The product name is SES24WH and it is manufactured by BEMKO Sp. z o.o. The company is located at ul. Bocznicowa 13, 05-850 Jawczyce and their website is www.bemko.eu. The product is designed for indoor use and operates on a power supply voltage of 230V~ 50Hz. It has a maximum load capacity of 800W for incandescent bulbs and 400W for energy-saving lamps and LED bulbs.

Product Usage Instructions

Before using the product, please ensure that the power supply voltage matches the specifications mentioned in the product information section. Here are the steps to use the product:

  1. Insert the SES24WH into a compatible power outlet.
  2. Screw in the desired light bulb (incandescent, energy-saving, or LED) into the SES24WH.
  3. Switch on the power supply.
  4. To turn on/off the light, use the appropriate switch on the lamp or use a remote control (if applicable).
  5. If you want to replace the bulb, switch off the power supply and wait for the bulb to cool down before unscrewing it from the SES24WH.

It is important to not exceed the maximum load capacity of the SES24WH to avoid any potential electrical hazards.

SPECIFICATION

Power source| 230V~ 50Hz| Detection range| 120º/360º|
---|---|---|---|---
Rated load max| 800W

400W

| Time delay| 5s, 30s, 1min, 3min,

5min, 8min

|
Power consumption| Pon: <0.5W| Working temperature| -20~+40°C|
Standby power| Psb: <0.5W| Working humidity| <93%RH|
Detection distance| 3m/6m max (<24°C)| Installation height| 1.8m~2.5m (wall)

2.2m~4m (ceiling)

|
Ambient light| 10LUX/2000LUX|
Detection moving speed| 0.6~1.5m/s|

FUNCTION

  • Can identify day and night automatically: when turn to SUN ((below is SUN)), it will work day and night, when turn it to MOON (above is moon), it will only work in the ambient light less than 10LUX. As for adjustment, please refer to the testing way.
  • SENS is adjustable: It can be adjusted according to using location. The detection distance of low sensitivity could be only 3m and high sensitivity could be 6m which fits for a large room.
  • Time-Delay is added continually: When it receives the second induction signal within the first induction, it will restart to time from the moment.

INSTALLATION NOTES

  • Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, lights, etc.
  • Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants, etc.
  • Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors, etc.BEMKO-SES24WH-Infrared-Motion-Sensor-fig-2

CONNECTION

Warning! Danger of death through electric shock!

  • must be installed by a professional electrician
  • to disconnect the power source
  • cover or shied any adjacent live components
  • check the power supply is disconnected
    • Connect the power and the load according to the connection-wire diagram.
    • Fix the bottom on the selected position with the inflated screw.
    • Switch on the power and test it.

TEST

  • Slide the LUX switch to the SUN position (below is SUN). Slide the SENS switch to maximum (below is the maximum). Adjust the TIME switch, slide 5”
  • Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After Warm-up 30sec, the sensor can start working. If the sensor receives the induction signal, the lamp will turn on. While there is no other induction signal anymore, the load should stop working within 5sec and the lamp would turn off.
  • Slide the LUX knob above on the minimum (moon). If the ambient light is more than 10LUX, the sensor would not work and the lamp stop working too. If the ambient light is less than 3LUX (darkness), the sensor would work. Under no induction signal condition, the sensor should stop working within 5sec.

NOTE:
When testing in daylight, please turn the LUX knob to the (SUN) position, otherwise the sensor lamp could not work! If the lamp is more than 60W, the distance between the lamp and the sensor should be 60cm at least.

MOST COMMON PROBLEMS AND SOLVING WAYS

  • The load does not work:
1. Please check if the connection of the power source and load is correct.
2. Please check if the load is good.
3. Please check if the settings of the working light correspond to the ambient light.
  • The sensitivity is poor:
1. Please check if there is any hindrance in front of the detector to affect it to receive the signals.
2. Please check if the ambient temperature is too high.
3. Please check if the induction signal source is in the detection field.
4. Please check if the installation height corresponds to the height required in the instruction.
5. Please check if the moving orientation is correct.
  • The sensor can not shut off the load automatically:
1. Please check if there is a continual signal in the detection field.
2. Please check if the time delay is set to the maximum position.