V. Various output voltages, 3.3V, 5V, 12V and 24V are available for selection.
This series has the capability of working under -40~+70℃, low ripple and noise, supreme EMC characteristics, 4KVDC I/P-OP, low enclosure profile 25mm and an interior with semi-potted silicone. It does not only well fits the in- car systems or the facilities by rails for railway, trams and buses but also can be used in the harsh environment with high vibration, high dust, extremely low or high temperature, etc.

Model Encoding

Model Encoding

SPECIFICATION

MODEL| | RSD-30G-3.3| RSD-30G-5| RSD-30G-12| RSD- 30G-24| RSD-30L-3.3| RSD-30L-5| RSD-30L-12| RSD-30L-24
---|---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 12V| 24V| 3.3V| 5V| 12V| 24V
RATED CURRENT| 6A| 6A| 2.5A| 1.25A| 6A| 6A| 2.5A| 1.25A
CURRENT RANGE| 0 ~ 6A| 0 ~ 6A| 0 ~ 2.5A| 0 ~ 1.25A| 0 ~ 6A| 0 ~ 6A| 0 ~ 2.5A| 0 ~ 1.25A
RATED POWER| 19.8W| 30W| 30W| 30W| 19.8W| 30W| 30W| 30W
RIPPLE & NOISE (max.) Note.2| 70mVp-p| 70mVp-p| 60mVp-p| 50mVp-p| 70mVp-p| 70mVp-p| 60mVp-p| 50mVp-p
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.3%| ±0.2%| ±0.5%| ±0.5%| ±0.3%| ±0.2%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.3%| ±0.2%| ±0.5%| ±0.5%| ±0.3%| ±0.2%
SETUP, RISE TIME| 120ms, 85ms at full load
HOLD UP TIME (Typ.)| Please refer to page 5 Hold up Time( Load de-rating curve )
INPUT| VOLTAGE RANGE CONTINUOUS| 9 ~ 36VDC| 18 ~ 72VDC
EFFICIENCY (Typ.)| 84%| 84%| 86.5%| 89%| 84%| 86%| 90%| 91%
DC CURRENT (Typ.)| 1.1A/24V| 1.5A/24V| 0.52A/48V| 0.8A/48V
INRUSH CURRENT (Typ.)| 20A/24VDC| 20A/48VDC
**INTERRUPTION OF VOLTAGE SUPPLY| EN50155:2007-G type comply with S1 level(3ms) @full load,S2 level(10ms) @80% load; L type comply with S2 level(10ms) @full load
EN50155:2017-Comply with  S1 level
PROTECTION| OVERLOAD| 105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.8 ~ 4.5V| 5.75 ~ 7V| 13.8 ~ 16.2V| 27.6 ~ 32.4V| 3.8 ~ 4.5V| 5.75 ~ 7V| 13.8 ~ 16.2V| 27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -40 ~ +55℃ (no derating) ; +70℃ @ 60% load by free air convection ; +70℃ (no derating with external base plate)
WORKING HUMIDITY| 5 ~ 95% RH non-condensing
STORAGE TEMP.| -40 ~ +85℃
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
OPERATING ALTITUDE| 5000 meters
SAFETY & **EMC (Note 4)| SAFETY STANDARDS| IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE| I/P-O/P:4KVDC   I/P-FG:2.5KVDC   O/P-FG:2.5KVDC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032| Class A
Radiated| BS EN/EN55032| Class B
Harmonic Current| BS EN/EN61000-3-2| —–
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55035
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, ±8KV air ; Level 3, ±6KV contact
Radiated Field| BS EN/EN61000-4-3| Level X, 20V/m
EFT / Burst| BS EN/EN61000-4-4| Level 3, 2KV at power
Level 4, 2KV at signal
Surge| BS EN/EN61000-4-5| Level 3,1KV Line-Line, Level 3, 2KV Line-Earth
Conducted| BS EN/EN61000-4-6| Level 3
RAILWAY STANDARD| Compliance to BS EN/EN45545-2 for fire protection ;BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC
OTHERS| MTBF| 3093.5K hrs min.       Telcordia SR-332 (Bellcore) ; 396.9K hrs min.   MIL-HDBK-217F (25℃)
DIMENSION| 1136025mm (LWH)
PACKING| 0.25Kg; 56pcs/15Kg/0.81CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 24,48VDC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  5. Strongly recommended that external output capacitance should not exceed 5000uF.
  6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
    Product Liability Disclaimer: For detailed information, please refer to

https://www.meanwell.com/serviceDisclaimer.aspx

MODEL RSD-30H-3.3 RSD-30H-5 RSD-30H-12 RSD-30H-24
OUTPUT DC VOLTAGE 3.3V 5V 12V
RATED CURRENT 6A 6A 2.5A 1.25A
CURRENT RANGE 0 ~ 6A 0 ~ 6A 0 ~ 2.5A 0 ~ 1.25A
RATED POWER 19.8W 30W 30W 30W
RIPPLE & NOISE (max.) **Note.2** 70mVp-p 70mVp-p 60mVp-p 50mVp-p
VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.5% ±0.3% ±0.2%
LOAD REGULATION ±0.5% ±0.5% ±0.3% ±0.2%
SETUP, RISE TIME 120ms, 85ms at full load
HOLD UP TIME (Typ.) Please refer to page 5 Hold up Time( Load de-rating

curve )
INPUT| VOLTAGE RANGE CONTINUOUS| 40 ~ 160VDC
EFFICIENCY (Typ.)| 87%| 87%| 89%| 89%
DC CURRENT (Typ.)| 0.23A/110V| 0.35A/110V
INRUSH CURRENT (Typ.)| 20A/110VDC
**INTERRUPTION OF VOLTAGE SUPPLY| EN50155:2007-H-type comply with S2 level(10ms) @ full load
EN50155:2017-Comply with S1 level
PROTECTION| ****OVERLOAD| 105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
****
OVER VOLTAGE| 3.8 ~ 4.5V| 5.75 ~ 7V| 13.8 ~ 16.2V| 27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -40 ~ +55℃ (no derating) ; +70℃ @ 60% load by free air convection ; +70℃ (no derating with external base plate)
WORKING HUMIDITY| 5 ~ 95% RH non-condensing
STORAGE TEMP.| -40 ~ +85℃
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
OPERATING ALTITUDE| 5000 meters
SAFETY & EMC (Note 4)| SAFETY STANDARDS| IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE| I/P-O/P:4KVDC      I/P-FG:2.5KVDC      O/P-FG:2.5KVDC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032| Class A
Radiated| BS EN/EN55032| Class B
Harmonic Current| BS EN/EN61000-3-2| —–
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55035
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, ±8KV air ; Level 3, ±6KV contact
Radiated Field| BS EN/EN61000-4-3| Level X, 20V/m
EFT / Burst| BS EN/EN61000-4-4| Level 3, 2KV at power
Level 4, 2KV at signal
Surge| BS EN/EN61000-4-5| Level 3,1KV Line-Line, Level 3, 2KV Line-Earth
Conducted| BS EN/EN61000-4-6| Level 3
RAILWAY STANDARD| Compliance to BS EN/EN45545-2 for fire protection;BS EN/EN50155 /IEC60571 including IEC61373 for shock & vibration,BS EN/EN50121-3-2 for EMC
OTHERS| MTBF| 3093.5K hrs min.       Telcordia SR-332 (Bellcore) ; 396.9K hrs min.   MIL-HDBK-217F (25℃)
DIMENSION| 1136025mm (LWH)
PACKING| 0.25Kg; 56pcs/15Kg/0.81CUFT
NOTE**|

  1. All parameters NOT specially mentioned are measured at 110VDC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation
  4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  5. Strongly recommended that external output capacitance should not exceed 5000uF.
  6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

Block Diagram

Input Fuse

There is one fuse connected in series to the positive input line, which is used to protect against abnormal surge. Fuse specifications of each model are shown as below.

Type Fuse Type Reference and Rating
G Time-Lag CONQUE MST, 6.3A, 250V
L Time-Lag CONQUE MST, 3.15A, 250V
H Time-Lag CONQUE MST, 2A, 250V

Input Reverse Polarity Protection

There is a MOSFET connected in series to the negative input line. If the input polarity is connected reversely, the MOSFET opens and there will be no output to protect the unit.

Input Range and Transient Ability

The series has a wide range input capability. With ±40% of rated input voltage, it can withstand that for 1 second.

Input Under-Voltage Protection

If input voltage drops below Vimin, the internal control IC shuts down and there is no output voltage. It recovers automatically when input voltage reaches above Vimin, please refer to the cruve below.

RSD-30G-24
Input Under-Voltage Protection
RSD-30L-24
Input Under-Voltage Protection
RSD-30H-24
Input Under-Voltage Protection

Inrush Current

Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by a MOSFET to reduce power consumption after accomplishing the start-up.

Hold-up Time

  • EN50155: 2007 version – H type is in compliance with S2 level (10ms), while G and L types are in compliance with S1 level (3ms) at full load output condition. To fulfil the requirements of S2 level (10ms), G types require de-rating their output load to 80%, please refer to the curve diagrams below.

RSD-30G-3.3
Hold-up Time
RSD-30G-5
Hold-up Time
SD-30G-12
Hold-up Time
SD-30G-12
Hold-up Time

EN50155: 2017 version – Comply with S1 level (3ms)

Output Voltage Adjustment

This function is optional, which the standard product does not have it. If you do need the function, please contact MW for details.

Efficiency vs Load & Vin Curve

The efficiency vs load & Vin curves of each model are shown as below

RSD-30G-3.3
Efficiency vs Load Graph
RSD-30G-5
Efficiency vs Load Graph
RSD-30G-12
Efficiency vs Load Graph
RSD-30G-24
Efficiency vs Load Graph
RSD-30L-3.3
Efficiency vs Load Graph
RSD-30L-5
Efficiency vs Load Graph
RSD-30L-12
Efficiency vs Load Graph
RSD-30L-24
Efficiency vs Load Graph
RSD-30H-3.3
Efficiency vs Load Graph
RSD-30H-5
Efficiency vs Load Graph
RSD-30H-12
Efficiency vs Load Graph
RSD-30H-24
Efficiency vs Load Graph

Parallel and Series Connection

A. Operation in Parallel
Since RSD-30 series don’t have built-in parallel circuit, it can only use external circuits to achieve the redundant operation but not increase the current rating

  1. Add a diode at the positive-output of each power supply (as shown as below), the current rating of the diode should be larger than the maximum output current rating and attached to a suitable heat sink. This is only for redundant use (increase the reliability of the system) and users have to check suitability of the circuit by themselves.
    Connection

  2. When using S.P.S. in parallel connection, the leakage current will increase at the same time. This could pose as a shock hazard for the user. So please contact the supplier if you have this kind of application.

B.Operation in Series

RSD-30 can be operated in series. Here are the methods of doing it:

  1. Positive and negative terminals are connected as shown as below. According tothe connection, you can get the positive and negative output voltages for your loads.
    Connection

  2. Increase the output voltage (current does not change). Because RSD-30 series have no reverse blocking diode in the unit, you should add an external blocking diode to prevent the damage of every unit while starting up. The voltage rating of the external diode should be larger than V1+V2 (as shown as below).
    Connection

Overload Protection

If the output draw up to 105~135% of its output power rating, the converter will go into  overload protection which is constant current mode. After the faulty condition is removed, it will recover automatically. Please refer to the diagram below for the detail operation characteristic. Please note that it’s not suitable to operate within the overload region continuously, or it may cause to over temperature and reduce the life of the power supply unit or even damage it.

Overload Protection

Over Voltage Protection

The converter shuts off to protect itself when the output voltage drawn exceeds 115~140% of its output rating. It must be repowered on to recover.

LED Indicator

Equipped with a built-in LED indicator, the converter provides an easy way for users to check its condition through the LED indicator.
Green : normal operation; No signal: no power or failure.

Derating Curve

a. Single unit operation

If the unit has no iron plate mounted on its bottom, the maximum ambient temperature for the unit will be 55℃ as operating under full load condition. It requires de-rating output current when ambient temperature is between 55~70℃, please refer to the de-rating curve as below.

AMBIENT TEMPERATURE (℃)
Derating Curve
Tcase (℃)
Derating Curve

Suitable installation methods are shown as below. Since RSD-30 is a semi- potted model, its thermal performances for the following installation methods are similar and share the same derating curve.

Derating Curve

b. Operate with additional iron plate

If it is necessary to fulfil the requirements of EN50155 TX level that operate the unit fully-loaded at 70℃, RSD-30 series must be installed onto an iron plate on the bottom. The size of the suggested iron plate is shown as below. In order for optimal thermal performance, the iron plate must have an even & smooth surface and RSD-30 series must be firmly mounted at the center of the iron plate.

Dimensions

The load vs ambient temperature curve is shown as below.

Ambient Temperature
AMBIENT TEMPERATURE (℃)

Suitable installation methods are shown as below. Since RSD-30 is a semi- potted model, its thermal performances for the following installation methods are similar and share the same derating curve.

Derating Curve

Immunity to Environmental Conditions

Test method Standard Test conditions Status
Cooling Test EN 50155 section 12.2.3 (Column 2, Class TX)EN 60068-2-1
Temperature: -40℃Dwell Time: 2 hrs/cycle No damage
__ Dry Heat Test EN 50155 section 12.2.4 (Column 2, Class TX)EN 50155
section 12.2.4 (Column 3, Class TX & Column 4, Class TX) EN 60068-2-2
Temperature: 70℃ / 85℃ Duration: 6 hrs / 10min __ PASS
__ Damp Heat Test, Cyclic EN 50155 section 12.2.5EN 60068-2-30 Temperature:
25℃~55℃ Humidity: 90%~100% RH Duration: 48 hrs __ PASS
__ Vibration Test EN 50155 section 12.2.11EN 61373 Temperature: 19℃
Humidity: 65%Duration: 10 mins __ PASS
__ Increased Vibration Test EN 50155 section 12.2.11EN 61373 Temperature:
19℃ Humidity: 65%Duration: 5 hrs __ PASS
__ Shock Test EN 50155 section 12.2.11EN 61373 Temperature: 21± 3℃
Humidity: 65 ± 5%Duration: 30ms*18 __ PASS
__ Low Temperature Storage Test EN 50155 section 12.2.3 (Column 2, Class
TX)EN 60068-2-1 Temperature: -40℃ Dwell Time: 16 hrs __ PASS
__ Salt Mist Test __ EN 50155 section 12.2.10 (Class ST4) Temperature:
35℃±2℃ Duration: 96 hrs __ PASS

EN45545-2 Fire Test Conditions

Test Items Hazard Level
Items Standard
R24 Oxygen index test
PASS PASS
R25 Glow-wire test

PASS
R26| Vertical flame test| EN 45545-2:2013+A1:2015 EN 60695-11:2003| PASS| PASS| PASS

Mechanical Specification

Dimensions

Dimensions

tc : Max. Case Temperature

Input Terminal Pin No. Assignment :

Pin No. Assignment
1 DC INPUT V+
2 DC INPUT V-
3 FG

Output Terminal Pin No. Assignment :

Pin No. Assignment
1 DC OUTPUT -V
2 DC OUTPUT +V

Installation Manual

Please refer to : http://www.meanwell.com/manual.html

Symbols

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals