NEO NAS-WS09Z8U Water Sensor User Manual

June 9, 2024
NEO

NEO NAS-WS09Z8U Water Sensor

NEO NAS-WS09Z8U-Water-Sensor-PRODUCT

INFORMATION

  • Model: NAS-WS09Z8U
  • Z-Wave Version: 700s S2
  • Version: 1.0 1.1
  • Written By: Yongqi Yongqi
  • Date: 20191217 20201127
  • Change List: Initial Modify Some Errors

Product Information

The Water Leakage Detector is a Z-WaveTM-enabled device that can be included and operated in any Z-WaveTM network with other Z-WaveTM certified devices from other manufacturers and/or other applications. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. The device supports 2 association groups, and each group supports max 5 associated nodes.

Z-WaveTM Network Inclusion/Exclusion/Reset

To include, exclude, or reset the Water Leakage Detector from a Z-WaveTM network, perform the following steps:

  1. Power up the device.
  2. Set Z-WaveTM Controller into inclusion mode. The blue LED will blink at 1s intervals until inclusion.
  3. Press and hold the button for 5s until white LED light is on,then release the button before LED turn off. The device has been successfully included.
  4. To exclude the device, set Z-WaveTM Controller into exclusion mode. The blue LED will blink with 0.5s intervals until exclusion is successful.
  5. Press and hold the button for 5s until white LED lights is on, then release the button before LED turn off.
  6. To reset the device, press and hold the button for 10s until pink LED lights is on, then release the button before LED turn off.

Product Test Mode

To enter the factory product test mode, perform the following steps:

  1. Press and hold the button.
  2. Power on the device.
  3. The device will enter into factory product test mode with white light blink one time.
  4. Press and hold the button for 5s until white LED lights is on, then release the button before LED turn off.

Association

The device supports 2 association groups:

  • Group 1 (Lifeline): All nodes which associated in this group will receive the messages sent by device through lifeline. The Command Class supported by this group are COMMAND_CLASS_NOTIFICATION, NOTIFICATION_REPORT, COMMAND_CLASS_SENSOR_BINARY, SENSOR_BINARY_REPORT, COMMAND_CLASS_BATTERY, BATTERY_REPORT, COMMAND_CLASS_INDICATOR, and COMMAND_CLASS_DEVICE_RESET_LOCALLY.
  • Group 2 (Control): All nodes associated in this group will be controlled through the BASIC_SET command by the device when device detects a water leakage event. The Command Class supported by this group is COMMAND_CLASS_BASIC and BASIC_SET.

Z-WaveTM Message Report

Once the device detects a water leakage event, it will report the event to the controller. In default, device will use COMMAND_CLASS_NOTIFICATION to represent the water leakage event. User can also enable COMMAND_CLASS_SENSOR_BINARY report by setting Configuration No.9 to `1′. Notice 1: If device is not added in any Z-Wave network, it will be beep alarm always until the battery is running down, and the parameter settings (Configuration Parameter 1 to 4) are invalid.

Version Written By Date Change List
1.0 Yongqi 20191217 Initial
1.1 Yongqi 20201127 Modify Some Errors

The Water Leakage Detector is a Z-Wave™ enabled device and is fully compatible with any Z-Wave™ enabled network. Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave™ enable networks.
This product can be included and operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Z-Wave™ Network Inclusion/Exclusion/Reset

Remove the sensor casing, there is one button on the top side of PCB board, it can be executed inclusion, exclusion and reset from Z-Wave™ network.

Add¹

| 1、 Power up the device.

2、 Set Z-Wave™ Controller into inclusion mode 3 、 Press and hold the button for 5s until white led lights is on, then release the button

before led turn off.

|

Blue led will blink with 1s interval until inclusion successful.

---|---|---

Remove

| 1、 Power up the device.

2、 Set Z-Wave™ Controller into exclusion mode 3 、 Press and hold the button for 5s until white led lights is on, then release the button

before led turn off.

|

Blue led will blink with 0.5s interval until exclusion successful.

Factory Reset²

| 1、 Power up the device.

2 、 Press and hold the button for 10s until pink led lights is on, then release the button before led turn off.

|

Product Test Mode

| 1 、 Press and hold the button.

2 、 Power on the device, device will enter into factory product test mode with white light blink one time.

|

Send NIF³

| Press and hold the button for 5s until white led lights is on, then release the button before led turn off.|

Notice 1: When device enters into inclusion mode, the device all functionality will be useless. The inclusion mode will be timeout after 30s, user can implement step 3 to terminate the inclusion mode.
Notice 2 : Factory Reset will clear the device all Z-Wave™ Network data (include home id, node id, etc…) saved in memory, and restore all configuration parameters to factory default. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Notice 3: NIF – Node Information

Association

The device supports 2 association groups, and each group supports max 5 associated nodes. Group 1 is lifeline group; all nodes which associated in this group will receive the messages sent by device through lifeline.
Group 2 is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects a water leakage event.
The Command Class supported by each association group is shown in the table below:

Group Command Class Event
1 (Lifeline) COMMAND_CLASS_NOTIFICATION NOTIFICATION_REPORT
COMMAND_CLASS_SENSOR_BINARY SENSOR_BINARY_REPORT
COMMAND_CLASS_BATTERY BATTERY_REPORT
COMMAND_CLASS_INDICATOR INDICATOR_REPORT
COMMAND_CLASS_DEVICE_RESET_LOCALLY DEVICE_RESET_LOCALLY_NOTIFICATION
2 (Control) COMMAND_CLASS_BASIC BASIC_SET

Z-Wave™ Message Report

  • Once the device detects a water leakage event, it will report the event to the controller.
  • In default, device will use COMMAND_CLASS_NOTIFICATION to represent the water leakage event. User can also enable COMMAND_CLASS_SENSOR_BINARY report by setting the “Configuration No.9” to ‘1’.
  • Notice 1 : If device is not added in any Z-Wave network, it will be beep alarm always until battery is running down, and the parameter settings (Configuration Parameter 1 to  4) are invalid.

Water Leakage Report

When device detects a water leakage event, it will automatically send the notification report to nodes associated in a lifeline.

Command Class COMMAND_CLASS_NOTIFICATION
Command NOTIFICATION_REPORT
Type WATER_ALARM (0x05)
Event WATER_LEAK_DETECTED_UNKNOWN_LOCATION (0x02) WATER_ALARM_NO_EVENT (0x00)
Command Class COMMAND_CLASS_SENSOR_BINARY
Command SENSOR_BINARY_REPORT
Type WATER
Event DETECTED (0xFF) / NO-DETECTED (0x00)

Command Class Configuration

The device supports the controller to configure parameters of the device through Configuration Command Class, and the device has 9 parameters available for users to set according to their different needs:

Alarm Duration Time

This configuration can be used to adjust the time for beep and LED turned on when water leakage is detected. If this configuration is set to ‘0’, the beep and LED will be turn on always until water leakage is not detected. Prefer to Figure 1. Unit: min (Minute).

Parameter Number Size (Byte) Available Settings Default value
1 1 0 ~ 120 120

Alarm Interval Time

This configuration defines beep on /off interval time when water leakage is detected. Prefer to Figure 1. Unit: s (Second).

Parameter Number Size (Byte) Available Settings Default value
2 1 5 ~ 120 60

First Alarm On Time Duration

This configuration defines beep on the duration first time when water leakage is detected. Prefer to Figure 1. Unit: s (Second).

Parameter Number Size (Byte) Available Settings Default value
3 1 10 ~ 120 60

Alarm on Time Duration

This configuration defines beep on duration after first beep when water leakage is detected. Prefer to Figure 1. Unit: s (Second).

Parameter Number Size (Byte) Available Settings Default value
4 1 5 ~ 120 5

Water Leakage Detected Disable

This configuration sets to ‘0’ will disable the water leakage detecting function.

  • Parameter Number 5
  • Size (Byte) 1
  • Available Settings 0.1
  • Default value 1

Beep Alarm Disable

This configuration sets to ‘0’ will disable the beep alarm on when device detects water leakage event.

Parameter Number Size (Byte) Available Settings Default value
6 1 0, 1 1

Led Light Alarm Disable

This configuration sets to ‘0’ will disable the Led indicating when device detects a water leakage event.

Parameter Number Size (Byte) Available Settings Default value
7 1 0, 1 1

Basic Set Level

This configuration sets the level for device sending BASIC_SET to nodes that are associated in group 2 when device detects a water leakage event.

  • [0] – Off, BASIC_SET = 0x00, all nodes associated in group 2 will be off.
  • [1 … 99] – On. BASIC_SET = [Setting Value].
  • [100] – On, BASIC_SET = 0xFF.
Parameter Number Size (Byte) Available Settings Default value
8 1 0 ~ 100 100

Sensor Binary Report Enable

This parameter sets to ‘1’ will enable SENSOR_BINARY_REPORT when device detects a water leakage event. This is for Z-Wave protocol backward compatibility.

Parameter Number Size (Byte) Available Settings Default value
9 1 0 , 1 0

Wakeup Command Class

  • The device stays in sleep status for the majority of time in order to conserve battery life.
  • The minimum wakeup interval is 20s
  • The maximum wakeup interval is 86400s (24 Hours)
  • The allowable min step among each wakeup interval is 60 seconds, such as the 1860s, 1870s,1880s…

Note : The default value is 12 hours with factory default. This value is greater, the battery life is longer.

Battery Command Class

  • The users can also enquire the battery status of the device by sending the BATTERY_GET command.
  • Once the device receivers the command, it will return the BATTERY_REPORT command.
  • The device will send BATTERY_REPORT = 0xFF command to the Z-Wave™ Controller to inform that the device is in dead battery status, otherwise BATTERY_REPORT value range is from 0% to 100%.

Command Class Basic

  • The COMMAND_CLASS_BASIC is realized to control the devices associated in group 2 in this water detector.
  • When water detector detects a water leakage event occurred, it will send a “BASIC_SET = [Value]” command to control the devices in group 2.
  • And it will send a “BASIC_SET = 0x00” command to control the devices in group 2 after the water leakage event is cleared.
  • The [Value] is set by configuration No.8.

SmartStart

SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
This device supports SmartStart function. QR code printed by laser can be found on surface of product and the outside of packing box. And the full DSK code is printed can be found on the packing box.
The device will enter SmartStart if the device is not included in network after power up. And if device is not included successfully during 10 second, it will enter sleep mode. And then

  • 2nd SmartStart time delay approximately 16s
  • 3rd SmartStart time delay approximately 32s
  • 4th SmartStart time delay approximately 64s
  • 5th SmartStart time delay approximately 128s
  • 6th SmartStart time delay approximately 256s
  • 7th SmartStart time delay approximately 512s

Afterwards, the Smartstart mode will be auto running with 512 second interval until device is included successfully or battery run dow

Led Action Indicator

Led Color Action Description
Red Light On 1s When Power On Not Add in Z-Wave Network
Light On Always Water Leakage is Detected
Pink Light On 2s Press And Hold Button 10s, Off at 12th Second
Green Light On 1s When Power On Add in Z-Wave in Network Already
White Light On 2s Press And Hold Button 5s, Off at 7th Second
Blue Blink with 1s Interval Add to Z-Wave Network
Blink with 500ms Interval Remove from Z-Wave Network
Yellow Blink with 500ms Interval OTA is Running
Light On Always Button Pressed and Held Time Large Than 12s.

Security Network

The device supports the security function with S2 encrypted communication. The device will auto switch to the security mode when the device included with a security controller. In the security mode, the follow commands must use security and security_2 command class wrapped to communicate, otherwise the device will not response any commands.

Security Keys

This device supports security levels are listed in below table:

Security Levels Support (Yes/No)
SECURITY_KEY_S0 Yes
SECURITY_KEY_S2_UNAUTHENTICATED Yes
SECURITY_KEY_S2_AUTHENTICATED Yes
SECURITY_KEY_S2_ACCESS No

All Supports Command Class

Command Class

|

Version

| Not Included| Non-secure Included| S0 Included| S2 Included
---|---|---|---|---|---
Non-Secure| Secure| Non-Secure| Secure
COMMAND_CLASS_ZWAVEPLUS_INFO| 2| ●| ●| ●| | ●|
COMMAND_CLASS_SECURITY| 1| ●| ●| ●| | ●|
COMMAND_CLASS_SECURITY_2| 1| ●| ●| ●| | ●|
COMMAND_CLASS_TRANSPORT_SERVICE| 2| ●| ●| ●| | ●|
COMMAND_CLASS_VERSION| 3| ●| ●| | ●| | ●
COMMAND_CLASS_POWERLEVEL| 1| ●| ●| | ●| | ●
COMMAND_CLASS_ASSOCIATION| 2| ●| ●| | ●| | ●
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION| 3| ●| ●| | ●| | ●
COMMAND_CLASS_ASSOCIATION_GRP_INFO| 1| ●| ●| | ●| | ●
COMMAND_CLASS_MANUFACTURER_SPECIFIC| 2| ●| ●| ●| | | ●
COMMAND_CLASS_DEVICE_RESET_LOCALLY| 1| ●| ●| | ●| | ●
COMMAND_CLASS_BATTERY| 1| ●| ●| | ●| | ●
COMMAND_CLASS_WAKEUP| 2| ●| ●| | ●| | ●
COMMAND_CLASS_NOTIFICATION| 8| ●| ●| | ●| | ●
COMMAND_CLASS_SENSOR_BINARY| 2| ●| ●| | ●| | ●
COMMAND_CLASS_INDICATOR| 3| ●| ●| | ●| | ●
COMMAND_CLASS_CONFIGURATION| 4| ●| ●| | ●| | ●
COMMAND_CLASS_SUPERVISION| 1| ●| ●| ●| | ●|
COMMAND_CLASS_FIRMWARE_UPDATE_MD| 5| ●| ●| | ●| | ●

Notice 1: When device is included with S0 level, COMMAND_CLASS_MANUFACTURER_SPECIFIC is supported non-securely. And when device is included with S2 level, COMMAND_CLASS_MANUFACTURER_SPECIFIC is supported securely only.
Notice 2 : “●” – Indicates the corresponding command class is supported in NIF, Blank means the command class is not supported

Specifications

Power Supply CR 14250 × 1
Standby Current 2uA
Work Current(RF Tx) Up to 16mA
Operational Temperature 0 – 70℃
Communication frequency 868.40MHz, 869.85MHz (EU)

908.40MHz, 916.00MHz(US)

Range

| Up to 45m indoors (depending on the building structure), and 80m for outdoor open fields.

Up to 60m outdoors.

FCC

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance 20cm between the radiator & your body.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals