claber Aquauno Video-6 Plus Automatic Water Timer User Manual

June 3, 2024
claber

claber Aquauno Video-6 Plus Automatic Water Timer User Manual

INSTALLATION

Connect the timer to a tap and connect it to the system. Do not install the water timer inside valve boxes, below ground level or indoors. Do not use the water timer with chemicals or liquids other than water. Do not use the water timer with operating pressures lower than 0.5 bar (7.3 psi) or higher than 10 bar (145 psi).

For Aquauno Video-6 Plus

FITTING THE BATTERY

Press the two side buttons to open the timer and insert a new, branded 9V alkaline battery. Important: remember to turn on the water tap.
For Aquauno Video-6 Plus

As soon as the battery is connected, the display switches on, the valve runs a test cycle and the timer is set to 00:00.
For Aquauno Video-6 Plu

SETTING THE TIME

Press the middle ENTER button; “OK” will show on the screen to indicate that you can now enter the time. Press one of the arrows to set the time. Press and hold the arrow to speed up programming. Once you have entered the time, press ENTER to confirm.
- For Aquauno Video-6 Plus

PROGRAMMING

The timer can be used to set six daily irrigation cycles. Note: all programmes are set in the same way. Programmes must be entered in chronological order, within a 24-hour timeframe. The timer automatically advances by 1 minute with respect to the set time, both when OPEN and CLOSED. Note: if the symbolsymbol is flashing, this means the timer is waiting for a command. Press any button.

SETTING THE FIRST IRRIGATION CYCLE

Opening. After setting the time, press the right arrow to open the page for programme 1. The time 00:00 will show, preceded by a 1 (for programme 1). Press the middle ENTER button. You will see “OK” on the screen, meaning the opening time can be set using the arrows (e.g. 05:00). You will see a 1 (for programme 1) at the top of the screen. Confirm the time by pressing ENTER.
For Aquauno Video-6 Plus

SETTING THE FIRST IRRIGATION CYCLE – Closing. Press the right arrow to go to the page “CLOSED”. The timer automatically suggests a closing time 1 minute after the opening time set (e.g. opening at 05:00, suggested closing time 05:01). The time has a 1 before it (for programme 1). Press ENTER. You will see “OK” on the screen, meaning the closing time can be set using the arrows (e.g. 05:20). Confirm the time by pressing ENTER. To set the opening and closing times for the other programmes, repeat the procedure above.
For Aquauno Video-6 Plus

WEEKLY PROGRAMMING

Press the right arrow to open the weekly programming page. Press ENTER to select the days on which you want to irrigate. Use the arrows to position the cursor under the day you want to enable or disable and press ENTER.
Note: day 1 is the day the timer is set for the first time and is used as a reference. Example: If Thursday = day 1 and the intention is to skip watering on Friday, the day to deselect is day 2. Position the cursor under EXIT. Press ENTER to exit the weekly programming page.
- For Aquauno Video-6 Plus

MANUAL PROGRAMMING. Use the right arrow to open the manual programming page. Manual programming is useful for running an additional irrigation cycle, without deleting the programmes set. The timer automatically sets an irrigation run time of 15 minutes. Press ENTER. Use the left arrow to start irrigating. To interrupt the cycle before the end, press the right arrow and then ENTER. Use the right arrow to return to the initial page (day/time.
For Aquauno Video-6 Plus

DELETING A PROGRAMME. To delete a programme, go to CLOSED mode for the programme you want to delete. Press ENTER, then press the two arrows together.
For Aquauno Video-6 Plus \(

RESETTING THE TIMER. To fully reset the timer, press and hold the two arrow buttons together for at least 10 seconds, until 00:00 shows on the display.

RAIN SENSOR. You can connect the Rain Sensor (code 90915) to the timer by replacing the existing bridge connector installed with a specific connector. Irrigation will not start if the Rain Sensor container is full (at least 5 mm of rainfall). If there is an irrigation cycle in progress, this is stopped within a minute of the container being filled.
- For Aquauno Video-6 Plus

CLEANING AND MAINTENANCE

Clean the filter at the end of each season and check it regularly. Turn off the water tap and loosen the screw collar, turning anticlockwise. Loosen the 3/4″ screw collar of the tap connector, turning clockwise. Remove the filter. Rinse the filter clean under running water. After washing, reassemble all parts as before. To clean the internal components properly, please see the diagram showing the mechanical parts to be disassembled/ reassembled at the end of the season.
For Aquauno Video-6 Plus

At the end of the season, before the winter frosts, disconnect the timer from the tap, remove the battery and store the timer in a sheltered place, away from damp, where the temperature does not fall below 3°C.
For Aquauno Video-6 Plus

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals