Features
- 90′-264Vac universal AC input, built-in PFC
- Charger for compatible with lead-acid and li-ion batteries
- Fan less design
- Wide adjustable output range by VR:
- Charging voltage adjustable(10.5-‘15.2V, 21-30.4V, 42-60.8V)
- Charging current adjustable(50-100% rated current)
- 2 or 3 stage selectable by DIP S.W
- No load power consumption< 0.15W(AC S.W off)
- -30`C -+70 C wide operating temperature
- Protections: Short circuit / Over voltage /Over temperature / Battery reverse polarity protection
- Comply with UL/EN62368-1 and EN60335-1/2-29 dual certification
- Front panel LED indicator for charging status
- 3 years warranty
Applications
- Radio system backup solution
- Electric scooter charger
- Camping car
- Buses Heavy duty truck Specialty vehicles
- Surveillance system
- Portable power tools
GTIN CODE
MW Search. httos://www.meanwell.comfserviceGTIN.aspx
Description
NPB-240 series is a 240W charger for compatible with lead-acid (Flooded, Gel,
AGM) and li-ion(Lithium iron, lithium manganese) batteries. This product is a
class I power unit (with FG), equipped with a standard IEC320-C14 AC inlet and
two or three-stage charging control. The entire series supplies different
models with output voltages ranging between 10.5VDC and 60.8VDC that can
satisfy the demands for various types of batteries devices.
Model Encoding
Type | Output Connector | Safety | Note |
---|---|---|---|
XLR | 4 pin power pin | ln Stock | |
AD1 | Anderson Equivalent Connector | ln Stock | |
TB | Terminal Block | ln Stock |
SPECIFICATION
MODEL | NPB-240-12 | NPB-240-24 | NPB-240-48 |
---|
=XLR, AD1, TB
OUTPUT| BOOST CHARGE **VOLTAGE(Boost)(default)| 14.4V|
28.8V| 57.6V
FLOAT CHARGE ****VOLTAGE(Float)(default)| 13.8V| 27.6V| 55.2V
VOLTAGE ADJUSTABLE RANGE| 10.5 ~ 15.2V| 21 ~ 30.4V| 42 ~ 60.8V
OUTPUT CURRENT(Typ.) ****Note.5| 13.5A| 8A| 4A
CURRENT ADJUSTABLE RANGE| 50% ~ 100%
MAX. POWER Note.3| 205.2W| 243.2W| 243.2W
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.4| 55 ~ 180AH| 30
~ 100AH| 15 ~ 50AH
LEAKAGE CURRENT FROM BATTERY (Typ.)| <1mA
INPUT| VOLTAGE RANGE Note.5| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)**| PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.)
| XLR| 88.5%| 92%| 92.5%
AD1| 88.5%| 92%| 92.5%
TB| 89%| 92%| 93%
AC CURRENT (Typ.)| 3A/115VAC 1.5A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A at 230VAC
LEAKAGE CURRENT| <0.75mA/240VAC
PROTECTION| SHORT CIRCUIT Note.6| Protection type : Constant
current limiting, charger will shutdown after 5 sec, re-power on to recover
OVER VOLTAGE| 16 ~ 20V| 32 ~ 40V| 64 ~ 75V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
REVERSE POLARITY| By internal fuse open
OVER TEMPERATURE| Hiccup mode, recovers automatically after temperature
goes down
FUNCTION| CHARGING CURVE| 2 or 3 stage adjustable by DIP S.W
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 45℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & **EMC**
(Note 7)
| SAFETY STANDARDS| CB IEC62368-1,IEC60335-1/2-29, Deka BS
EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, AS/NZS60335-1/2-29, EAC TP TC
004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Radiated| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55014-2,BS EN/EN55024,BS EN/EN55035
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2, 3V/m
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2, 3Vrms
Magnetic Field| BS EN/EN61000-4-8| Level 1, 1A/m
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods, >95% interruptions 250 periods
OTHERS
| MTBF| 1284.9K hrs min. Telcordia TR/SR-332 (Bell core) ; 157.5K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 182.79649mm (LWH)
PACKING| 1.3Kg; 10pcs/ 14Kg / 1.13CUFT
NOTE| 1. Modification for charger specification may be required for
different battery specification. Please contact battery vendor and MEAN WELL
for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated
load and 25℃ of ambient temperature.
3. Refer to derating curve.
4. This is MEAN WELL’s suggested range. Please consult your battery
manufacturer for their suggestions about maximum charging current limitation.
5. Derating may be needed under low input voltages. Please check the derating
curve for more details.
6. This protection mechanism is specified for the case the short circuit
occurs after the charger is turned on.
7. The charger is considered a component which will be installed into a final
equipment. The final equipment must be re-confirmed that it still meets EMC
directives. For guidance on how to perform these EMC tests, please refer to
EMl testing of component power supplies. (as available on
http://www.meanwell.com)
※ Product Liability Disclaimer:For detailed information, please refer to
https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
Block Diagram
Derating Curve
Static Characteristics
Function Manual
1.Charging Curve
1-1 2 or 3 stage selectable by DIP S.W
※ This series provides 2 or 3 stage charging curve.(Default 3 stage)
1-2 Charging Curve by DIP S.W
◎ 2 stage charging curve
State | NPB-240-12 | NPB-240-24 | NPB-240-48 |
---|---|---|---|
Constant Current | 13.5A | 8A | 4A |
Float | 13.8V | 27.6V | 55.2V |
◎ 3 stage charging curve
State | NPB-240-12 | NPB-240-24 | NPB-240-48 |
---|---|---|---|
Constant Current | 13.5A | 8A | 4A |
Boost | 14.4V | 28.8V | 57.6V |
Float | 13.8V | 27.6V | 55.2V |
◎ 2 stage charging cure is suitable for Li-ion batteries(lithium iron and
lithium manganese),
3 stage charging cure is suitable for lead-acid batteries (flooded ,Gel and
AGM).
2.Charging voltage adjustable by VR
Model | NPB-240-12 | NPB-240-24 | NPB-240-48 |
---|---|---|---|
Output voltage adjustable range | 10.5~15.2V | 21~30.4V | 42~60.8V |
3.Charging current adjustable by VR
Model | NPB-240-12 | NPB-240-24 | NPB-240-48 |
---|---|---|---|
Output current adjustable range | 6.75~13.5A | 4~8A | 2~4A |
4. Front panel LED indicators & Corresponding signal at function pins
LED
| Description
---|---
Green
| Float (stage 3) or Battery full
Red
| Charging (stage 1 or stage 2)
Mechanical Specification
◎ NPB-240-xx XLR/AD1 (Cable Type)
◎ NPB-240-xx TB (Terminal Block Type)
Accessory List
※ Bracket (Optional accessory, Should ordered separately )
MW’s Order No.
| Item| Quantity
---|---|---
DGG2MHS012D| |
4pcs/per model
Installation Diagram
Plug Assignment
◎ Standard Output Connector
4pin XLR
UNICABLE 89M103-4P or equivalent
| PIN NO.| OUTPUT
1,2| +V
3,4| -V
AD1
housing: Anderson 1327(red), 1327G6(black) equivalent contacts: Anderson
261G2 (45A) equivalent
Red(+V) Black(-V)
TB
DT-66-B11W-02 or equivalent Rating: 300V 40A
◎ Optional DC plug: (Available in customized )
Min. DIN 4 Pin with Lock (male)
| Type No.| Pin Assignment
---|---|---
PIN No.| Output(<7A)
|
R7B
| 1| +Vo
2| -Vo
3| -Vo
4| +Vo
DIN 3 Pin XLR
| Type No.| Pin Assignment
PIN No.| Output(<10A)
|
XLR3
| 1| +Vo
2| +Vo
3| -Vo
DIN 3 Pin
| Type No.| Pin Assignment
PIN No.| Output(<7A)
| D3P| 1| +Vo
2| -Vo
3| -Vo
DIN 2 Pin
| Type No.| Pin Assignment
PIN No.| Output(<5A)
|
D2P
| 1| -Vo
2| +Vo
DIN 3 Pin
| Type No.| Pin Assignment
PIN No.| Output(<10A)
|
INL3
| N| +Vo
L| -Vo
AMP 1-480702-0 (6.35mm) equivalent| Type No.| Pin Assignment
PIN No.| Output(<7A)
| C4P| 1| +Vo
2| +Vo
3| -Vo
4| -Vo
INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>