GENERAL INFORMATION

  • NO FROST
    SYMBOL

  • NOT SUITABLE FOR CHILDREN
    SYMBOL

  • OUTDOOR
    SYMBOL

  • DO NOT PUT UNDER WATER
    SYMBOL

  • DO NOT INSTALL IN THE VALVE BOX
    SYMBOL

  • TO BE INSTALLED OUTDOORS
    SYMBOL

SAFETY INSTRUCTION

Always keep the cover closed

SAFETY INSTRUCTION

FILTERED WATERFILTERED WATER

Use water from the mains tap or filter the water before using it

DESCRIPTION

DESCRIPTION

  1. Inspectable and washable filter
  2. Prise pour robinet 3/4” F
  3. Ring nut
  4. Liquid Crystal Display
  5. Back button
  6. Forward button
  7. Enter button
  8. Protective cover
  9. 3/4″ threaded male connector
  10. Click system Quick-Click male connector

BATTERY REPLACEMENT

BATTERY REPLACEMENT
BATTERY REPLACEMENT
BATTERY REPLACEMENT
BATTERY REPLACEMENT

BATTERY REPLACEMENT

Only use new 9 V Alkaline 6LR61 batteries, with an expiry date exceeding one year and that have never been used. Replace the battery at the beginning of each season. When the battery is completely flat, the water timer automatically stops its functions and closes the valve. Never replace the battery during irrigation, otherwise the water will continue to flow at the end of the cycle. After the battery has been replaced, reset the time. Programming is saved

INSTALLATION

INSTALLATION

Do not install the water timer inside valve boxes, below ground level or indoors. Do not use the water timer with operating pressures lower than 0.5 bar (7.3 psi) or higher than 10 bar (145 psi)

MAINTENANCE

MAINTENANCE

WARNING

Read this instruction manual carefully and keep it handy for future reference. This device has been designed and manufactured exclusively for the setting of watering time by adults with experience and knowledge. Any use other than that described in this manual is considered improper: the manufacturer acknowledges no liability for damages arising from improper use, which will also void the warranty. Do not power the water timer with sources other than those specified. It is good policy – when the water timer is used for the first time – to make certain that the programmes run correctly. Do not use the water timer with chemicals or liquids other than water

DISPOSAL

The symbol in question applied to the product or the packaging indicates that the product must not be considered as normal domestic waste, but must be taken to a special centre for the collection and recycling of waste electrical and electronic equipment. Take care to dispose of this product in the proper way; this will help to avoid the negative consequences that could arise from unsorted collection or dumping. For more detailed information on the recycling of this product, contact the municipal authority, the local refuse collection service or the dealer from whom the item was purchased.

CONDITIONS OF GUARANTE

This device is guaranteed for 3 years from the date of purchase as indicated by the invoice, bill or till receipt issued at the time of the transaction, which must be kept. Claber guarantees that the product is free of material or manufacturing defects. Within two years from the date of delivery to the consumer, Claber shall repair or replace any parts of this product found to be defective. The warranty is void in the event of:

  • Lack of proof of purchase (invoice, receipt or cash register receipt);
  • Use or maintenance different from what is specified;
  • Disassembly or tampering by unauthorised personnel;
  • Faulty installation of the product;
  • Damages from atmospheric agents or contact with chemical agents;

Claber accepts no liability for products that it has not manufactured, even if used in combination with its own products. The costs and the risks associated with shipment are met entirely by the owner. Assistance is provided by Claber authorized service centres.

KEY

INSTRUCTION

SETTINGS MODE

SETTINGS MODE
SETTINGS MODE
SETTINGS MODE

SETTINGS SEQUENCE

TIME PAGE
SETTINGS

TIME SETTING
SETTINGS

Holding the button pressed down, the time will progress faster
SETTINGS

PROGRAMMING PAGES

PROGRAMMING
PROGRAMMING
PROGRAMMING
PROGRAMMING

SETTING THE OPENING/CLOSING TIME

All programmes are set in the same way. Programme 2 cannot be programmed before setting Programme 1. The programmes must be set in sequence in time order within the same 24 hour period (e.g. 20:00 ĺ 21:00 pm OK ĺ 19:00 pm NO). The timer progresses automatically by 1 minute in both OPEN and CLOSED mode.

setting opening prog. 1

SETTING THE TIME
SETTING THE TIME
SETTING THE TIME

setting closing prog. 1

SETTING THE TIME
SETTING THE TIME

WEEKLY PROGRAM
WEEKLY PROGRAM

Press one of the arrows and position the cursor under the day you want to enable/disable. Press ENTER. To exit, position the cursor on EXIT and press ENTER. The days set apply to both lines.

INSTRUCTION

MANUAL

The watering duration cannot be changed

Press the left arrow to start irrigation (OPEN)

OPEN

I want to fully reset the timer. To fully reset the timer, press and hold the two arrow buttons together for at least 10 seconds. I want to delete a programme. To delete a programme, switch to CLOSED mode, press ENTER, then press the two arrows together.
How many minutes can an irrigation cycle be set to run for?
The total run time of all set irrigation programmes cannot exceed 23 hours and 59 minutes. The minimum time a programme can be set to is 1 minute. I want to set one irrigation cycle a day. To set one irrigation cycle a day, leave the second programme set to zero

 Declaration of Conformity