MEAN WELL NPB-240 Series 40W Compact Size and Wide Output Range Charger Instruction Manual

June 11, 2024
MEAN WELL

NPB-240 Series 40W Compact Size and Wide Output Range Charger
Instruction Manual 240W Compact Size and Wide Output Range Charger
N P B – 2 4 0 series

NPB-240 Series 40W Compact Size and Wide Output Range Charger

Output connector: TB type

Output connector: AD1/XLR type

User’s Manual

https://www.meanwell.com/Upload/PDF/NPB,NPP-E.pdf

Features

  • 90′-264Vac universal AC input, built-in PFC
  • Charger for compatible with lead-acid and li-ion batteries
  • Fan less design
  • Wide adjustable output range by VR:
  • Charging voltage adjustable(10.5-‘15.2V, 21-30.4V, 42-60.8V)
  • Charging current adjustable(50-100% rated current)
  • 2 or 3 stage selectable by DIP S.W
  • No load power consumption< 0.15W(AC S.W off)
  • -30`C -+70 C wide operating temperature
  • Protections: Short circuit / Over voltage /Over temperature / Battery reverse polarity protection
  • Comply with UL/EN62368-1 and EN60335-1/2-29 dual certification
  • Front panel LED indicator for charging status
  • 3 years warranty

Applications

  • Radio system backup solution
  • Electric scooter charger
  • Camping car
  • Buses Heavy duty truck Specialty vehicles
  • Surveillance system
  • Portable power tools

GTIN CODE

MW Search. httos://www.meanwell.comfserviceGTIN.aspx

Description

NPB-240 series is a 240W charger for compatible with lead-acid (Flooded, Gel, AGM) and li-ion(Lithium iron, lithium manganese) batteries. This product is a class I power unit (with FG), equipped with a standard IEC320-C14 AC inlet and two or three-stage charging control. The entire series supplies different models with output voltages ranging between 10.5VDC and 60.8VDC that can satisfy the demands for various types of batteries devices.
Model Encoding

Type Output Connector Safety Note
XLR 4 pin power pin           ln Stock
AD1 Anderson Equivalent Connector ln Stock
TB Terminal Block ln Stock

SPECIFICATION

MODEL NPB-240-12 NPB-240-24 NPB-240-48

=XLR, AD1, TB
OUTPUT| BOOST CHARGE **VOLTAGE(Boost)(default)| 14.4V| 28.8V| 57.6V
FLOAT CHARGE ****VOLTAGE(Float)(default)| 13.8V| 27.6V| 55.2V
VOLTAGE ADJUSTABLE RANGE| 10.5 ~ 15.2V| 21 ~ 30.4V| 42 ~ 60.8V
OUTPUT CURRENT(Typ.) ****Note.5| 13.5A| 8A| 4A
CURRENT ADJUSTABLE RANGE| 50% ~ 100%
MAX. POWER Note.3| 205.2W| 243.2W| 243.2W
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.4| 55 ~ 180AH| 30 ~ 100AH| 15 ~ 50AH
LEAKAGE CURRENT FROM BATTERY (Typ.)| <1mA
INPUT| VOLTAGE RANGE Note.5| 90 ~ 264VAC        127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)**| PF>0.98/115VAC, PF>0.95/230VAC at full load


EFFICIENCY (Typ.)

| XLR| 88.5%| 92%| 92.5%
AD1| 88.5%| 92%| 92.5%
TB| 89%| 92%| 93%
AC CURRENT (Typ.)| 3A/115VAC        1.5A/230VAC
INRUSH CURRENT (Typ.)| COLD START  50A at 230VAC
LEAKAGE CURRENT| <0.75mA/240VAC
PROTECTION| SHORT CIRCUIT Note.6| Protection type : Constant current limiting, charger will shutdown after 5 sec, re-power on to recover
OVER VOLTAGE| 16 ~ 20V| 32 ~ 40V| 64 ~ 75V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
REVERSE POLARITY| By internal fuse open
OVER TEMPERATURE| Hiccup mode, recovers automatically after temperature goes down
FUNCTION| CHARGING CURVE| 2 or 3 stage adjustable by DIP S.W
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 45℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & **EMC**

(Note 7)

| SAFETY STANDARDS| CB IEC62368-1,IEC60335-1/2-29, Deka BS EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, AS/NZS60335-1/2-29, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Radiated| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55014-2,BS EN/EN55024,BS EN/EN55035
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2, 3V/m
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2, 3Vrms
Magnetic Field| BS EN/EN61000-4-8| Level 1, 1A/m
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods


OTHERS

| MTBF| 1284.9K hrs min. Telcordia TR/SR-332 (Bell core) ; 157.5K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 182.79649mm (LWH)
PACKING| 1.3Kg; 10pcs/ 14Kg / 1.13CUFT
NOTE| 1.  Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. Refer to derating curve.
4. This is MEAN WELL’s suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
7. The charger is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMl testing of component power supplies. (as available on http://www.meanwell.com)
※ Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)

Block Diagram

Derating Curve

Static Characteristics

Function Manual
1.Charging Curve
1-1 2 or 3 stage selectable by DIP S.W
※ This series provides 2 or 3 stage charging curve.(Default 3 stage)

1-2 Charging Curve by DIP S.W
◎ 2 stage charging curve

State NPB-240-12 NPB-240-24 NPB-240-48
Constant Current 13.5A 8A 4A
Float 13.8V 27.6V 55.2V

◎ 3 stage charging curve

State NPB-240-12 NPB-240-24 NPB-240-48
Constant Current 13.5A 8A 4A
Boost 14.4V 28.8V 57.6V
Float 13.8V 27.6V 55.2V

◎ 2 stage charging cure is suitable for Li-ion batteries(lithium iron and lithium manganese),
3 stage charging cure is suitable for lead-acid batteries (flooded ,Gel and AGM).
2.Charging voltage adjustable by VR

Model NPB-240-12 NPB-240-24 NPB-240-48
Output voltage adjustable range 10.5~15.2V 21~30.4V 42~60.8V

3.Charging current adjustable by VR

Model NPB-240-12 NPB-240-24 NPB-240-48
Output current adjustable range 6.75~13.5A 4~8A 2~4A

4. Front panel LED indicators & Corresponding signal at function pins

LED

| Description
---|---

Green

| Float (stage 3) or Battery full

 Red

| Charging (stage 1 or stage 2)

Mechanical Specification

◎ NPB-240-xx XLR/AD1 (Cable Type)

◎ NPB-240-xx TB (Terminal Block Type)

Accessory List
※ Bracket (Optional accessory, Should ordered separately )

MW’s Order No.

| Item| Quantity
---|---|---
DGG2MHS012D| |

4pcs/per model

Installation Diagram

Plug Assignment
◎ Standard Output Connector

4pin XLR

UNICABLE 89M103-4P or equivalent


| PIN NO.| OUTPUT
1,2| +V
3,4| -V
AD1
housing: Anderson 1327(red), 1327G6(black) equivalent contacts: Anderson 261G2 (45A) equivalent

Red(+V)    Black(-V)

TB
DT-66-B11W-02 or equivalent Rating: 300V 40A

◎ Optional DC plug: (Available in customized )

Min. DIN 4 Pin with Lock (male)

| Type No.| Pin Assignment
---|---|---
PIN No.| Output(<7A)
|

R7B

| 1| +Vo
2| -Vo
3| -Vo
4| +Vo

DIN 3 Pin XLR

| Type No.| Pin Assignment
PIN No.| Output(<10A)
|

XLR3

| 1| +Vo
2| +Vo
3| -Vo

DIN 3 Pin

| Type No.| Pin Assignment
PIN No.| Output(<7A)
| D3P| 1| +Vo
2| -Vo
3| -Vo

DIN 2 Pin

| Type No.| Pin Assignment
PIN No.| Output(<5A)
|

D2P

| 1| -Vo
2| +Vo

DIN 3 Pin

| Type No.| Pin Assignment
PIN No.| Output(<10A)
|

INL3

| N| +Vo
L| -Vo
AMP 1-480702-0 (6.35mm) equivalent| Type No.| Pin Assignment
PIN No.| Output(<7A)
| C4P| 1| +Vo
2| +Vo
3| -Vo
4| -Vo

INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals